Selecting the HDPE Electrofusion Coupling comes down to matching three variables: the dn size of the pipe, the SDR of that pipe, and the joint type. Get those right and the fusion geometry follows on its own.
This page is the decision sequence; the numbers themselves are on the dimensions page.
Step 1: confirm the pipe size and SDR
Measure the pipe outside diameter and read the SDR from the pipe marking. The HDPE Electrofusion Couplings are supplied dn110 to dn1400 in SDR17.
| Size band | Wall series | Typical use |
|---|---|---|
| dn110 - dn250 | SDR17 and SDR11 | trunk mains and industrial lines |
| dn280 - dn560 | SDR17 and SDR11 | large bore and project supply |
| dn630 - dn1400 | SDR17 and SDR11 | large bore and project supply |
If the pipe marking is unreadable, measure the wall at three points round the circumference and divide the outside diameter by the mean wall. For the HDPE Electrofusion Coupling that gives the SDR closely enough to pick the right unit.
Step 2: match the unit to the pipe series
A socket moulded for SDR11 will not close on SDR17 pipe. The socket depth and the fusion zone are set by the wall series, not by the dn size, so the pair has to be matched for the HDPE Electrofusion Coupling.
Where a line mixes series, order the HDPE Electrofusion Couplings against the pipe actually being laid at each joint, not against the nominal size of the run.
Step 3: check the pressure class
Pressure class follows from the wall series and the material grade. Confirm the design pressure of the line before the HDPE Electrofusion Couplings are ordered, because a change of series after moulding is a new tool, not a re-label. The series on offer are SDR17 across dn110 to dn1400.
Common selection mistakes
The mistakes below account for most re-quotes on the HDPE Electrofusion Coupling across the dn110 to dn1400 range:
- Quoting a dn size without the SDR.
- Mixing unit and pipe from different wall series.
- Assuming one unit suits both electrofusion and butt fusion joints.
- Ordering to an imperial size when the line is metric.
- Choosing on price alone for a line whose design pressure is fixed.
Specifications
This is the working specification for the Electrofusion Coupling: 30 sizes from dn20 to dn400, each listed against the wall series it is actually tooled in. Read the row for the size on the drawing before the enquiry goes out.
| dn | SDR 9 available | SDR 11 available | SDR 17 available |
|---|---|---|---|
| dn20 | ✓ | ✓ | - |
| dn25 | ✓ | ✓ | - |
| dn32 | ✓ | ✓ | - |
| dn40 | ✓ | ✓ | - |
| dn50 | ✓ | ✓ | - |
| dn63 | ✓ | ✓ | - |
| dn75 | ✓ | ✓ | - |
| dn90 | ✓ | ✓ | - |
| dn110 | ✓ | ✓ | ✓ |
| dn125 | ✓ | ✓ | - |
| dn140 | ✓ | ✓ | - |
| dn160 | ✓ | ✓ | ✓ |
| dn180 | ✓ | ✓ | - |
| dn200 | ✓ | ✓ | ✓ |
| dn225 | ✓ | ✓ | ✓ |
| dn250 | ✓ | ✓ | ✓ |
| dn280 | ✓ | ✓ | ✓ |
| dn315 | ✓ | ✓ | ✓ |
| dn355 | - | ✓ | ✓ |
| dn400 | - | ✓ | ✓ |
| dn450 | - | ✓ | ✓ |
| dn500 | - | ✓ | ✓ |
| dn560 | - | ✓ | ✓ |
| dn630 | - | ✓ | ✓ |
| dn710 | - | ✓ | ✓ |
| dn800 | - | ✓ | ✓ |
| dn900 | - | ✓ | ✓ |
| dn1000 | - | ✓ | ✓ |
| dn1200 | - | ✓ | ✓ |
| dn1400 | - | ✓ | ✓ |
Wall thickness follows from the series, not from the size: wall = dn / SDR. That is why a body tooled in SDR 11 and one tooled in SDR 17 are separate moulds at the same dn. SDR 9, 11 and SDR 17 here; the PN figures quoted are for PE100 in water at 20 °C and need derating for temperature and for gas duty.
Pressure class by wall series
| SDR | PN at 20 °C, PE100 water | Typical duty |
|---|---|---|
| SDR 9 | PN 20 | the highest pressure class in the range |
| SDR 11 | PN 16 | standard pressure pipe, gas and water |
| SDR 17 | PN 10 | large bore mains and lower pressure lines |
Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.
Related pages
Other pages in the HDPE Electrofusion Coupling section, each covering a different angle of the same product family:
Family data for HDPE Electrofusion Coupling: the reducer and coupling size chart gives every straight and reducing combination, by outside diameter, and the electrofusion coupling page lists the sizes, pressure classes and material grades we mould.
-
HDPE Electrofusion Coupling | PE100 Coupler, Gas & Water
PE100 electrofusion coupler for natural gas distribution and drinking water mains, DN20-DN1400 in SDR11 / SDR17. To ISO 4437 / EN 1555-3 and ISO 4427 / EN 12201.
-
DN1400 PE Electrofusion Coupler – SDR17 PN10, PE100
Large-diameter DN1400 PE100 electrofusion straight coupler, SDR17 PN10, for HDPE gas and water mains. Built-in copper heating coil, barcode-controlled welding, PE100 virgin resin, ISO 4427 compliant.
-
Electrofusion Transition Coupler
Transition Electrofusion Coupler — an adaptable electrofusion coupling engineered to connect PE pipes across different sizes and pressure classes with a secure fusion joint. Features: •
-
Electro Fusion Coupler
Electro Fusion Coupler — a high-performance electrofusion coupling offering a gas-tight, durable fusion connection for polyethylene piping systems. Features: • Optimized heating zones ensure
-
Coupler Electrofusion
Electrofusion Coupler — a purpose-built electrofusion coupling engineered for dependable, long-term joints in PE and HDPE pipe networks. Features: • Embedded heating wires deliver fast, uniform
-
Electrofusion Coupling
Electrofusion Coupling — a versatile straight fusion joint that delivers a strong, leak-free connection for PE and HDPE pipe systems in standard SDR11 and SDR17 pressure ratings. Features: • Evenly
-
Hdpe Fitting Electrofusion Coupling
Products Description hdpe fitting electrofusion coupling is the core connection pipe fitting of the PE pipeline system, used for the straight-line connection of equal-diameter HDPE pipes. The product
-
EF Coupler
EF Coupler — a compact, easy-to-install electrofusion coupling for joining PE and HDPE pipes quickly and reliably in the field. Features: • Lightweight design simplifies handling in tight spaces •
-
Central Electrofusion Couplings
Central Electrofusion Couplings — a full-range series of straight electrofusion fittings delivering symmetrical, balanced joints across PE pipe diameters. Features: • Centered heating coils promote
The basis for using pipe restraint and/or support when joining two pieces of PE pipe with an electrofusion coupling is to: ·Minimize potential short-stab, mis-stab or binding situations...
Aug 20, 2021 · HDPE Electrofusion coupler fittings are made of PE100 material and have a properly moulded energizing coil of wire, which provides uniform melting for a strong...
ELOFIT is a PEHD - High Density Polyethylene PE100 - system of fittings for electrofusion and butt-fusion, PE-metal transition fittings and special components for the conveyance of fluids...
Electrofusion Coupling 1/2" CTS 230psi. SKU: 12EIME12C. $8.20. Add To Cart. Electrofusion Coupling 1/2" IPS 230psi. SKU: 12EIME012. $10.96. Add To Cart. Electrofusion Coupling 3/4"...
Electrofusion Reducer Coupling 3" IPS x 2" IPS 230psi. SKU: 12EIRDE0302. $43.96. Add To Cart. Electrofusion Reducer Coupling 4" IPS x 2" IPS 230psi. SKU: 12EIRDE0402. $55.26. Add To...
Product Description EloFit Electrofusion Coupling For Use with SDR17 or Thicker Pipe Gas, Water, Sewer, Geothermal and other Industrial Applications, PE 4710 Black, Bar Code Capable,...