There are two ways to put a bolted flange on an HDPE line: a stub end with a separate steel backing ring, or a flange adaptor with the flange face moulded in. They look the same when the joint is made and they are not the same decision. This page compares them on the things that actually differ, with both size ranges printed.
The difference in one table
Both give you a bolted flange face on the end of a PE pipe. The difference is how many pieces it takes and where the bolt load goes.
| Stub end + backing ring | Flange adaptor | |
|---|---|---|
| Pieces per joint | Two: the PE stub end and a steel ring | One: the flange face is moulded into the adaptor |
| What carries the bolt load | The steel ring, which is separate from the PE | The moulded flange face and its steel insert |
| Fusion method | Butt fusion only | Electrofusion socket or butt fusion spigot |
| Size range we mould | dn40 – dn630 | dn40 – dn1600 (butt fusion), dn50 – dn800 (electrofusion) |
| Ring replaceable | Yes, without cutting the PE | No, it is part of the fitting |
| Parts to hold in store | Two lines: stub ends by size, rings by size and PN | One line |
| Assembly on site | Fuse the stub, slide the ring on, bolt up | Fuse the adaptor, bolt up |
| Where it is the better answer | Large sizes, corrosive surroundings, joints that will be opened | Small and mid sizes, speed, minimum parts |
Neither is stronger. Both present the same flange face to the gasket, and both are rated by the SDR of the PE and the PN of the ring. The choice is about parts, access and maintenance.
Why a stub end exists at all
A flange adaptor is the obvious solution: one part, one fusion, bolt it up. So why does anyone use two parts instead?
- Because the steel ring is the part that corrodes, and it can be changed. On an above-ground joint the PE outlives the ring by decades. With a stub end, the ring is slid off and replaced without cutting the pipe.
- Because at large diameters the moulded flange gets expensive. A dn630 flange adaptor has to mould a flange face into a thick-walled fitting. A dn630 stub end is a short spigot with a flare, and a steel ring does the rest.
- Because the ring can be a different material. The PE part never sees the bolt load, so the ring can be coated, galvanised or made in a grade chosen for the environment.
- Because the flare is a known quantity. A stub end seals on a flat flare face against the gasket, and the geometry does not depend on a moulded insert staying bonded.
The cost is one more part in the store and one more step on site. On a large or exposed joint, that is usually worth paying.
Size ranges side by side
The tables below are the full ranges, so you can see where the two products overlap and where only one of them exists. Above dn630 the stub end stops: that is where the flange adaptor takes over completely.
Butt Fusion Stub Enddn40–dn630 · 18 sizes
18 sizes, dn40 to dn630, SDR 11 and SDR 17. The stub itself, before the ring.
| Size | SDR11 | SDR17 | Size | SDR11 | SDR17 |
|---|---|---|---|---|---|
| dn40 | ✓ | - | dn225 | ✓ | ✓ |
| dn50 | ✓ | - | dn250 | ✓ | ✓ |
| dn63 | ✓ | - | dn315 | ✓ | ✓ |
| dn75 | ✓ | ✓ | dn355 | ✓ | ✓ |
| dn90 | ✓ | ✓ | dn400 | ✓ | ✓ |
| dn110 | ✓ | ✓ | dn450 | ✓ | ✓ |
| dn125 | ✓ | ✓ | dn500 | ✓ | ✓ |
| dn160 | ✓ | ✓ | dn560 | ✓ | ✓ |
| dn200 | ✓ | ✓ | dn630 | ✓ | ✓ |
Butt Fusion Flange Adaptordn40–dn1600 · 28 sizes
28 sizes, dn40 to dn1600. The one-piece alternative, and the only option above dn630.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn40 | 11 | dn140 | 11/17 | dn315 | 11/17 | dn710 | 11/17 |
| dn50 | 11 | dn160 | 11/17 | dn355 | 11/17 | dn800 | 11/17 |
| dn63 | 11 | dn180 | 11/17 | dn400 | 11/17 | dn900 | 11/17 |
| dn75 | 11 | dn200 | 11/17 | dn450 | 11/17 | dn1000 | 11/17 |
| dn90 | 11/17 | dn225 | 11/17 | dn500 | 11/17 | dn1200 | 11/17 |
| dn110 | 11/17 | dn250 | 11/17 | dn560 | 11/17 | dn1400# | 17 |
| dn125 | 11/17 | dn280 | 11/17 | dn630 | 11/17 | dn1600 | 17 |
Electrofusion Flange Adaptordn50–dn800 · 19 sizes
19 sizes, dn50 to dn800. One-piece with a coil socket, for trench work where the pipe cannot be lifted.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn50 | 11/9 | dn125 | 11 | dn315 | 11/17 | dn560 | 11/17 |
| dn63 | 11/9 | dn160 | 11/9 | dn355 | 11/17 | dn630 | 17 |
| dn75 | 11/9 | dn200 | 17/11/9 | dn400 | 11/17 | dn710 | 17 |
| dn90 | 11/9 | dn225 | 17/11 | dn450 | 11/17 | dn800 | 17 |
| dn110 | 11/9 | dn250 | 17/11/9 | dn500 | 11/17 |
Backing rings and PN rating
The ring is what makes a stub end joint work, and it is ordered as a separate line: by size and by PN. The PN follows the SDR of the PE: SDR 17 gives PN 10, SDR 11 gives PN 16, SDR 9 gives PN 20. Where a cell lists two values, both rings are available in that size.
Butt Fusion Flange Steel Ringdn40–dn1200 · 26 sizes
26 sizes, dn40 to dn1200. The ring for a butt fusion stub end or flange face.
| Size | PN Rating | Size | PN Rating | Size | PN Rating | Size | PN Rating |
|---|---|---|---|---|---|---|---|
| dn40 | 16 | dn140 | 16 | dn315 | 10/16 | dn710 | 10/16 |
| dn50 | 16 | dn160 | 16 | dn355 | 10/16 | dn800 | 10/16 |
| dn63 | 16 | dn180 | 16 | dn400 | 10/16 | dn900 | 10/16 |
| dn75 | 16 | dn200 | 10/16 | dn450 | 10/16 | dn1000 | 10/16 |
| dn90 | 16 | dn225 | 10/16 | dn500 | 10/16 | dn1200 | 10/16 |
| dn110 | 16 | dn250 | 10/16 | dn560 | 10/16 | ||
| dn125 | 16 | dn280 | 10/16 | dn630 | 10/16 |
Electrofusion Flange Steel Ringdn50–dn800 · 18 sizes
18 sizes, dn50 to dn800. The ring that goes behind an electrofusion flange adaptor face.
| Size | PN Rating | Size | PN Rating | Size | PN Rating | Size | PN Rating | Size | PN Rating |
|---|---|---|---|---|---|---|---|---|---|
| dn50 | 16/20 | dn110 | 16/20 | dn250 | 10/16/20 | dn450 | 10 | dn710 | 10 |
| dn63 | 16/20 | dn125 | 16 | dn315 | 10/16 | dn500 | 10/16 | dn800 | 10 |
| dn75 | 16/20 | dn160 | 16/20 | dn355 | 10/16 | dn560 | 10/16 | ||
| dn90 | 16/20 | dn200 | 10/16/20 | dn400 | 10/16 | dn630 | 10 |
What changes on site
| Step | Stub end + ring | Flange adaptor |
|---|---|---|
| 1 | Face and butt fuse the stub end to the pipe | Fuse the adaptor: coil socket or butt spigot |
| 2 | Let the joint cool fully before anything touches it | Same |
| 3 | Slide the steel ring over the spigot, flare towards the gasket | Nothing to assemble |
| 4 | Gasket, mating flange, bolts, tighten in sequence | Gasket, mating flange, bolts, tighten in sequence |
| 5 | Check the flare is centred in the ring before final torque | Check the faces are parallel before final torque |
Step 3 is where stub end joints go wrong: a ring fitted with the flare facing the wrong way looks assembled and will not seal. Step 5 is where flanged joints go wrong in general: uneven bolt torque distorts the face and the joint weeps.
Choosing between them
- Above dn630, it is a flange adaptor. The stub end range stops there. No decision to make.
- Above ground and exposed, lean to a stub end. The ring is the part that corrodes, and with a stub end it can be replaced without cutting the PE.
- In a trench where the pipe cannot be lifted, it is an electrofusion flange adaptor. A stub end is butt fusion only, so it needs the pipe in a machine.
- If stock and site speed matter more than service life, it is a flange adaptor. One part, one line in the store, one fusion.
- If the flange will be opened more than once, check the ring. Repeated bolt-up on a moulded flange face is where a flange adaptor shows its limit; a stub end's flare can be inspected and the ring changed.
Both are on the flange adaptor dimensions page as full tables, along with the installation side of the joint.
Frequently asked questions
Is a stub end the same as a flange adaptor?
No. A flange adaptor is one piece with a moulded flange face. A stub end is a short spigot with a rolled flare, and a separate steel backing ring pulls the flare against the mating flange. Both give the same bolted face.
Can I use a stub end above dn630?
Not from our range: the stub end stops at dn630. Above that a butt fusion flange adaptor is the option, and it runs to dn1600.
Do I need a ring with every stub end?
Yes. The stub end is PE only and cannot be bolted on its own. The ring is ordered separately by size and PN, and the drilling has to match the flange it bolts to.
Which is cheaper, a stub end or a flange adaptor?
It depends on the diameter. At small sizes a flange adaptor is usually the cheaper total because there is one part. At large sizes the stub end plus ring is often cheaper, because moulding a flange face into a large fitting costs more than making a ring. Ask for both against your size list.
Can a flange adaptor be electrofusion?
Yes. The electrofusion flange adaptor has a coil socket on the PE side and a moulded flange face, dn50 to dn800. That is the option in a trench where the pipe cannot go into a butt fusion machine.
- HDPE flange adaptor dimensions – both products as full tables, with installation
- HDPE fittings specifications – every family as a full table
- How HDPE pipes are joined – the fusion side of either joint
- HDPE to steel transition fittings – when the metal end is a weld rather than a flange
- SDR 11 HDPE fittings – the series that gives PN 16 on the ring