An HDPE end cap closes a line, and the cap you can use is decided by how the pipe is joined. We mould three types: socket fusion to dn63, electrofusion to dn315 and butt fusion to dn1600. Below are the full size tables for all three, the separate PE100 gas series, and an explanation of why the ranges stop where they do.

82 sizesfive end cap families
dn20–dn1600widest range
3fusion methods
SDR 11/17wall series

Three ways to close an HDPE pipe end

An end cap does one job: it closes the line so nothing gets in and nothing gets out. Which cap you can use is decided by the fusion method the line is built with, and that in turn decides the size you can reach. On this site the three ranges are quite different, and it is worth understanding why before you specify one.

End caps we mould, by fusion method
TypeFusion methodSize rangeWall seriesWhere it is used
Socket fusion end capSocket fusiondn20 – dn63SDR 11Service lines, irrigation, small-bore branches, threaded transitions
Electrofusion end capElectrofusiondn40 – dn315SDR 11Confined trenches, gas service lines, tie-ins where the pipe cannot move
Butt fusion end capButt fusiondn20 – dn1600SDR 11 / 17Mainlines, anything above dn315, pressure-tested lines

The three are not interchangeable on a joint: a cap has to be fused with the same method as the pipe end it meets, and it has to be the same SDR as that pipe. A dn110 SDR 11 pipe takes a dn110 SDR 11 electrofusion cap or a dn110 SDR 11 butt fusion cap, not an SDR 17 one.

Why the ranges stop where they do

The ranges above are the moulds we hold, not a statement about what is physically possible. Three things set the upper limit of each method.

  • Electrofusion stops at dn315. An electrofusion cap carries a heating coil moulded into the socket, with terminals on the outside. The coil length and the current it needs grow with the diameter, and so does the price of the mould. Above dn315 the economics do not work: a butt fusion cap of the same size is cheaper to make and cheaper to install, and it is a full-section weld.
  • Butt fusion runs to dn1600. Nothing electrical is inside the fitting, so the size is limited only by the machine that holds and faces the parts. This is why every large-diameter closure on the line is butt fusion.
  • Socket fusion stops at dn63. That is the ceiling of the socket fusion process itself, not of the cap. Above dn63 the heating tool cannot bring a socket up to temperature evenly across the wall.
A cap is a blind end, and a blind end takes thrust. The pressure acting on the closed face pushes the cap along the pipe, and the joint carries that load. On a large cap, or on a line that will be pressure tested, the end has to be restrained or the pipe has to be anchored and backfilled before test pressure goes on. This is about the installation, not the fitting: the same cap that holds for years in a buried line will move a free pipe end on test day.

Electrofusion end caps

The cap carries a coil socket, so it fuses to the pipe end without anything moving. Cut the pipe square, mark the insertion depth, clean and scrape the end, clamp if the line is under any load, and run the cycle from the control box. Because the pipe does not have to be pushed or rotated, this is the cap used where the line is already laid and the end cannot be lifted into a butt fusion machine.

The SDR 11 range is the water and industrial series; the dn50 – dn315 range below is the separate PE100 gas series, which uses a tick per series instead of an SDR column.

Electrofusion End Capdn40–dn315 · 11 sizes

Water and industrial series. dn315 is the top of the electrofusion range; above it, butt fusion is the only option.

Electrofusion End Cap – dn40–dn315 · 11 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn4011dn7511dn16011dn25011
dn5011dn9011dn20011dn31511
dn6311dn11011dn22511  

Electrofusion End Cap (gas series)dn50–dn315 · 10 sizes

Gas series, separate moulds. A dash in the SDR17 column means it is not made in that series, not that it cannot be made.

Electrofusion End Cap – dn50–dn315 · 10 sizes · PE100 gas series
SizeSDR11SDR17
dn50✓-
dn63✓-
dn75✓-
dn90✓-
dn110✓-
dn160✓-
dn200✓-
dn225✓-
dn250✓-
dn315✓-

Butt fusion end caps

A plain spigot with a domed closed end. It is faced and welded exactly like a pipe end, so the joint is a full-section weld and the cap is as strong as the pipe wall. This is the default above dn315, and the only option above dn630.

The water series runs dn20 – dn1600 and the gas series dn20 – dn630. Where the table shows 11/17 in the SDR column, the same body is moulded for both series.

Butt Fusion End Capdn20–dn1600 · 31 sizes

Water and industrial series. Where the SDR column reads 11/17, one body is moulded for both series; the three largest sizes are SDR 17 only.

Butt Fusion End Cap – dn20–dn1600 · 31 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn11011/17dn28011/17dn71011/17
dn2511dn12511/17dn31511/17dn80011/17
dn3211dn14011/17dn35511/17dn90011/17
dn4011dn16011/17dn40011/17dn100011/17
dn5011dn18011dn45011/17dn120017
dn6311dn20011/17dn50011/17dn140017
dn7511dn22511/17dn56011/17dn160017
dn9011/17dn25011/17dn63011/17  

Butt Fusion End Cap (gas series)dn20–dn630 · 24 sizes

Gas series, dn20 to dn630. Read across the SDR11 and SDR17 columns.

Butt Fusion End Cap – dn20–dn630 · 24 sizes · PE100 gas series
SizeSDR11SDR17SizeSDR11SDR17
dn20✓-dn180✓✓
dn25✓-dn200✓✓
dn32✓-dn225✓✓
dn40✓-dn250✓✓
dn50✓-dn280✓✓
dn63✓-dn315✓✓
dn75✓-dn355✓✓
dn90✓✓dn400✓✓
dn110✓✓dn450✓✓
dn125✓✓dn500✓✓
dn140✓✓dn560✓✓
dn160✓✓dn630✓✓

Socket fusion end caps

Small caps for service lines and branches: heat the pipe end and the cap socket on the heating tool, push together, hold. Six sizes only, dn20 to dn63, which is the whole socket fusion range.

Socket Fusion End Capdn20–dn63 · 6 sizes

Six sizes is the whole socket fusion range, so this table is the complete cap range below dn63.

Socket Fusion End Cap – dn20–dn63 · 6 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn3211dn5011
dn2511dn4011dn6311

Below dn63 most lines are service connections, so the cap is usually the last fitting on a branch rather than the end of a main.

How to cap an HDPE pipe

There are two different jobs here, and the words used for them get mixed up. One is a permanent closure: a fused end cap, part of the line for its life. The other is a temporary plug: something you take out again, used during testing, flushing or a shutdown.

Permanent closure: fuse an end cap

  1. Match the method and the SDR. The cap has to fuse with the pipe it meets: electrofusion cap on an electrofusion end, butt fusion cap on a butt fusion end, socket cap below dn63. Same SDR on both.
  2. Cut square and clean. A cap on a bevelled or dirty pipe end is a leak with a cover on it. For electrofusion, scrape the full insertion depth and mark it.
  3. Fuse to the machine chart, not to a number from memory. Heating time, changeover and cooling all follow the wall thickness.
  4. Restrain the end before pressure goes on. See the note above: a large cap on a free pipe end will move under test pressure.

Temporary closure: do not confuse it with a cap

  • Squeeze-off flattens the pipe between two bars to stop flow for a repair. It is a flow stop, not a closure: the pipe is pinched, not sealed with a fitting, and the squeezed section has to be cut out afterwards.
  • Mechanical test plugs are pushed into an open pipe end for a pressure test and pulled out afterwards. They need a clean, round bore and they are only as good as their seal.
  • A cap is not a test plug. Once a cap is fused it is permanent; if you need the line open again, use a flanged end or a plug, not a fused cap.
On gas lines, the cap is also a safety item. A gas service that is capped has to be provably sealed before it is abandoned, and the cap has to be traceable on the network record. Our gas series caps are moulded as a separate range for that reason: the same nominal size as the water series, a different product.

Ordering checklist for end caps

  • Pipe OD and SDR, not the nominal bore. dn110 SDR 11 is a different cap from dn110 SDR 17.
  • Fusion method: socket, electrofusion or butt. This is decided by the rest of the line, not by the cap.
  • Water/industrial or gas series. Same diameter, different range, different record.
  • Quantity and whether it is a line item or a spare. Caps are cheap to hold as spares and expensive to be short of on the day the trench closes.
  • If the end will be tested, say so: we will tell you what restraint the joint needs.

Frequently asked questions

Can I cap an HDPE pipe without a fusion machine?

Not permanently. HDPE is not glued or threaded; a mechanical plug pushed into the bore is a temporary closure for testing or flushing, and it will not hold line pressure over time. For a permanent closure the options are a fused end cap, or a flanged adaptor with a blind flange if the end has to be reopenable.

What size end cap do I need for a dn315 pipe?

dn315 at the same SDR as the pipe. At SDR 11 that is available in the electrofusion range (dn40 – dn315, at the top of it) and in the butt fusion range. Above dn315 only butt fusion is available.

Why is the electrofusion cap range smaller than the butt fusion one?

Because of the coil. An electrofusion cap has a heating coil moulded into the socket whose length and current demand grow with the diameter, so the tooling and the price climb faster than the size. Above dn315 a butt fusion cap does the same job for less.

Do I need to restrain an end cap?

The cap itself takes the pressure load on its closed face, and that load is transferred to the pipe through the joint. On a buried line the soil does the restraining. On a free end, or during a pressure test, the end has to be anchored or the cap has to be restrained. Tell us the test pressure and the pipe size and we will say what is needed.

Is an end cap the same as an end plug?

Not quite. An end cap is fused onto the pipe end and closes the line. An end plug is the closing piece of a saddle: it seals the outlet of a tapping saddle when the branch is not used. Both close something, but they sit in different places.