Gas distribution is the application where PE took over first, and where the joint matters more than the fitting. We mould a separate PE100 gas range: twenty families from dn20 to dn630, electrofusion saddles for live mains, and the socket fusion service fittings below dn63. This page is the application view: what goes where in a gas network, and which table to read.

20gas families
dn20–dn630size range
dn63–dn400saddle mains
SDR 11/17wall series

Why gas networks are built in PE, and why they are fused

Polyethylene took over gas distribution for three reasons that all point the same way: it does not corrode, it is flexible enough to be coiled and pulled, and it can be joined into a continuous, leak-free line. A gas main has thousands of joints over its life, and every mechanical joint is a place where a seal can fail. Fusion removes the seal: the two parts become one piece of PE.

That is also why the gas range is a separate mould set from our water range. The fittings have the same nominal sizes and look similar, but they are moulded, tested and recorded as gas products, and they are listed in their own tables. Where a water coupling stops at one pressure class, the gas coupling is specified per series and the tables below show which series each size is made in.

Gas service changes the fitting, not just the label. The two things that matter on a gas line are that the joint is fully fused and that the record of it survives: which fitting, which batch, which fusion cycle, who did it. Ask us for the batch and traceability documentation with the order rather than after installation.

The gas range at a glance

Twenty gas families from dn20 to dn630, all moulded for SDR 11 and most of them for SDR 17 as well, plus the thirteen socket fusion families below dn63 that are used on service connections. The group table shows where the depth is.

Families in the PE100 gas series, grouped by function
Family groupFamiliesSize rangeSize entriesWhat it covers
Electrofusion couplings and reducers2dn20–dn40059Straight and reducing, the backbone of a gas main
Electrofusion tees2dn25–dn40072Equal and reducing; 56 branch combinations in the reducing tee
Electrofusion elbows2dn25–dn4003290° and 45°
Electrofusion end caps1dn50–dn31510Closing a service or a section
Electrofusion saddles3dn63–dn40033Clamp, end plug and bypass, mains to dn400
Electrofusion flange adaptors1dn110–dn4007Bolted connections to valves and steel
Butt fusion reducers and elbows3dn75–dn40081dn75 to dn400
Butt fusion tees2dn50–dn63088Reducing and equal, dn50 to dn630
Butt fusion end caps and stub ends2dn20–dn63042Closure and flanged termination
Condensate traps and crosses2dn63–dn40014Special items in the gas range

Every size in these families is on the fittings specifications page as a full table; the four most-used ones are printed below.

The four fittings a gas main uses most

If you are pricing a gas job, these are the four that set the quantity. All four are electrofusion: on a live or confined main the pipe cannot be pushed into a butt fusion machine, and electrofusion is the only method where nothing moves.

Electrofusion Straight Coupling (gas series)dn20–dn400 · 20 sizes

20 sizes, dn20 to dn400. The only gas family that covers the whole range in one table.

Electrofusion Straight Coupling – dn20–dn400 · 20 sizes · PE100 gas series
SizeSDR11SDR17SizeSDR11SDR17
dn20✓-dn140✓-
dn25✓-dn160✓✓
dn32✓-dn180✓-
dn40✓-dn200✓✓
dn50✓-dn225✓✓
dn63✓-dn250✓✓
dn75✓-dn280✓-
dn90✓-dn315✓✓
dn110✓✓dn355✓✓
dn125✓-dn400✓✓

Electrofusion Reducing Tee (gas series)dn25–dn400 · 56 sizes

56 combinations, dn25 to dn400. Branch sizes from dn20 up; this is the widest table in the gas range.

Electrofusion Reducing Tee – dn25–dn400 · 56 sizes · PE100 gas series
SizeSDR11SDR17SizeSDR11SDR17
dn25 × 20 × 25✓-dn125 × 90 × 125✓-
dn32 × 20 × 32✓-dn160 × 50 × 160✓-
dn32 × 25 × 32✓-dn160 × 63 × 160✓-
dn40 × 20 × 40✓-dn160 × 75 × 160✓-
dn40 × 25 × 40✓-dn160 × 90 × 160✓-
dn40 × 32 × 40✓-dn160 × 110 × 160✓-
dn50 × 25 × 50✓-dn200 × 63 × 200✓-
dn50 × 32 × 50✓-dn200 × 75 × 200✓-
dn50 × 40 × 50✓-dn200 × 90 × 200✓-
dn63 × 25 × 63✓-dn200 × 110 × 200✓-
dn63 × 32 × 63✓-dn200 × 160 × 200✓-
dn63 × 40 × 63✓-dn225 × 110 × 225✓-
dn63 × 50 × 63✓-dn225 × 160 × 225✓-
dn75 × 32 × 75✓-dn225 × 200 × 225✓-
dn75 × 40 × 75✓-dn250 × 90 × 250✓-
dn75 × 50 × 75✓-dn250 × 110 × 250✓-
dn75 × 63 × 75✓-dn250 × 160 × 250✓-
dn90 × 32 × 90✓-dn250 × 200 × 250✓-
dn90 × 40 × 90✓-dn315 × 110 × 315✓-
dn90 × 50 × 90✓-dn315 × 160 × 315✓-
dn90 × 63 × 90✓-dn315 × 200 × 315✓-
dn90 × 75 × 90✓-dn315 × 250 × 315✓-
dn110 × 32 × 110✓-dn355 × 200 × 355✓-
dn110 × 40 × 110✓-dn355 × 250 × 355✓-
dn110 × 50 × 110✓-dn355 × 315 × 355✓-
dn110 × 63 × 110✓-dn400 × 200 × 400✓-
dn110 × 75 × 110✓-dn400 × 250 × 400✓-
dn110 × 90 × 110✓-dn400 × 315 × 400✓-

Electrofusion Saddle Clamp (gas series)dn63–dn400 · 13 sizes

13 sizes, mains dn63 to dn400. Used for taking a service off a live main.

Electrofusion Saddle Clamp – dn63–dn400 · 13 sizes · PE100 gas series
SizeSDR11SDR17
dn63 × 32✓-
dn90 × 63✓-
dn110 × 63✓-
dn160 × 63✓-
dn200 × 63✓-
dn200 × 90✓-
dn250 × 63✓-
dn250 × 90✓-
dn250 × 110✓-
dn315 × 63✓-
dn315 × 90✓-
dn315 × 110✓-
dn400 × 250✓-

Electrofusion End Cap (gas series)dn50–dn315 · 10 sizes

10 sizes, dn50 to dn315. Read down the SDR11 column; a dash in SDR17 means not moulded in that series.

Electrofusion End Cap – dn50–dn315 · 10 sizes · PE100 gas series
SizeSDR11SDR17
dn50✓-
dn63✓-
dn75✓-
dn90✓-
dn110✓-
dn160✓-
dn200✓-
dn225✓-
dn250✓-
dn315✓-

Service connections, dn20 to dn63

Below dn63 the network is joined by socket fusion, and those thirteen families are not gas-specific: the same coupling or elbow is used on a water service. This is the part of the range where a gas service is actually built, from the main to the meter.

Socket fusion families used below dn63 (water and gas service alike)
Family groupFamiliesSize rangeSize entriesWhat it covers
Couplings2dn20–dn6321Straight and reducing, dn20 to dn63
Tees2dn20–dn6321Equal and reducing, dn20 to dn63
Elbows2dn20–dn631245° and 90°, dn20 to dn63
End caps1dn20–dn636Closing a service stub
Threaded transitions6dn20–dn6336Female and male threaded couplings, elbows and tees, for the meter connection

A service connection is normally: saddle on the main, socket or electrofusion tee on the branch, then PE pipe to the meter, ending in a threaded transition or a transition fitting. The threaded families at the bottom of the table are what the meter tail connects to, so the thread standard has to be stated on the order.

Do not mix series at the transition. A socket fusion joint needs both parts at the same wall series. Below dn63 the same socket is used for SDR 11 and SDR 17, which is why the small sizes are simpler to specify than the mains.

Which fusion method, at which point in the network

Method by position in the network
PositionTypical sizeMethodWhy
Main, new builddn90 – dn400Butt fusion or electrofusionButt where the pipe can be moved; electrofusion at tie-ins and in the trench
Main, repair or tie-indn63 – dn315ElectrofusionThe pipe cannot be lifted or rotated, so nothing can move during the weld
Service off a live maindn20 – dn63Electrofusion saddle + tappingThe main stays in service; the hole is made through the fused saddle
Service run to the meterdn20 – dn63Socket fusionSmall, fast, one heating tool, no control box
Connection to a steel riserdn25 – dn355Transition fittingThe PE end is fused, the steel end is threaded or welded

The two methods that matter on a gas network are electrofusion and butt fusion, and the choice is nearly always about access rather than about strength: both give a full-section joint. The step sequence for each is on how HDPE pipes are joined.

Ordering checklist for a gas job

  • State the series per size, not one SDR for the whole order. Gas mains are commonly SDR 11, but SDR 17 appears at the larger sizes and the tables show which.
  • Say where each fitting goes: main, service, or transition. It changes the method, and on a gas job it changes the documentation.
  • Threaded items need the thread standard. BSP and NPT are not interchangeable, and a meter tail will not adapt.
  • Traceability. Tell us at quotation stage if you need batch records or fusion data sheets with the delivery.
  • Valves. The PE ball valves in our range are listed separately, Ø32 to Ø355, and are ordered as valves rather than as fittings.

Frequently asked questions

Are your gas fittings different from the water fittings?

They are a separate mould set with their own tables, and they are listed as gas products. The nominal sizes overlap, so the same dn110 exists in both, but the fitting you get is the one from the gas range if you order the gas range.

Which SDR is used for gas mains?

SDR 11 is the common choice and it is the column that is filled for every size in the gas tables. SDR 17 appears in some families, mostly at the larger sizes, so read the SDR17 column per size rather than assuming the whole order is SDR 11.

Can a gas service be taken off a live main?

Yes, with an electrofusion saddle and a tapping tool: the saddle is fused to the main, then the main is drilled through the saddle outlet while it is still live. The bypass saddle goes further and keeps the section supplied while the branch is tied in.

What is the largest gas fitting you make?

dn630 in the butt fusion equal tee, and dn400 in the electrofusion coupling. Above dn400 the gas range switches to butt fusion, which is why the two largest families in the group table are butt fusion.

Do you supply the tapping tool?

Ask for it with the saddle order so the outlet size and the tool are matched. A tool of the wrong size leaves a step in the bore of the main, which is exactly what a pig or a scraper will catch on.