HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water
HDPE Electrofusion Coupling (PE100) for Gas and Water Mains
An HDPE electrofusion coupler joins two lengths of the same-diameter PE pipe. A copper coil cast into the socket wall melts the coupler bore and the pipe surface into a single layer of PE, so the finished joint carries the same pressure rating as the pipe on either side of it.
We mould these couplers in virgin PE100 from DN20 up to DN1400, in SDR11 (PN16) and SDR17 (PN10). The top of that range is what sets it apart: most electrofusion couplers on the market stop at DN630. A DN1400 coupler is what lets a contractor close a joint on a large municipal main where a butt fusion machine will not fit - in a narrow trench, under a road crossing, or on a repair cut between two fixed points.
How an HDPE electrofusion coupler joint is formed
Both faces being melted are the same material. That is the whole point of electrofusion, and it is why the weld does not depend on the operator's judgement the way hot-plate welding does:
- One-piece body. The heating coil is cast into the bore during moulding, not fitted afterwards - there is no gap between coil and polymer to cause localised overheating.
- Barcode-set welding cycle. The machine scans the code on the fitting and loads the correct voltage and time itself. Nothing is dialled in by hand.
- Indicator pins. The weld is done when the pins pop out. No temperature reading to interpret.
- No filler, no external heat. Nothing enters the pressure boundary, and the joint is not weakened by a heat source sitting on the pipe wall.
Technical Specifications
| Product name | HDPE electrofusion coupler / electrofusion coupling |
|---|---|
| Raw material | 100% virgin PE100, no regrind |
| Size range | DN20 – DN1400 |
| Wall series | SDR11, SDR17 |
| Working pressure | PN16 (SDR11), PN10 (SDR17) |
| Standard | ISO 4427 and EN 12201 (water supply); ISO 4437 and EN 1555 (gas) |
| Jointing method | Electrofusion - barcode-controlled weld cycle, any compatible EF welding machine |
| Colour | Black, UV stabilised; gas-grade yellow marking available |
| Application | Drinking water supply, natural gas distribution, municipal engineering, mining, industrial pipelines |
| Certification | ISO 9001:2015, CE, SGS |
| Custom service | Own logo moulded in, custom carton and pallet specification, project scheduling |
| Service life | 50 years and over under rated conditions |
Sizes and current availability
Two sizes are worth checking before you quote a project, because their status is not the same as the rest of the range:
| Size | Status |
|---|---|
| DN20 – DN1400 | Moulded in our own presses. Standard production range. |
| DN1400 | Tooling complete. DN1400 goes into volume production in mid-October 2026 - it can be written into a project schedule now and we are taking enquiries against a firm delivery date. |
| DN32 (1:8) | New mould, already in production. |
Coupler dimensions: Ø D, L1 and L
Where a project has to be dimensioned before it is priced - trench width, valve chamber depth, the gap left between two fixed points on a repair - these are the three figures that matter. Every size is a nominal value with its moulding tolerance.
- Ø D - outside diameter of the coupling, in mm
- L1 - socket insertion depth, the zone melted on each end, in mm
- L - overall length of the coupling body, in mm
SDR is the Standard Dimension Ratio: SDR11 is the PN16 wall series, SDR17 the PN10 series. All dimensions are in millimetres.

Dimensioned section through the coupling: Ø D outside diameter, L1 socket depth at each end, L overall body length.
| Nominal size | Ø D (mm) outside diameter of coupling |
L1 (mm) socket depth, each end |
L (mm) overall length |
|---|---|---|---|
| Dn20 | 33±2 | 35±2 | 72±3 |
| Dn25 | 39±2 | 42±2 | 85±3 |
| Dn32 | 44±2 | 42±2 | 86±3 |
| Dn40 | 55±2 | 47±2 | 98±3 |
| Dn50 | 64±2 | 50±2 | 100±3 |
| Dn63 | 80±2 | 52±2 | 105±3 |
| Dn75 | 95±2 | 57±2 | 115±3 |
| Dn90 | 111±2 | 62±2 | 125±3 |
| Dn110 | 133±2 | 70±2 | 140±3 |
| Dn125 | 154±2 | 70±2 | 142±3 |
| Dn140 | 173±2 | 77±2 | 155±3 |
| Dn160 | 193±2 | 82±2 | 165±3 |
| Dn180 | 218±2 | 92±2 | 185±3 |
| Dn200 | 240±2 | 95±2 | 190±3 |
| Dn225 | 270±2 | 105±2 | 210±3 |
| Dn250 | 298±2 | 107±2 | 215±3 |
| Dn280 | 337±2 | 107±2 | 215±3 |
| Dn315 | 376±2 | 118±2 | 238±3 |
| Dn355 | 427±3 | 135±3 | 275±4 |
| Dn400 | 479±3 | 142±3 | 285±4 |
| Dn450 | 538±3 | 162±3 | 326±4 |
| Dn500 | 598±4 | 189±3 | 378±4 |
| Dn560 | 670±4 | 194±3 | 388±4 |
| Dn630 | 752±4 | 208±3 | 418±4 |
| Dn710 | 848±4 | 222±3 | 445±5 |
| Dn800 | 954±5 | 235±3 | 470±5 |
| Dn900 | 1080±8 | 260±3 | 520±5 |
| Dn1000 | 1200±8 | 290±3 | 580±5 |
| Dn1200 | 1440±8 | 335±3 | 670±5 |
| Nominal size | Ø D (mm) outside diameter of coupling |
L1 (mm) socket depth, each end |
L (mm) overall length |
|---|---|---|---|
| Dn110 | 129±2 | 52±2 | 107±3 |
| Dn160 | 185±2 | 68±2 | 138±3 |
| Dn200 | 229±2 | 80±3 | 162±4 |
| Dn225 | 258±2 | 88±3 | 178±4 |
| Dn250 | 286±2 | 95±3 | 192±4 |
| Dn315 | 360±3 | 116±3 | 235±4 |
| Dn355 | 407±3 | 135±3 | 270±4 |
| Dn400 | 452±3 | 140±3 | 280±4 |
| Dn450 | 510±3 | 160±3 | 320±4 |
| Dn500 | 565±4 | 180±3 | 360±4 |
| Dn560 | 647±4 | 190±3 | 380±4 |
| Dn630 | 712±4 | 195±3 | 390±4 |
| Dn710 | 805±4 | 217±3 | 435±5 |
| Dn800 | 905±5 | 230±3 | 460±5 |
| Dn900 | 1020±8 | 260±3 | 515±8 |
| Dn1000 | 1133±8 | 290±3 | 580±8 |
| Dn1200 | 1360±8 | 335±3 | 670±8 |
DN1400 can go into volume production straight away. Tooling is complete and the size goes into production in mid-October 2026 - it is a production size now, not a development item, so DN1400 can be written straight into a project schedule. The two tables above stop at dn1200: send us the DN1400 enquiry and we will confirm the figures rather than have you scale them up from dn1200.
The SDR17 tables start at dn110. For a smaller SDR17 size, send the pipe specification and we will confirm what is mouldable.
Features
- Virgin PE100 only. No recycled material, which is what keeps the wall thickness consistent across a 70-fold size span.
- Coil cast into the bore. Heating is uniform along the full socket length, which is where voids and cold welds usually start.
- Dimensional tolerance held to pipe standard. Couplers seat without shimming or extra force on site.
- Pressure tested before dispatch. Every batch, not samples.
- 42 injection presses in-house. Capacity is ours, so lead time does not depend on a subcontractor's queue.
Applications
Two duties account for most of the volume we ship: natural gas distribution and drinking water supply. They are produced to different standards, so tell us which one the line carries when you enquire - gas side to ISO 4437 / EN 1555-3, water side to ISO 4427 / EN 12201-3.
Natural gas and other gases
- Natural gas distribution mains and city gas networks, medium and low pressure
- Gas service connections, risers and meter set pipework
- Valve, regulator and district station tie-ins
- Repair cuts and tie-ins on buried gas mains
- Biogas and landfill gas collection pipework
Water and industrial
- Municipal drinking water supply and distribution networks
- Industrial process water, wastewater and chemical fluid transfer
- Farmland irrigation and landscape water systems
- Mining slurry and low-pressure industrial piping
- Pipeline repair, rehabilitation and tie-in work
Installation
- Cut the pipe square with a rotary cutter, not a saw. A saw leaves swarf in the bore.
- Scrape the full insertion depth to remove the oxidised skin - this is the step that decides weld strength, and the one most often rushed.
- Wipe the scraped pipe end and the coupler bore with a clean dry cloth. No solvent, no oil.
- Mark the insertion depth on the pipe, and push both ends in to the mark. Do not twist.
- Clamp the assembly, connect the welder electrodes, and let the machine read the barcode.
- Do not release the clamps or stress the joint until the cooling time on the fitting label has fully elapsed.
FAQ
What is an HDPE electrofusion coupler used for?
It joins two lengths of the same-diameter HDPE pipe. The fused joint carries the same pressure rating as the pipe either side of it, which is why it is used on buried water and gas mains where a mechanical joint would be the weak point.
What sizes can you supply?
DN20 to DN1400, across SDR11 (PN16) and SDR17 (PN10). Ø D, L1 and L for every size up to dn1200 are in the dimension tables above. DN1400 tooling is complete and the size goes into volume production in mid-October 2026, so it can be scheduled now. Non-standard sizes can be quoted.
Do you supply gas-grade couplers?
Yes. The SDR11 range is produced to ISO 4437 and EN 1555 for gas distribution. The SDR17 range follows ISO 4427 and EN 12201 for water supply.
What is the largest coupler you make?
DN1400. Most electrofusion couplers on the market stop at DN630, so DN1400 is aimed at large municipal mains and repair cuts where a butt fusion machine cannot be positioned.
Can you supply OEM and project quantities?
Yes - your logo moulded into the body, your carton and pallet specification, and pricing quoted against your project schedule rather than a stock list.
Related fittings in the same system: electrofusion transition coupler for size changes, electrofusion elbows, electrofusion tees, end caps and the full electrofusion fittings range. For welding equipment see HDPE electrofusion welding machines, and for the DN1400 size specifically, DN1400 PE electrofusion coupler.
Certifications and compliance documents
Every document below is issued to Zhejiang Qingfa Pipe Technology Co., Ltd. and can be sent as a PDF with your quotation, together with batch test reports for the sizes on the order. We list the scope and the expiry date rather than only a logo, because most buyers have to file them.
| Document | Issued by | Covers |
|---|---|---|
| ISO 9001:2015 quality management system (GB/T 19001-2016) |
Beijing Zhongjing Quality Certification Co., Ltd. (ZJQC) | Production and service of polyethylene (PE) pipe fittings and PE ball valves. Audited annually under CNAS oversight. |
| ISO 14001:2015 environmental management system (GB/T 24001-2016) |
China Economic Certification (Beijing) | Environmental management for PE pipe fittings and PE ball valve production and service. |
| ISO 45001:2018 occupational health and safety (GB/T 45001-2020) |
Beijing Zhongjing Kehuan Quality Certification Co., Ltd. | Occupational health and safety management for PE pipe fittings and PE ball valve production. |
| ECM type approval attestation ECM Mark: Type Approved · No. 1N241120.ZQPSW72 |
Ente Certificazione Macchine S.r.l., Italy | EN 12201-3:2024 and EN 1555-3:2021, related to CE Directive R 305/2011. Covers DN20 to DN1200. Issued 20 November 2024, valid to 19 November 2029. |
| CNAS laboratory accreditation ISO/IEC 17025:2017 |
China National Accreditation Service for Conformity Assessment | Qingfa's in-house testing centre, under accreditation criteria CNAS-CL01. Covers the tests listed in the accreditation annex. |
| WRAS material approval BS 6920-1:2014 |
WRAS, United Kingdom | PE100 black HDPE pipe fittings for contact with drinking water up to 65 °C. Material approval. |
| Five-star after-sales service certificate GB/T 27922-2011 |
Commodity After-sales Service Evaluation System assessment | After-sales service system for HDPE pipe fittings products. |
Where the certificates stop. The ECM attestation covers DN20 to DN1200. Above that, a coupler is supplied with a mill certificate and a batch test report rather than a CE mark. If your drawing specifies a size above DN1200 for an EU or UK project, tell us at enquiry and we will confirm which document we can issue for that size before you order.
Gas duty and water duty are specified separately
A coupler quoted for a natural gas distribution main and one quoted for a drinking water main are working to different standards. Mixing them up is the most common reason an electrofusion fitting is rejected at goods-in, so the standard is written on our quotation rather than left to the drawing. Both duties come off the same coupler range.
| Duty | Standards the couplers are produced to | Wall series |
|---|---|---|
| Drinking water supply | ISO 4427-3 and EN 12201-3:2024, with material approval to BS 6920-1:2014 for UK potable work | SDR11 (PN16) SDR17 (PN10) |
| Natural gas distribution | ISO 4437 and EN 1555-3:2021, plus GB 15558.2 for the Chinese gas market. ECM type approval to EN 1555-3:2021 covers DN20 to DN1200. | SDR11 SDR17 |
Gas is the duty where electrofusion earns its place. A buried gas main runs under roads, through built-up areas and across other services - which is exactly where a butt fusion machine cannot be set up, and where a mechanical joint would be the weak point in the line. The same logic now applies to biogas and landfill gas collection pipework, which is specified in PE far more often than it was ten years ago.
Typical gas-side applications for this coupler: natural gas distribution mains and city gas networks at medium and low pressure, gas service connections and risers, valve and regulator station tie-ins, and repair cuts on live mains where the line cannot be taken out of service for long.
If your specification is written to a gas standard, send the standard number and the MOP with your enquiry and we will match the wall series to it rather than assuming a water duty.
Click any certificate to open the full-size scan. If you need the certificate pack before a tender deadline, say so in the enquiry and we will send the PDFs the same day rather than after the order is placed.
Accreditation documents are also listed on our certificate page. For how the plant is audited day to day, see workshop photos.
Where these couplers are made
Qingfa has been moulding PE fittings in Hemudu, Yuyao since 1994. The site runs 42 injection moulding machines, close to 50 CNC machining stations, and its own turning and heating-coil wiring workshop for sizes and one-off work that a mould cannot cover.
That matters for a coupler more than for most fittings. The bore tolerance and the position of the heating coil are both set by the mould, so a coupler we quote as DN1400 comes off a press, not a lathe. Where a size is turned rather than moulded, we say so on the quote, because the lead time and the price are different.
Super-large injection moulding machine - the presses that make the large-bore sizes
Central feeding system serving the moulding hall
Injection moulding workshop
Turning and heating-coil wiring workshop
Testing before the batch leaves
Fittings are pressure tested and dimensionally checked against the size on the order before packing. The testing centre holds CNAS accreditation to ISO/IEC 17025:2017, so the reports we issue sit inside a scope that your own or a third-party laboratory can verify rather than taking on trust.
More site photographs: factory view, workshop, and a plant video walk-through. Selected project references are published here.
Water pipeline project, Xinjiang, China
Gas distribution project, Russia
Municipal project, Guangdong, China
Pipeline project, Indonesia
Packing, marking and shipping
Fittings are packed to the specification on your order rather than to a default: your logo moulded into the body, your carton and pallet layout, your labelling. Mixed container loads are normal for a first order - the MOQ applies to the order, not to each line item.
The plant sits at Hemudu, Yuyao, in the Ningbo port hinterland, and most of our export volume leaves through Ningbo. Commercial documents - invoice, packing list, certificate of origin, batch test reports - are released with the shipping papers instead of being held back for a separate request, which is usually what slows a customs clearance down.
Finished fittings packed and staged in the warehouse
Packing and loading photographs. If your buyer needs to see how a specific size is packed - crate, pallet, stack height, edge protection, container loading - ask for photographs at enquiry and we will send them for the size on your order before it ships.
Download the product catalogue, or send the sizes and pressure class from your drawing through the enquiry form and we will come back with packing and lead time together.
Zhejiang Qingfa Pipe Technology Co., Ltd.
Xiaojingpu Industry Park, Hemudu Town, Yuyao, Zhejiang, China
Tel / WhatsApp: +86 15168131515 · Email: julie@zjqingfa.com
Qingfa Industry manufactures HDPE Electrofusion Coupling alongside the full PE100 range of electrofusion, butt fusion and socket fusion fittings. Established in 1999, the company holds CE, ISO 9001 and WRAS approvals. See our production and certificates.
Hot Tags: HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water, HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water dn20-dn1400, HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water SDR11/SDR17, HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water dn20-dn1400 SDR11/SDR17, PE100 hdpe electrofusion coupling | pe100 coupler, gas & water, hdpe electrofusion coupling | pe100 coupler, gas & water supplier, Electric Fusion Coupling, 12 Electrofusion Coupling, Coupler Electrofusion, Central Electrofusion Couplings, Electrofusion Transition Coupler, Electro Fusion Coupling
You Might Also Like
Send Inquiry