An irrigation network is long, shallow and has hundreds of small joints, so it is built almost entirely from socket fusion fittings below dn63. This page covers the three fittings a lateral actually uses, the saddle that branches a buried main without cutting it, and the valves and transitions at the pump and the outlet.

dn20–dn63lateral fittings
dn63–dn400saddle mains
13socket fusion families
SDR 11wall series

Why irrigation runs on PE

An irrigation network is long, shallow and cheap per metre, and it has to survive sun, frost and being driven over. PE wins on all four counts: it comes in coils so a lateral can be run in one piece, it takes a freeze without splitting, it does not corrode, and the fittings below dn63 are socket fusion, which needs a heating tool rather than a fusion machine.

The other reason is the joint. A buried drip or sprinkler network has hundreds of small connections, and a mechanical fitting at each one is hundreds of places to leak. Fusion removes the leak path, and at these diameters it is fast: one heating tool, no control box, no data logging.

Irrigation is where the small-diameter range earns its place. Socket fusion stops at dn63, and so do thirteen of our families. Above dn63 an irrigation main moves to electrofusion or butt fusion, and the fittings become the same ones a water main uses.

From the pump to the dripper

An irrigation system is four layers of pipe, each with a different fitting problem.

The layers of an irrigation network
LayerTypical sizeMain fittingsMethod
Pump main and headworksdn90 – dn315Flange adaptors, tees, elbows, reducersButt fusion, flanged at the pump
Distribution maindn63 – dn200Tees, reducers, saddles, valvesButt fusion or electrofusion
Lateral / sub-maindn32 – dn63Tees, elbows, end caps, threaded transitionsSocket fusion
Dripper line take-offdn16 – dn32Saddles, small tees, connectorsSocket fusion, or the dripper supplier's own connectors

The layer that decides the order is the lateral: it is the longest total length and the largest number of joints, and it is almost always socket fusion.

The three fittings a lateral uses

Below dn63 an irrigation lateral is built from couplings, tees and elbows, with an end cap at the far end. All three are six to fifteen sizes, all SDR 11, all socket fusion.

Socket Fusion Couplingdn20–dn63 · 6 sizes

6 sizes, dn20 to dn63. One piece per pipe joint, so the quantity is roughly the number of coil ends.

Socket Fusion Coupling – dn20–dn63 · 6 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn3211dn5011
dn2511dn4011dn6311

Socket Fusion Teedn20–dn63 · 6 sizes

6 sizes, dn20 to dn63. Equal tee; for a smaller branch use the reducing tee.

Socket Fusion Tee – dn20–dn63 · 6 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn3211dn5011
dn2511dn4011dn6311

Socket Fusion 90° Elbowdn20–dn63 · 6 sizes

6 sizes, dn20 to dn63. A 45° version is available in the same range.

Socket Fusion 90° Elbow – dn20–dn63 · 6 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn3211dn5011
dn2511dn4011dn6311

Socket Fusion End Capdn20–dn63 · 6 sizes

6 sizes, dn20 to dn63. One per lateral that dead-ends.

Socket Fusion End Cap – dn20–dn63 · 6 sizes
SizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn2011dn3211dn5011
dn2511dn4011dn6311

Reducing tees and reducing couplings in the same range: 15 combinations each, dn25 to dn63, in the full specifications.

Branching off a buried main

A saddle takes a lateral off a distribution main without cutting it, and on an irrigation system that is how a new field is added to an existing main. The main does not have to be drained, and the branch can be tapped live.

Electrofusion Saddle Clampdn63–dn400 · 13 sizes

13 sizes, mains dn63 to dn400 with dn32 to dn250 branches.

Electrofusion Saddle Clamp – dn63–dn400 · 13 sizes · PE100 gas series
SizeSDR11SDR17
dn63 × 32✓-
dn90 × 63✓-
dn110 × 63✓-
dn160 × 63✓-
dn200 × 63✓-
dn200 × 90✓-
dn250 × 63✓-
dn250 × 90✓-
dn250 × 110✓-
dn315 × 63✓-
dn315 × 90✓-
dn315 × 110✓-
dn400 × 250✓-

Below dn63 the main is normally small enough that a socket fusion tee is cheaper and faster than a saddle. Above dn63 the saddle wins because it avoids cutting and re-joining the main.

Valves and the pump connection

Two places in an irrigation network need something other than a fusion joint: the pump headworks and the control valves.

  • At the pump the connection has to be demountable, so it is flanged: a flange adaptor on the PE, a backing ring, and the pump's own flange. See flange adaptor dimensions.
  • In the line a PE ball valve is fused in like a fitting. Our range covers Ø32 to Ø355, standard or with a single or double vent, and it is ordered as a valve rather than as a fitting.
  • At the field outlet the line usually ends in a threaded transition, so the hydrant or the air valve can be screwed on. Female and male threaded couplings, elbows and tees run dn20 to dn63.
Valve bodies are the one place to check the series. A ball valve has to match the SDR of the pipe it is fused into, and the vent versions exist because an irrigation line drained at the low end needs air in at the high end.

Ordering checklist for an irrigation project

  • Split the order by layer: main, sub-main, lateral. The fittings do not overlap much between layers.
  • Count by joint, not by metre. A lateral needs one coupling per coil end and one tee per take-off; the pipe length does not tell you that.
  • Say if the main is live when the branch is added. If it is, it is a saddle and a tapping tool, not a tee.
  • State the thread standard for outlet transitions: BSP and NPT are not interchangeable.
  • UV exposure. PE in the open degrades in sunlight; if a lateral runs above ground, say so and we will quote the black compound rather than assume.

Frequently asked questions

What size HDPE pipe do I need for irrigation?

Laterals are normally dn32 to dn63 and sub-mains dn63 to dn200, with the pump main at dn90 to dn315. The lateral is decided by the flow each dripper line needs, not by the field size, so size from the hydraulic design rather than from the area.

Can I add a branch to a buried irrigation main without digging it up?

Yes, with an electrofusion saddle and a tapping tool: the saddle is fused to the outside of the main and the main is drilled through it. The main does not have to be drained, which is why saddles are used for field extensions.

Do you supply dripper line and drippers?

No. Our range is the PE pipe fittings: couplings, tees, elbows, reducers, saddles, valves and transitions from dn20 to dn1600. Dripper line, emitters and filters come from the irrigation equipment supplier, and the connection between the two is normally a socket fusion tee or a threaded transition.

Is socket fusion strong enough for a pressurised irrigation main?

Socket fusion gives a full-section joint, so the joint is not the weak point. Below dn63 it is the standard method. Above dn63 the fittings change to electrofusion or butt fusion because the socket fusion process itself stops at dn63.

Will PE fittings survive frost?

PE takes freeze expansion far better than rigid pipe, which is why it is used in ground that freezes. The fitting itself is not the vulnerable part; a line that is drained before the frost is safer than one that relies on the material.