Gas distribution is the application where PE took over first, and where the joint matters more than the fitting. We mould a separate PE100 gas range: twenty families from dn20 to dn630, electrofusion saddles for live mains, and the socket fusion service fittings below dn63. This page is the application view: what goes where in a gas network, and which table to read.
Why gas networks are built in PE, and why they are fused
Polyethylene took over gas distribution for three reasons that all point the same way: it does not corrode, it is flexible enough to be coiled and pulled, and it can be joined into a continuous, leak-free line. A gas main has thousands of joints over its life, and every mechanical joint is a place where a seal can fail. Fusion removes the seal: the two parts become one piece of PE.
That is also why the gas range is a separate mould set from our water range. The fittings have the same nominal sizes and look similar, but they are moulded, tested and recorded as gas products, and they are listed in their own tables. Where a water coupling stops at one pressure class, the gas coupling is specified per series and the tables below show which series each size is made in.
The gas range at a glance
Twenty gas families from dn20 to dn630, all moulded for SDR 11 and most of them for SDR 17 as well, plus the thirteen socket fusion families below dn63 that are used on service connections. The group table shows where the depth is.
| Family group | Families | Size range | Size entries | What it covers |
|---|---|---|---|---|
| Electrofusion couplings and reducers | 2 | dn20–dn400 | 59 | Straight and reducing, the backbone of a gas main |
| Electrofusion tees | 2 | dn25–dn400 | 72 | Equal and reducing; 56 branch combinations in the reducing tee |
| Electrofusion elbows | 2 | dn25–dn400 | 32 | 90° and 45° |
| Electrofusion end caps | 1 | dn50–dn315 | 10 | Closing a service or a section |
| Electrofusion saddles | 3 | dn63–dn400 | 33 | Clamp, end plug and bypass, mains to dn400 |
| Electrofusion flange adaptors | 1 | dn110–dn400 | 7 | Bolted connections to valves and steel |
| Butt fusion reducers and elbows | 3 | dn75–dn400 | 81 | dn75 to dn400 |
| Butt fusion tees | 2 | dn50–dn630 | 88 | Reducing and equal, dn50 to dn630 |
| Butt fusion end caps and stub ends | 2 | dn20–dn630 | 42 | Closure and flanged termination |
| Condensate traps and crosses | 2 | dn63–dn400 | 14 | Special items in the gas range |
Every size in these families is on the fittings specifications page as a full table; the four most-used ones are printed below.
The four fittings a gas main uses most
If you are pricing a gas job, these are the four that set the quantity. All four are electrofusion: on a live or confined main the pipe cannot be pushed into a butt fusion machine, and electrofusion is the only method where nothing moves.
Electrofusion Straight Coupling (gas series)dn20–dn400 · 20 sizes
20 sizes, dn20 to dn400. The only gas family that covers the whole range in one table.
| Size | SDR11 | SDR17 | Size | SDR11 | SDR17 |
|---|---|---|---|---|---|
| dn20 | ✓ | - | dn140 | ✓ | - |
| dn25 | ✓ | - | dn160 | ✓ | ✓ |
| dn32 | ✓ | - | dn180 | ✓ | - |
| dn40 | ✓ | - | dn200 | ✓ | ✓ |
| dn50 | ✓ | - | dn225 | ✓ | ✓ |
| dn63 | ✓ | - | dn250 | ✓ | ✓ |
| dn75 | ✓ | - | dn280 | ✓ | - |
| dn90 | ✓ | - | dn315 | ✓ | ✓ |
| dn110 | ✓ | ✓ | dn355 | ✓ | ✓ |
| dn125 | ✓ | - | dn400 | ✓ | ✓ |
Electrofusion Reducing Tee (gas series)dn25–dn400 · 56 sizes
56 combinations, dn25 to dn400. Branch sizes from dn20 up; this is the widest table in the gas range.
| Size | SDR11 | SDR17 | Size | SDR11 | SDR17 |
|---|---|---|---|---|---|
| dn25 × 20 × 25 | ✓ | - | dn125 × 90 × 125 | ✓ | - |
| dn32 × 20 × 32 | ✓ | - | dn160 × 50 × 160 | ✓ | - |
| dn32 × 25 × 32 | ✓ | - | dn160 × 63 × 160 | ✓ | - |
| dn40 × 20 × 40 | ✓ | - | dn160 × 75 × 160 | ✓ | - |
| dn40 × 25 × 40 | ✓ | - | dn160 × 90 × 160 | ✓ | - |
| dn40 × 32 × 40 | ✓ | - | dn160 × 110 × 160 | ✓ | - |
| dn50 × 25 × 50 | ✓ | - | dn200 × 63 × 200 | ✓ | - |
| dn50 × 32 × 50 | ✓ | - | dn200 × 75 × 200 | ✓ | - |
| dn50 × 40 × 50 | ✓ | - | dn200 × 90 × 200 | ✓ | - |
| dn63 × 25 × 63 | ✓ | - | dn200 × 110 × 200 | ✓ | - |
| dn63 × 32 × 63 | ✓ | - | dn200 × 160 × 200 | ✓ | - |
| dn63 × 40 × 63 | ✓ | - | dn225 × 110 × 225 | ✓ | - |
| dn63 × 50 × 63 | ✓ | - | dn225 × 160 × 225 | ✓ | - |
| dn75 × 32 × 75 | ✓ | - | dn225 × 200 × 225 | ✓ | - |
| dn75 × 40 × 75 | ✓ | - | dn250 × 90 × 250 | ✓ | - |
| dn75 × 50 × 75 | ✓ | - | dn250 × 110 × 250 | ✓ | - |
| dn75 × 63 × 75 | ✓ | - | dn250 × 160 × 250 | ✓ | - |
| dn90 × 32 × 90 | ✓ | - | dn250 × 200 × 250 | ✓ | - |
| dn90 × 40 × 90 | ✓ | - | dn315 × 110 × 315 | ✓ | - |
| dn90 × 50 × 90 | ✓ | - | dn315 × 160 × 315 | ✓ | - |
| dn90 × 63 × 90 | ✓ | - | dn315 × 200 × 315 | ✓ | - |
| dn90 × 75 × 90 | ✓ | - | dn315 × 250 × 315 | ✓ | - |
| dn110 × 32 × 110 | ✓ | - | dn355 × 200 × 355 | ✓ | - |
| dn110 × 40 × 110 | ✓ | - | dn355 × 250 × 355 | ✓ | - |
| dn110 × 50 × 110 | ✓ | - | dn355 × 315 × 355 | ✓ | - |
| dn110 × 63 × 110 | ✓ | - | dn400 × 200 × 400 | ✓ | - |
| dn110 × 75 × 110 | ✓ | - | dn400 × 250 × 400 | ✓ | - |
| dn110 × 90 × 110 | ✓ | - | dn400 × 315 × 400 | ✓ | - |
Electrofusion Saddle Clamp (gas series)dn63–dn400 · 13 sizes
13 sizes, mains dn63 to dn400. Used for taking a service off a live main.
| Size | SDR11 | SDR17 |
|---|---|---|
| dn63 × 32 | ✓ | - |
| dn90 × 63 | ✓ | - |
| dn110 × 63 | ✓ | - |
| dn160 × 63 | ✓ | - |
| dn200 × 63 | ✓ | - |
| dn200 × 90 | ✓ | - |
| dn250 × 63 | ✓ | - |
| dn250 × 90 | ✓ | - |
| dn250 × 110 | ✓ | - |
| dn315 × 63 | ✓ | - |
| dn315 × 90 | ✓ | - |
| dn315 × 110 | ✓ | - |
| dn400 × 250 | ✓ | - |
Electrofusion End Cap (gas series)dn50–dn315 · 10 sizes
10 sizes, dn50 to dn315. Read down the SDR11 column; a dash in SDR17 means not moulded in that series.
| Size | SDR11 | SDR17 |
|---|---|---|
| dn50 | ✓ | - |
| dn63 | ✓ | - |
| dn75 | ✓ | - |
| dn90 | ✓ | - |
| dn110 | ✓ | - |
| dn160 | ✓ | - |
| dn200 | ✓ | - |
| dn225 | ✓ | - |
| dn250 | ✓ | - |
| dn315 | ✓ | - |
Service connections, dn20 to dn63
Below dn63 the network is joined by socket fusion, and those thirteen families are not gas-specific: the same coupling or elbow is used on a water service. This is the part of the range where a gas service is actually built, from the main to the meter.
| Family group | Families | Size range | Size entries | What it covers |
|---|---|---|---|---|
| Couplings | 2 | dn20–dn63 | 21 | Straight and reducing, dn20 to dn63 |
| Tees | 2 | dn20–dn63 | 21 | Equal and reducing, dn20 to dn63 |
| Elbows | 2 | dn20–dn63 | 12 | 45° and 90°, dn20 to dn63 |
| End caps | 1 | dn20–dn63 | 6 | Closing a service stub |
| Threaded transitions | 6 | dn20–dn63 | 36 | Female and male threaded couplings, elbows and tees, for the meter connection |
A service connection is normally: saddle on the main, socket or electrofusion tee on the branch, then PE pipe to the meter, ending in a threaded transition or a transition fitting. The threaded families at the bottom of the table are what the meter tail connects to, so the thread standard has to be stated on the order.
Which fusion method, at which point in the network
| Position | Typical size | Method | Why |
|---|---|---|---|
| Main, new build | dn90 – dn400 | Butt fusion or electrofusion | Butt where the pipe can be moved; electrofusion at tie-ins and in the trench |
| Main, repair or tie-in | dn63 – dn315 | Electrofusion | The pipe cannot be lifted or rotated, so nothing can move during the weld |
| Service off a live main | dn20 – dn63 | Electrofusion saddle + tapping | The main stays in service; the hole is made through the fused saddle |
| Service run to the meter | dn20 – dn63 | Socket fusion | Small, fast, one heating tool, no control box |
| Connection to a steel riser | dn25 – dn355 | Transition fitting | The PE end is fused, the steel end is threaded or welded |
The two methods that matter on a gas network are electrofusion and butt fusion, and the choice is nearly always about access rather than about strength: both give a full-section joint. The step sequence for each is on how HDPE pipes are joined.
Ordering checklist for a gas job
- State the series per size, not one SDR for the whole order. Gas mains are commonly SDR 11, but SDR 17 appears at the larger sizes and the tables show which.
- Say where each fitting goes: main, service, or transition. It changes the method, and on a gas job it changes the documentation.
- Threaded items need the thread standard. BSP and NPT are not interchangeable, and a meter tail will not adapt.
- Traceability. Tell us at quotation stage if you need batch records or fusion data sheets with the delivery.
- Valves. The PE ball valves in our range are listed separately, Ø32 to Ø355, and are ordered as valves rather than as fittings.
Frequently asked questions
Are your gas fittings different from the water fittings?
They are a separate mould set with their own tables, and they are listed as gas products. The nominal sizes overlap, so the same dn110 exists in both, but the fitting you get is the one from the gas range if you order the gas range.
Which SDR is used for gas mains?
SDR 11 is the common choice and it is the column that is filled for every size in the gas tables. SDR 17 appears in some families, mostly at the larger sizes, so read the SDR17 column per size rather than assuming the whole order is SDR 11.
Can a gas service be taken off a live main?
Yes, with an electrofusion saddle and a tapping tool: the saddle is fused to the main, then the main is drilled through the saddle outlet while it is still live. The bypass saddle goes further and keeps the section supplied while the branch is tied in.
What is the largest gas fitting you make?
dn630 in the butt fusion equal tee, and dn400 in the electrofusion coupling. Above dn400 the gas range switches to butt fusion, which is why the two largest families in the group table are butt fusion.
Do you supply the tapping tool?
Ask for it with the saddle order so the outlet size and the tool are matched. A tool of the wrong size leaves a step in the bore of the main, which is exactly what a pig or a scraper will catch on.
- HDPE saddle sizes – clamp, bypass and end plug, with branch sizes
- SDR 11 HDPE fittings – the same range read the other way, by wall series
- HDPE fittings specifications – every gas family as a full table
- HDPE to steel transition fittings – for the riser at the end of a PE main
- How HDPE pipes are joined – electrofusion and socket fusion step by step
- HDPE fittings for mining and slurry lines – the same butt fusion range at tailings duty
- HDPE fittings for landfill leachate and gas collection – the gas header, and the spec it needs