Selecting the Tee Electrofusion comes down to matching three variables: the dn size of the pipe, the SDR of that pipe, and the joint type. Get those right and the fusion geometry follows on its own.
This page is the decision sequence; the numbers themselves are on the dimensions page.
Step 1: confirm the pipe size and SDR
Measure the pipe outside diameter and read the SDR from the pipe marking. The Tees are supplied dn20 to dn630 in SDR11 and SDR17.
| Size band | Wall series | Typical use |
|---|---|---|
| dn20 - dn110 | SDR11 and SDR17 | distribution mains and industrial lines |
| dn125 - dn250 | SDR11 and SDR17 | trunk mains and industrial lines |
| dn280 - dn630 | SDR11 and SDR17 | large bore and project supply |
If the pipe marking is unreadable, measure the wall at three points round the circumference and divide the outside diameter by the mean wall. For the Tee Electrofusion that gives the SDR closely enough to pick the right unit.
Step 2: match the unit to the pipe series
A socket moulded for SDR11 will not close on SDR17 pipe. The socket depth and the fusion zone are set by the wall series, not by the dn size, so the pair has to be matched for the Tee Electrofusion.
Where a line mixes series, order the Tees against the pipe actually being laid at each joint, not against the nominal size of the run.
Step 3: check the pressure class
Pressure class follows from the wall series and the material grade. Confirm the design pressure of the line before the Tees are ordered, because a change of series after moulding is a new tool, not a re-label. The series on offer are SDR11 and SDR17 across dn20 to dn630.
Common selection mistakes
The mistakes below account for most re-quotes on the Tee Electrofusion across the dn20 to dn630 range:
- Quoting a dn size without the SDR.
- Mixing unit and pipe from different wall series.
- Assuming one unit suits both electrofusion and butt fusion joints.
- Ordering to an imperial size when the line is metric.
- Choosing on price alone for a line whose design pressure is fixed.
Specifications
The table below lists every size held for the Electrofusion Tee and the wall series available at each size. The ladder runs dn25–dn630 - 22 sizes - in SDR 9, 11 and SDR 17.
| dn | SDR 9 available | SDR 11 available | SDR 17 available |
|---|---|---|---|
| dn25 | ✓ | ✓ | - |
| dn32 | ✓ | ✓ | - |
| dn40 | ✓ | ✓ | - |
| dn50 | ✓ | ✓ | - |
| dn63 | ✓ | ✓ | - |
| dn75 | ✓ | ✓ | - |
| dn90 | ✓ | ✓ | - |
| dn110 | ✓ | ✓ | ✓ |
| dn125 | ✓ | ✓ | - |
| dn140 | - | ✓ | - |
| dn160 | ✓ | ✓ | ✓ |
| dn180 | - | ✓ | - |
| dn200 | ✓ | ✓ | ✓ |
| dn225 | - | ✓ | ✓ |
| dn250 | ✓ | ✓ | ✓ |
| dn280 | - | ✓ | - |
| dn315 | ✓ | ✓ | ✓ |
| dn355 | - | ✓ | ✓ |
| dn400 | - | ✓ | - |
| dn450 | - | ✓ | ✓ |
| dn500 | - | ✓ | ✓ |
| dn630 | - | ✓ | ✓ |
Wall thickness follows from the series, not from the size: wall = dn / SDR. That is why a body tooled in SDR 11 and one tooled in SDR 17 are separate moulds at the same dn. SDR 9, 11 and SDR 17 here; the PN figures quoted are for PE100 in water at 20 °C and need derating for temperature and for gas duty.
Pressure class by wall series
| Wall series | Pressure class (PE100, water, 20 °C) | Where it is used |
|---|---|---|
| SDR 9 | PN 20 | the highest pressure class in the range |
| SDR 11 | PN 16 | standard pressure pipe, gas and water |
| SDR 17 | PN 10 | large bore mains and lower pressure lines |
Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.
Related pages
Other pages in the Tee Electrofusion section, each covering a different angle of the same product family:
-
HDPE Electrofusion Tee
Electrofusion equal and reducing tee for HDPE gas and water pipelines, DN20-1000mm.
-
EF Tapping Tee
This EF tapping tee lets a PE100 branch be added to an operative water or gas main while the pipeline continues to flow. It combines a fusion saddle with a moulded outlet into one component, so a
-
Electrofusion Reducing Tee
Electrofusion Reducing Tee is a type of pipe fitting used in plastic pipe systems, suitable for branch connections of pipes of different diameters. It adopts the brand-new high-density polyethylene
-
Electrofusion Saddle Tee
Electrofusion Saddle Tee is a type of branch connection pipe fitting used for plastic pipes, suitable for directly leading out branch pipes from the main pipe without cutting the main pipe. It is
Electrofusion tee Electrofusion end cap Electrofusion elbow. Electrofusion fittings. Electrofusion fittings are manufactured using modern, automated lines for plastic processing. It guarantees...
IPEX/Friatec is a leader in electrofusion fitting technology for HDPE pipe systems. With our proven products and expertise, Friatec Fittings are frequently called upon to solve the toughest...
PE Electrofusion Solutions. Friatec products are engineered smarter than traditional fusion systems. Manufactured in the USA, Friatec couplings feature a unique, exposed coil design that...
Made by 100% PE100 material, SUNPLAST HDPE reducing tee electrofusion can can be supplied in a diameter sizing from dn32~dn400mm in SDR11-PN16. SDR 11 electrofusion tee reducer fittings are rated to...
Electrofusion Tees . HDPE Electrofusion Tees are available to meet your needs in compliance with ASTM D2513, F1055, F2897, and where applicable, AWWA C906 product standards....
HDPE Electrofusion Tap Tees Fittings are available to meet your needs in compliance with ASTM D2513, F1055, F2897, and when applicable, AWWA C906 product standards. Electrofusion...