Couplers are moulded from PE100 HDPE and fused to PE pressure pipe. The range covered on this page runs dn20 to dn1400 in SDR17. Sizes are quoted as dn, the outside diameter of the pipe in millimetres.

Everything below applies to the Coupler Electrofusion specifically. The neighbouring pages in this section cover selection, dimensions, installation and the application side separately.

Product range

The Coupler Electrofusion family covers couplings, elbows, tees, reducing tees, saddle tees, end caps, reducers, flange adaptors and transition fittings.

Each type is moulded to the outside diameter of the pipe it joins, so a fitting and its pipe share one fusion geometry. For the Coupler Electrofusion that means the socket depth and the fusion zone are set by the dn size and the wall series together, not by the fitting type.

Size range and wall series

Sizes for the Coupler Electrofusion are grouped into bands by the work they do.

Size bandWall seriesTypical use
dn20 - dn63SDR17service and house connections
dn75 - dn160SDR17distribution mains
dn180 - dn400SDR17trunk mains and industrial lines
dn450 - dn630SDR17large bore and project supply
dn710 - dn1400SDR17spigot and fabricated fittings

Wall series held are SDR17. A unit moulded for one series will not close correctly on pipe of the other, which is the single most common cause of a rejected joint on this product.

Material and marking

Couplers are moulded from PE100 HDPE compound with the lot certificate on file. Each unit carries the dn size, the SDR and the material grade on the body; black compound with a co-extruded stripe is the standard supply.

Do not fuse a Coupler Electrofusion whose marking cannot be read. If the marking is missing, the unit cannot be matched to a wall series and the joint cannot be qualified.

Applications

Couplers are used for potable water distribution, gas distribution, industrial process lines, mining dewatering and irrigation. Where the trench is narrow or the pipe cannot be clamped square, this family is chosen over butt fusion because the joint is made from outside the pipe.

For the Coupler Electrofusion the range that matters in every one of those sectors is dn20 to dn1400, and the wall series follows from the design pressure of the line rather than from the sector itself.

Ordering information

Quote the type, the dn size, the SDR of the mating pipe and the destination port. For the Coupler Electrofusion the size band to state is dn20 to dn1400.

Specifications

Sizes are held by group rather than as one ladder: 7 groups, dn20 to dn1400 overall. The table gives the dn range and the size count for each group.

Sub-familySize rangeSizes listed
Electrofusion Straight Couplingdn20–dn140032
Electrofusion 90° Elbowdn25–dn90027
Electrofusion 45° Elbowdn25–dn90026
Electrofusion Equal Teedn25–dn63025
Electrofusion Reducing Teedn25–dn63079
Electrofusion End Capdn40–dn31511
Electrofusion Reducing Couplingdn32–dn45045

A size is only quotable once it is read as a pair: the dn and the wall series. The same dn in two series is two different moulds, so the series has to travel with the size on the enquiry.

The full size-by-size matrix for each of these groups is on the specification library.

Related pages

Other pages in the Coupler Electrofusion section, each covering a different angle of the same product family:

Family data for Coupler Electrofusion: the reducer and coupling size chart gives every straight and reducing combination, by outside diameter, and the electrofusion coupling page lists the sizes, pressure classes and material grades we mould.

  • EF Coupler

    EF Coupler — a compact, easy-to-install electrofusion coupling for joining PE and HDPE pipes quickly and reliably in the field. Features: • Lightweight design simplifies handling in tight spaces •

  • DN1400 PE Electrofusion Coupler – SDR17 PN10, PE100

    Large-diameter DN1400 PE100 electrofusion straight coupler, SDR17 PN10, for HDPE gas and water mains. Built-in copper heating coil, barcode-controlled welding, PE100 virgin resin, ISO 4427 compliant.

  • Electrofusion Transition Coupler

    Transition Electrofusion Coupler — an adaptable electrofusion coupling engineered to connect PE pipes across different sizes and pressure classes with a secure fusion joint. Features: •

  • Electro Fusion Coupler

    Electro Fusion Coupler — a high-performance electrofusion coupling offering a gas-tight, durable fusion connection for polyethylene piping systems. Features: • Optimized heating zones ensure

  • Coupler Electrofusion

    Electrofusion Coupler — a purpose-built electrofusion coupling engineered for dependable, long-term joints in PE and HDPE pipe networks. Features: • Embedded heating wires deliver fast, uniform

  • Electrofusion Coupling

    Electrofusion Coupling — a versatile straight fusion joint that delivers a strong, leak-free connection for PE and HDPE pipe systems in standard SDR11 and SDR17 pressure ratings. Features: • Evenly

  • Hdpe Fitting Electrofusion Coupling

    Products Description hdpe fitting electrofusion coupling is the core connection pipe fitting of the PE pipeline system, used for the straight-line connection of equal-diameter HDPE pipes. The product

  • HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water

    PE100 electrofusion coupler for natural gas distribution and drinking water mains, DN20-DN1400 in SDR11 / SDR17. To ISO 4437 / EN 1555-3 and ISO 4427 / EN 12201.

  • Central Electrofusion Couplings

    Central Electrofusion Couplings — a full-range series of straight electrofusion fittings delivering symmetrical, balanced joints across PE pipe diameters. Features: • Centered heating coils promote

Luz Colon star star star star star
Your machinery and equipment is unmatched in this field and we hope that this transaction will maximize the benefits for both parties.
Louis Dewees star star star star star
I really like these products, the seller is really nice and very patient to help me!
Donald Weis star star star star star
We have bought many times. We like your products. They are not only solid in quality, but also cheap. They are very effective.
Brian Hollars star star star star star
The employees who serve on the front line are the most important spokespeople for the image of the whole company and show the quality of service.
Randy Turner star star star star star
Your company is a highly competitive enterprise, and when we received the goods, our friends were full of praise and said that they would also come to buy your products.
Luz Schoenberger star star star star star
I am very satisfied with your customized service, thank you.
Electrofusion Fittings - Integrity Fusion...

WebSDR 17 Electrofusion Coupler | IPS Series Water - 125 PSI (ASTM) / 145 PSI (ISO) @ 73° F Sustainable Maximum Operating Pressure Suitable for use on IPS SDR 17 to SDR 26...

PN16 SDR11 PE100 HDPE Electrofusion Fittings , HDPE …...

WebElectrofusion coupler or coupling is the most commonly used HDPE fittings whatever for water supply, Gas or Fire fighting etc. PN20&PN16&PN10 is available. Main reasons to...

HDPE Electrofusion Coupler - Ningbo Sunplast Pipe Co., Ltd...

WebHDPE electrofusion coupler, also called HDPE electrofusion coupling, is the most common & regular fittings that are used to join two lengths of poly pipe in a straight line, and it can...

Electrofusion - Integrity Fusion...

WebElectrofusion Coupler Improved technology eliminating the need for pre-heating procedures Utilizes higher Amperage (105A) to create more heat, allowing the pipe to expand to help reduce any gaps...

Electrofusion Couplers — Strongbridge International LLC | HDPE …...

WebElectrofusion Couplers. Size Range . SDR 7. 2" to 22" IPS (fusible to SDR 6-9) Water: 360 PSI at 73° F . Sustainable maximum operating pressure . SDR 11 . ¾” to 42" IPS (fusible...

HDPE Electrofusion Coupler - Elbor Makine - Elborweltech...

WebA coupler means “a thing that connects two things, especially mechanical components or systems.” In the industry, the coupler is an important piece to connect pipes. It is used to...

Coupler Electrofusion covers dn20 to dn1400 in SDR17 on this page. The dimension that decides fit is the fusion zone, and it is set by the dn size and the wall series together, so a unit made for one series will not close correctly on pipe of the other. For a quotation, state the fitting type, the dn size, the pipe SDR and the destination port. Related pages on this site: HDPE Butt Fusion Coupling, Frialen Electrofusion Couplings and Gf Electrofusion Coupler.

Send Inquiry