A water line asks three things of a fitting: it has to stay sealed underground, it must not affect the water, and it must carry the pressure class of the pipe. This page is the water-supply view of our range, from dn20 to dn1600, with the series selection, the families that carry most of a network, and the installation points that decide whether the line holds.
What a water line asks of a fitting
A potable water line has three requirements that decide the fitting: it has to stay sealed for decades underground, it must not affect the water, and it has to carry the pressure class of the pipe without becoming the weak point. PE100 meets all three, and the fitting is where the first and third are won or lost.
- Sealing. A fusion joint is not a seal in the usual sense: the two parts are melted into one continuous wall, so there is no gasket, no O-ring and nothing to age.
- Water quality. PE100 is inert and does not leach. Our fittings are moulded from the same compound as the pipe, so the bore is one material end to end. State at order if the project needs a potable water certificate, because that is a document, not a property of the fitting.
- Pressure. The fitting has to be the same SDR as the pipe, and the flange rings have to be the same PN. A dn315 SDR 11 coupling on an SDR 11 pipe is a PN 16 line; the same coupling on SDR 17 pipe is a mismatched joint.
The water range, by group
Our full range is 65 families, and 45 of them are the water and industrial range that runs from dn20 to dn1600; the other twenty are the separate PE100 gas series. Rather than print all forty-five tables here, this is the group view, so you can see what exists in each category and then go to the page that has the table.
| Family group | Families | Size range | Size entries | What it covers |
|---|---|---|---|---|
| Couplings | 4 | dn20–dn1400 | 98 | Straight and reducing, electrofusion, butt and socket |
| Tees | 7 | dn20–dn1600 | 260 | Equal, reducing and lateral |
| Elbows | 8 | dn20–dn1600 | 135 | 90° and 45°, plus the threaded elbows below dn63 |
| Reducers | 1 | dn50–dn630 | 78 | Butt fusion, 78 size combinations |
| Flange adaptors and rings | 4 | dn40–dn1600 | 91 | Electrofusion and butt fusion adaptors, with PN-rated steel rings |
| End caps | 3 | dn20–dn1600 | 48 | Closing a line or a branch |
| Saddles | 5 | dn63–dn315 | 51 | Branching off a main without cutting it |
| Threaded transitions | 4 | dn20–dn63 | 24 | Female and male threaded, for equipment connections |
| Ball valves | 3 | Ø32–Ø355 | 27 | With and without vent, standard or with booster |
| Steel-to-PE transitions | 6 | dn25–dn355 | 116 | For the riser where PE meets steel |
Full tables: tees · elbows · reducers · flange adaptors and stub ends · end caps · saddles, and every family on the specifications page.
Choosing the series for a water line
Water is where all three series are in use, and the choice is a pressure decision, not a preference.
| SDR series | SDR 17 | SDR 11 | SDR 9 |
|---|---|---|---|
| Nominal pressure | PN 10 | PN 16 | PN 20 |
| Typical service | Water distribution, gravity and low pressure | General pressure pipe, gas distribution | Higher pressure, industrial lines |
- Gravity and low-pressure distribution – SDR 17, PN 10. The usual choice for a municipal distribution main where the working pressure is well under 10 bar.
- General pressure pipe – SDR 11, PN 16. The default for pumped mains, and the series where our range is widest.
- Higher pressure and industrial lines – SDR 9, PN 20. Where the line runs above PN 16 or where surge is expected.
The families that carry most of a water network
Four fittings account for most of the joints in a distribution network: the coupling that joins pipe lengths, the tee that branches, the elbow that turns and the reducer that changes diameter. Their full tables are printed here because they are the ones ordered by the hundred; the rest are on the group-specific pages.
Electrofusion Straight Couplingdn20–dn1400 · 32 sizes
32 sizes, dn20 to dn1400. The widest electrofusion range we hold.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn20 | 11/9 | dn110 | 17/11/9 | dn280 | 17/11/9 | dn710 | 11/17 |
| dn25 | 11/9 | dn125 | 11/9 | dn315 | 17/11/9 | dn800 | 11/17 |
| dn32 | 11/9 | dn140 | 11/9 | dn355 | 11/17 | dn900 | 11 |
| dn40 | 11/9 | dn160 | 17/11/9 | dn400 | 11/17 | dn1000 | 11 |
| dn50 | 11/9 | dn180 | 11/9 | dn450 | 11/17 | dn900 | 17 |
| dn63 | 11/9 | dn200 | 17/11/9 | dn500 | 11/17 | dn1000 | 17 |
| dn75 | 11/9 | dn225 | 17/11/9 | dn560 | 11/17 | dn1200 | 11/17 |
| dn90 | 11/9 | dn250 | 17/11/9 | dn630 | 11/17 | dn1400 | 11/17 |
Electrofusion Equal Teedn25–dn630 · 25 sizes
25 sizes, dn25 to dn630.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn25 | 11/9 | dn110 | 17/11/9 | dn250 | 17/11/9 | dn630 | 11 |
| dn32 | 11/9 | dn125 | 11/9 | dn280 | 11# | dn450 | 17 |
| dn40 | 11/9 | dn140 | 11# | dn315 | 17/11/9 | dn500 | 17 |
| dn50 | 11/9 | dn160 | 17/11/9 | dn355 | 11/17 | dn630 | 17 |
| dn63 | 11/9 | dn180 | 11# | dn400 | 11 | ||
| dn75 | 11/9 | dn200 | 17/11/9 | dn450 | 11 | ||
| dn90 | 11/9 | dn225 | 17/11 | dn500 | 11 |
Butt Fusion 90° Elbowdn20–dn1600 · 31 sizes
31 sizes, dn20 to dn1600. Above dn900 this is the only elbow method.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn20 | 11 | dn110 | 11/17 | dn280 | 11/17 | dn710 | 11/17 |
| dn25 | 11 | dn125 | 11/17 | dn315 | 11/17 | dn800 | 11/17 |
| dn32 | 11 | dn140 | 11/17 | dn355 | 11/17 | dn900 | 11/17 |
| dn40 | 11 | dn160 | 11/17 | dn400 | 11/17 | dn1000 | 17 |
| dn50 | 11 | dn180 | 11/17 | dn450 | 11/17 | dn1200# | 11/17 |
| dn63 | 11 | dn200 | 11/17 | dn500 | 11/17 | dn1400# | 17 |
| dn75 | 11 | dn225 | 11/17 | dn560 | 11/17 | dn1600# | 17 |
| dn90 | 11/17 | dn250 | 11/17 | dn630 | 11/17 |
Butt Fusion Reducerdn50–dn630 · 78 sizes
78 combinations, dn50 to dn630. The largest single table in the water range.
| Size | SDR Series | Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|---|---|
| dn50 × 20 | 11 | dn110 × 63 | 11 | dn200 × 125 | 11 | dn315 × 225 | 11 |
| dn50 × 25 | 11 | dn110 × 75 | 11 | dn200 × 160 | 11 | dn315 × 250 | 11 |
| dn50 × 32 | 11 | dn110 × 90 | 11 | dn200 × 180 | 11 | dn315 × 280 | 11 |
| dn50 × 40 | 11 | dn125 × 63 | 11 | dn225 × 110 | 11 | dn355 × 250 | 11/17 |
| dn63 × 20 | 11 | dn125 × 75 | 11 | dn225 × 125 | 11 | dn355 × 315 | 11/17 |
| dn63 × 25 | 11 | dn125 × 90 | 11 | dn225 × 160 | 11 | dn400 × 160 | 11/17 |
| dn63 × 32 | 11 | dn125 × 110 | 11 | dn225 × 200 | 11 | dn400 × 200 | 11/17 |
| dn63 × 40 | 11 | dn140 × 110 | 11 | dn250 × 90 | 11 | dn400 × 250 | 11/17 |
| dn63 × 50 | 11 | dn160 × 50 | 11 | dn250 × 110 | 11 | dn400 × 315 | 11/17 |
| dn75 × 32 | 11 | dn160 × 63 | 11 | dn250 × 125 | 11 | dn400 × 355 | 11/17 |
| dn75 × 40 | 11 | dn160 × 75 | 11 | dn250 × 160 | 11 | dn450 × 250 | 11/17 |
| dn75 × 50 | 11 | dn160 × 90 | 11 | dn250 × 200 | 11 | dn450 × 315 | 11/17 |
| dn75 × 63 | 11 | dn160 × 110 | 11 | dn250 × 225 | 11 | dn450 × 400 | 11/17 |
| dn90 × 32 | 11 | dn160 × 125 | 11 | dn280 × 200 | 11/17 | dn500 × 315 | 11/17 |
| dn90 × 40 | 11 | dn160 × 140 | 11 | dn280 × 250 | 11/17 | dn500 × 400 | 11/17 |
| dn90 × 50 | 11 | dn180 × 160 | 11 | dn315 × 90 | 11/17 | dn500 × 450 | 11/17 |
| dn90 × 63 | 11 | dn200 × 63 | 11 | dn315 × 110 | 11/17 | dn630 × 400 | 11/17 |
| dn90 × 75 | 11 | dn200 × 75 | 11 | dn315 × 160 | 11 | dn630 × 450 | 11/17 |
| dn110 × 40 | 11 | dn200 × 90 | 11 | dn315 × 200 | 11 | dn630 × 500 | 11/17 |
| dn110 × 50 | 11 | dn200 × 110 | 11 |
Installation points that decide whether the line holds
- Same SDR on both sides of every joint. This is the single most common ordering error on a water line, and it does not show up until the pressure test.
- Scrape before you fuse. The oxide layer on PE pipe has to be removed over the full insertion depth of an electrofusion socket, and the pipe has to be round.
- Do not fuse wet, dirty or in wind. Water in the socket and dust on a heater plate both produce a joint that passes the visual check and fails in service.
- Restrain the ends. Caps, blind flanges and tees all take thrust; buried lines rely on the soil, test sections do not.
- Pressure test before backfill, and record the test. The joint cannot be inspected afterwards.
The step sequence for each fusion method, and the defects to look for, are on how HDPE pipes are joined.
Ordering checklist for a water project
- Pipe OD, SDR and working pressure for each line, not one figure for the project.
- Fusion method per size: socket below dn63, electrofusion or butt fusion above.
- Potable water documentation if the project requires it, asked for at quotation stage.
- Flange rings by PN, matched to the SDR of the adaptor, and the drilling standard of whatever they bolt to.
- Quantities per size: a water order is normally long on couplings and tees and short on everything else.
Frequently asked questions
Can PE fittings be used for drinking water?
Yes. PE100 is inert and does not leach, and our fittings are moulded from the same compound as the pipe, so the bore is one material throughout. If the project needs a potable water certificate or a migration test report, tell us at quotation stage: the fitting is the same, the paperwork is not automatic.
What SDR should a water main be?
SDR 17 (PN 10) for gravity and low-pressure distribution, SDR 11 (PN 16) for pumped mains, SDR 9 (PN 20) above PN 16 or where surge is expected. Both the pipe and the fitting have to be the same series.
Do I need electrofusion or butt fusion for a water line?
Either, above dn63: both give a full-section joint. Butt fusion suits long runs where the pipe can be moved into the machine; electrofusion suits trenches, tie-ins and confined sites. Below dn63 socket fusion is normal.
How large a water fitting can you supply?
dn1600 in butt fusion elbows, tees and flange adaptors, and dn1400 in the electrofusion coupling. Sizes above dn1200 are the ones to confirm on lead time before a tender closes.
Are the fittings the same as the ones in the gas range?
No, the gas range is a separate mould set with its own tables. The nominal sizes overlap, so a dn110 exists in both, but they are different products and only one of them is the gas one.
- HDPE fittings specifications – all 65 families as full tables
- SDR 11 HDPE fittings – the PN 16 series read family by family
- Tee dimensions · elbow dimensions · reducer size chart · flange adaptor dimensions
- Saddle sizes and end cap dimensions
- How HDPE pipes are joined
- HDPE fittings for mining and slurry lines – the same range where the duty is abrasion rather than pressure
- HDPE fittings for landfill leachate and gas collection – the same range where the duty is chemistry and settlement
- HDPE fittings for geothermal ground loops – the same range where the duty is thermal cycling
- HDPE fittings for drainage and stormwater – the same range loaded from the outside, by soil and groundwater
- HDPE fittings for marine outfalls and aquaculture – the same range at the coast, where UV and movement decide it














