Application
Application decides the fitting, not the other way round
PE100 is one material, but a joint carrying drinking water and a joint carrying gas are not asked to prove the same things. A water leak means an interruption and a repair crew. A gas leak means an evacuation. The pipe and the fitting may look identical on the pallet; the acceptance criteria behind them do not.
That difference runs through four decisions: what the pipe carries, at what pressure, under which standard, and how the joint is made. The eight duties below are grouped by those four, so you can move from a service condition to a fitting family without guessing. Each group links to the detailed page for that application.

01
Municipal water supply, gas supply and agriculture etc

02
Commercial & Residential water supply

03
Industrial liquids transportation

04
Sewage treatment

05
Food and chemical industry

06
Replacement of cement pipes and steel pipes

07
Argillaceous silt, mud transportation

08
Garden green pipe networks
Four questions that narrow the range
Before the catalogue, four answers. They eliminate most of the range on their own, and they are the same four a quotation needs.
1. What is in the pipe, and at what temperature
PE pressure ratings are quoted at 20 degC. Above roughly 30 degC the allowable pressure falls, and a line running hot water or a hot industrial effluent cannot use the same SDR as a cold-water main at the same pressure. Chemical resistance is a separate question again: PE handles most salts, acids and alkalis, but not aromatic solvents or strong oxidisers, and no fitting choice fixes a material that the medium attacks.
2. What pressure class the design asks for
SDR fixes wall thickness, and wall thickness fixes the pressure class: for PE100 water service, SDR11 corresponds to PN16, SDR17 to PN10 and SDR26 to PN6.3. The fitting must match the pipe SDR, not merely the outside diameter. An SDR11 socket pushed onto an SDR17 pipe leaves a gap at the fusion interface, and an electrofusion fitting will wire up and cycle without ever developing interface pressure.
3. Which standard system the project works to
Water and gas run on separate standards even where the products are interchangeable. Water service is normally specified to ISO 4427 or EN 12201; gas to ISO 4437 or EN 1555. The products may be dimensionally identical, but the test regime, the documentation and often the marking are not. Mixing the two systems inside one project is the single most common reason a delivery is rejected at site.
4. How the joint will actually be made
Butt fusion needs room to move the pipe and a machine that can face and align it. Electrofusion needs a power supply, a clean scraping tool and a fitting that fits the trench. Socket fusion is for small diameters where a hand tool is faster than a machine. In a narrow utility trench under a pavement, that constraint alone usually decides between electrofusion and butt fusion, whatever the pressure class says.
| Duty | Typical DN | SDR | Governing standard | Joint normally used | Fitting that leads |
|---|---|---|---|---|---|
| Municipal water mains | DN90 - DN800 | SDR11 - SDR17 | ISO 4427 / EN 12201 | Butt fusion | Equal tee, flange adaptor |
| Building and residential water | DN20 - DN160 | SDR11 - SDR13.6 | ISO 4427 | Socket and electrofusion | Elbow, coupling, reducer |
| Gas distribution | DN32 - DN400 | SDR11 | ISO 4437 / EN 1555 | Electrofusion | Electrofusion saddle, ball valve |
| Irrigation and agriculture | DN50 - DN630 | SDR17 - SDR26 | ISO 4427 | Butt fusion | Ball valve, end cap, saddle |
| Industrial and mining slurry | DN200 - DN1000 | SDR11 - SDR17 | ISO 4427 / project spec | Butt fusion | Thick-wall elbow, equal tee |
| Sewage and drainage | DN110 - DN1200 | SDR17 - SDR26 | ISO 4427 / EN 12666 | Butt fusion | Inspection tee, saddle |
| Food and chemical | DN25 - DN315 | SDR11 | ISO 4427, potable grades | Electrofusion | Full-port ball valve, coupling |
| Cement and steel replacement | DN110 - DN800 | SDR11 - SDR17 | ISO 4427 | Butt fusion plus flange | Flange adaptor, steel transition |
Ranges are the diameters commonly supplied for each duty, not a limit of the product range. Pressure classes follow the SDR to class relationship for PE100 water service; gas design pressures are set by the network operator.
Where the same fitting is specified differently
Three products appear in almost every application list. Each one is bought to a different specification depending on what it is joining.
The electrofusion coupling
In water, acceptance is usually a pressure test on the completed section. In gas, every joint carries a record: operator, machine, batch, fusion time and the bar code that traces the coil to its production lot. The fitting is the same shape; the traceability that travels with it is not.
The ball valve
A gas valve needs a vent or a tapping point, a stem that can be operated under the road with a key, and a body that will not creep under continuous line pressure. An irrigation valve needs a low head loss and a handle that a field operator can turn by hand. Both are PE ball valves; neither is a substitute for the other.
The saddle
Mechanical saddles with a rubber seal are common in irrigation, where a clamp and a tapped outlet are enough. Gas services use an electrofusion saddle with a fusion coil around the outlet, because a mechanical seal in a buried gas main is a leak waiting for a settling season. The tapping method decides which one is permissible, not the diameter.

Three mistakes that survive the drawing stage
The errors that reach site are rarely about pressure class. They are about transferring the habits of one application into another.
Water acceptance applied to gas. A hydrostatic test passes a joint that has no record behind it. On a gas network, a joint without a record is a joint that cannot be investigated later, and the operator will reject the section regardless of the test result.
Low-pressure duty used to justify a mismatched fitting. A SDR26 irrigation main does not accept a fitting bored for SDR11 wall sections. The fusion zone is designed around a specific wall thickness range, and the visible fit at the socket mouth does not tell you whether the coil is in contact with the pipe.
Two standards in one delivery. Pipe to EN 12201 with fittings marked to EN 1555, or a flange drilled to a different table than the mating valve. Each item passes on its own; the assembly does not. Ask for one standard reference on the whole package and hold the supplier to it.
From the duty to a quotation
The four answers above are also the four things a price depends on: the medium fixes the material grade, the pressure class fixes the wall and therefore the fitting weight, the standard fixes the test and documentation package, and the joint method fixes whether the item is an electrofusion or a butt fusion product. Send those plus quantities and a delivery port, and the quotation comes back with a size list rather than a question.
If the range itself is still open, start with the HDPE fittings specification tables, which list every series by diameter and wall thickness. For the two largest application groups see HDPE gas fittings and HDPE water supply fittings. For agriculture see HDPE irrigation fittings, and where a PE line has to meet steel or a chamber wall, HDPE to steel transition fittings.
Installation sequence, trench conditions and the checks that decide whether a joint is accepted are set out in the HDPE fittings installation guide. If the project is already at quotation stage, send the duty, diameter, SDR, standard and quantity through the quotation form.
Application guides, one per duty
Each of these pages is written for one duty rather than one product, because the duty is what changes the fitting. What follows is the load each one is designed against, which is a faster way to find the right page than reading a product list.
- HDPE fittings for gas distribution – designed against leakage: fusion joints, SDR 11, and the EN 1555 requirements that go with them.
- HDPE fittings for water supply – designed against pressure and potable compliance, from the service connection to the trunk main.
- HDPE fittings for irrigation – designed against cost per hectare and against a line that is drained and refilled every season.
- HDPE fittings for mining and mineral processing – designed against abrasion: velocity windows, bend geometry and the point where PE stops being the right answer.
- HDPE fittings for landfill leachate and gas collection – designed against settlement and permeation, where a joint cannot be reached once the cell is capped.
- HDPE fittings for geothermal ground loops – designed against thermal cycling and a pre-grouting test that is the only chance to find a bad joint.
- HDPE fittings for drainage and stormwater – designed from the outside in: ring stiffness, embedment class and buoyancy instead of pressure rating.
- HDPE fittings for marine outfalls and aquaculture – designed against ultraviolet above the waterline and movement below it.