Electrofusion Tapping Saddle

Electrofusion Tapping Saddle

An electrofusion saddle with an integrated cutter and valve, so a service line can be opened onto a pressurised main without a shutdown. Weld the saddle, then tap straight through the sealed valve — the branch is completed live, with no loss of service and nothing left open to the trench.
Send Inquiry

Electrofusion Tapping Saddle

 

 

Tapping a Live Main With an Integrated Cutter

A tapping saddle turns a probable shutdown into a one-hour branch. The cutter and valve live in the fitting, so after the saddle is fused the outlet is drilled through the closed valve and the tap is finished under full main pressure.

Nothing Left Open to the Trench

The sealed valve traps the flow during and after the cut. That containment is the difference between a tidy live branch and a flooded excavation.

Key features

Integrated cutter and isolating valve.

One live tap without section shutdown.

Sealed throughout, nothing open to the trench.

Applications

Live service connections on pressurised mains.

Where shutting the main is impractical.

Installation note

Fuse the saddle, seal around the cutter, open the valve and tap, then close and cap the outlet.

  •  

Tapping Saddle Models and Coverage

The tapping saddle family is moulded in a single body form, and what separates the models in the range is the mains size the body is cut for rather than the way it works. Every body clamps the main, fuses to it in one cycle and takes the branch cut afterwards with the line still in service. The coverage of each group is set out below, alongside the bypass body that is sometimes the better answer on the same main.

Body groupMains rangeOutlets moulded
Tapping saddle (bypass body)dn63 - dn315dn32, dn50, dn63, dn90, dn110
Branch saddle, current toolingdn63 - dn225dn20, dn25, dn32, dn63
Branch saddle, earlier toolingdn63 - dn315dn32, dn63, dn90, dn110

All of the bodies are pressed in the heavy wall series, and the outlet is fixed by the mould. Where a branch falls outside the outlets of the tapping body, the correct fitting is a bypass saddle on the same main or a tapping tee with a separate outlet piece, not a special body. The sequence on site does not change between models: clamp and tension, run the cycle, let the joint cool for the full period, then cut through. The detailed combinations are on the electrofusion tapping saddle page and the specifications page.

Our Electrofusion Tapping Saddle is moulded and tested in our own factory. Qingfa Industry has produced PE100 fittings for 25 years and today runs over 3,000 product varieties. Meet the manufacturer behind these fittings.

Hot Tags: Electrofusion Tapping Saddle, Electrofusion Tapping Saddle dn63-dn315, PE100 electrofusion tapping saddle, electrofusion tapping saddle supplier, IPS ElectroFusion Branch Saddle HDPE, electrofusion saddle, Electrofusion Tapping Saddle Tee, Electrofusion Branch Saddle, EF Tapping Saddle, HDPE Fusion Saddle

Send Inquiry