Every number on this page is either taken from the standard table or calculated from the two definitions that generate it: the wall is the outside diameter divided by the SDR, and the pressure class comes from the wall. Wall thickness, bore, unit weight and the mm-to-inch conversion sit side by side for dn20 to dn1600, in SDR 11, 17, 21 and 26 – the four series that cover almost every water, gas and irrigation line we quote fittings for.

10SDR series covered
dn20–dn1600diameter range
PN 4–PN 32pressure classes

What SDR means, and what it does not

SDR stands for standard dimension ratio: the outside diameter divided by the wall thickness. It is a ratio, not a measurement, and that single fact explains almost everything else on this page.

SDR = OD ÷ wall  →  wall e = dn ÷ SDR
dn110 SDR 11: 110 ÷ 11 = 10.0 mm  ·  dn110 SDR 17: 110 ÷ 17 = 6.47, nominal 6.6 mm

Because the ratio is fixed, the same SDR gives the same pressure class at every diameter. A dn315 SDR 11 pipe and a dn110 SDR 11 pipe are both PN 16, even though one wall is nearly three times the other. That is why a line is specified by SDR and not by wall thickness: one figure then covers the whole scheme, from the service connection to the trunk main.

Three things get confused with SDR, and they are not the same:

  • PN is the pressure class. It is derived from the SDR, not the other way round.
  • SN is ring stiffness, a different property, and it falls much faster than the wall as the SDR rises. An SDR 17 pipe is not just slightly more flexible than SDR 11 – the stiffness goes with the cube of the wall.
  • Wall in mm is the number you measure, not the number you specify. Two pipes of the same dn and the same SDR may print a wall figure that differs by 0.1 mm depending on which edition of the table the maker worked from.

What SDR does not change is the outside diameter. dn is fixed; the SDR only moves the bore. That is why fittings are sized on dn and rated on SDR, and why a fitting ordered for the wrong series will still slide onto the pipe and still be wrong.

SDR to pressure rating

The pressure class follows from the wall through the thin-wall (Barlow) relationship, with the material's long-term strength divided by a design coefficient:

PN = 2 σ ÷ (SDR − 1)
PE100, water, C = 1.25 → σ = 8.0 MPa → PN = 16 ÷ (SDR − 1)
PE100, gas, C = 2.0 → σ = 5.0 MPa → PN = 10 ÷ (SDR − 1)

Two consequences catch people out. The first is that gas and water are not the same pipe: the same SDR 11 body is PN 16 in water and PN 10 in gas, because the design coefficient doubles. The second is that PN assumes 20 °C and a 50-year life. Above 20 °C the class derates, and by 40 °C an SDR 11 line is no longer a PN 16 line – if the line runs warm, say so and we quote against the derated figure.

SDR to pressure class, PE100 at 20 °C water. The gas column is the same formula with the design coefficient raised from 1.25 to 2.0
SDRWall as % of ODPN, waterpsiPN, gas (bar)Where it is normally used
SDR 412.4%PN 4582.5Large outfalls, low-head gravity
SDR 333.0%PN 5733.1Very low pressure, gravity only
SDR 263.8%PN 6874.0Gravity sewers, stormwater
SDR 214.8%PN 81165.0Irrigation, low-pressure distribution
SDR 175.9%PN 101456.3Water distribution 4–8 bar; gas
SDR 13.67.4%PN 12.51817.9Water to 12.5 bar, process lines
SDR 119.1%PN 1623210.0Pressure mains, 10 bar gas, slurry
SDR 911.1%PN 2029012.5High pressure, penstock, industrial
SDR 7.413.5%PN 2536315.6High-pressure industrial, temporary
SDR 616.7%PN 3246420.0Highest pressure, specialist plant

PN is the nominal class you order; the formula returns 16.0 bar for SDR 11 and 6.4 bar for SDR 26, which is sold as PN 6. Both are right – the class is rounded to the standard step, the calculation is not.

Read the table downwards and the trade-off is obvious: every step down in SDR buys pressure and costs bore. SDR 11 to SDR 17 is six bar of pressure class for about 8% more bore at the same outside diameter.

Wall thickness chart, dn20 to dn1600

The figures below are nominal wall, e = dn ÷ SDR, taken up to the next 0.1 mm – pipe is never rounded down, because a thin wall is a pressure problem and a thick one is only a cost problem. Where a published standard table differs it is by 0.1 mm, from rounding to a different step, and it does not change the SDR you order.

Nominal wall thickness in mm, PE100 – e = dn ÷ SDR
dn / OD (mm)SDR 26SDR 21SDR 17SDR 11
200.81.01.21.9
251.01.21.52.3
321.31.61.93.0
401.62.02.43.7
502.02.43.04.6
632.53.03.85.8
752.93.64.56.9
903.54.35.38.2
1104.35.36.610.0
1254.96.07.411.4
1405.46.78.312.8
1606.27.79.514.6
1807.08.610.616.4
2007.79.611.918.2
2258.710.813.320.5
2509.711.914.822.7
28010.813.416.525.5
31512.215.018.728.6
35513.717.020.932.3
40015.419.123.736.4
45017.421.526.541.0
50019.323.929.645.5
56021.626.733.051.0
63024.330.137.457.3
71027.433.941.864.6
80030.838.147.172.8
90034.742.953.081.9
100038.547.758.991.0
120046.257.270.6109.1
140053.966.782.4127.3
160061.676.294.2145.5

Two things worth checking before you use this as a buying table. First, the wall is nominal, and the manufacturing tolerance in EN 12201-2 and ISO 4427-2 is a plus tolerance on that nominal figure – so a pipe measured slightly under nominal on site is normal, and a pipe well under it is not. Second, the chart is arithmetic – e = dn ÷ SDR holds at every diameter, including combinations nobody fuses, such as dn20 at SDR 26 with a 0.8 mm wall. Where the wall gets that thin the joint, not the pressure, is the problem, and the practical range for each series starts higher up.

If what you have is an inch size rather than a dn, the conversion is further down the page – the short version is that the inch figure is a trade name and the outside diameter is the metric one. A 12 inch HDPE pipe is dn315: 28.6 mm wall at SDR 11, 18.7 mm at SDR 17, 15.0 mm at SDR 21.

SDR 21: the low-pressure workhorse

SDR 21 is PN 8 – 116 psi – and it exists for the jobs where the pump head is modest and the pipe run is long: irrigation mains, gravity-fed distribution, low-pressure rural networks. Against SDR 17 it gives up two bar of class and gains only 2.7% of bore at dn315, so nobody chooses it for the flow. The case for it is cost: the wall is 20% thinner, and PE pipe is priced by mass. Against SDR 11 the bore gain is 10.6%, which is where it becomes a hydraulic decision rather than a budget one.

The complication is on the fitting side. A dn110 SDR 21 pipe has a 5.3 mm wall, and a fitting moulded for SDR 17 expects 6.6 mm at the same diameter. The socket still fits – both are dn110 on the outside – but the fusion parameters and the body wall were designed around a thicker pipe. Our standard moulds are dimensioned for SDR 9, 11 and 17, which is the series column you will see on every fitting page; for an SDR 21 line we confirm the body size by size before quoting rather than assume the SDR 17 item will do.

SDR 26: gravity, not pressure

SDR 26 is PN 6, the thinnest wall in common use, and it is almost never chosen for its pressure rating. It is chosen for sewers, stormwater and outfalls, where the line runs full by gravity and the governing requirement is bore per euro of pipe rather than bar. At dn315 the bore is 290.6 mm against 257.8 mm in SDR 11 – 12.7% more diameter and 27% more cross-section for the same trench.

What it gives up is stiffness. Ring stiffness scales with the cube of the wall, so the drop from 28.6 mm to 12.2 mm at dn315 is not a 56% loss of stiffness but closer to 92%. That is fine in a properly bedded sewer and not fine under a road with shallow cover – which is the reason a SDR 26 line under traffic is usually specified with a granular surround or swapped to SDR 21.

Internal diameter: the number that sets flow

Outside diameter is fixed by dn, so every millimetre of wall comes straight out of the bore, and flow capacity goes with the square of the bore. This is where the SDR decision actually shows up in engineering numbers rather than in a pressure class:

Internal diameter in mm – ID = dn − 2e. This is the figure that sets flow, not the outside diameter
dn (mm)SDR 26SDR 21SDR 17SDR 11
2018.418.017.616.2
2523.022.622.020.4
3229.428.828.226.0
4036.836.035.232.6
5046.045.244.040.8
6358.057.055.451.4
7569.267.866.061.2
9083.081.479.473.6
110101.499.496.890.0
125115.2113.0110.2102.2
140129.2126.6123.4114.4
160147.6144.6141.0130.8
180166.0162.8158.8147.2
200184.6180.8176.2163.6
225207.6203.4198.4184.0
250230.6226.2220.4204.6
280258.4253.2247.0229.0
315290.6285.0277.6257.8
355327.6321.0313.2290.4
400369.2361.8352.6327.2
450415.2407.0397.0368.0
500461.4452.2440.8409.0
560516.8506.6494.0458.0
630581.4569.8555.2515.4
710655.2642.2626.4580.8
800738.4723.8705.8654.4
900830.6814.2794.0736.2
1000923.0904.6882.2818.0
12001107.61085.61058.8981.8
14001292.21266.61235.21145.4
16001476.81447.61411.61309.0

At dn315, SDR 17 gives a 277.6 mm bore against 257.8 mm in SDR 11. That is 7.7% more diameter and 16% more cross-section – the same pump then moves the same flow at a lower velocity, and the friction loss over a kilometre drops by roughly a quarter. On a line where the pump is the expensive item, SDR 17 pays for itself; on a line where the pressure surge is the risk, it does not.

Unit weight, kg per metre

Weight is a freight and handling figure, and for PE it has a second use: the material is lighter than water at 0.95 g/cm³, so an empty pipe floats. On a submerged or high-water-table outfall the weight per metre is the starting point for the ballast calculation.

Unit weight in kg per metre of pipe, PE100 at 0.95 g/cm³ – W = π (dn − e) e × 0.95 / 1000
dn (mm)SDR 21SDR 17SDR 11
200.060.070.10
250.090.110.16
320.150.170.26
400.230.270.40
500.340.420.62
630.540.670.99
750.770.951.40
901.101.342.00
1101.662.042.98
1252.132.603.87
1402.673.264.86
1603.504.276.34
1804.405.368.01
2005.466.689.88
2256.908.4012.5
2508.4610.415.4
28010.713.019.4
31513.416.524.4
35517.120.831.1
40021.726.639.5
45027.533.550.0
50034.041.661.7
56042.551.977.5
63053.966.197.9
71068.483.4124.4
80086.6105.8158.0
900109.7134.0200.0
1000135.6165.4246.9
1200195.1238.0355.2
1400265.4324.0483.5
1600346.5423.3631.6

The figures are pipe only, calculated from the annulus area. A joint adds the fitting, a flange adds the steel ring, and water in the line adds about 1 kg per metre for every 1000 mm² of bore – which for a dn315 line is 60 kg/m against 16.5 kg/m of pipe. A flooded line weighs nearly four times what the pipe weighs, which is why a buoyancy check is done flooded and not empty.

mm and inches: the conversion, and the trap in it

Half the enquiries we get quote an inch size and half quote a dn, and they do not convert exactly. The inch figure is a nominal trade size; the outside diameter is the metric one in the table below. A 4 inch HDPE pipe is dn110, whose outside diameter is 110 mm – 4.33 inches, not 4.00.

Nominal inch size against the metric series, with the outside diameter in both units
Nominal sizeMetric dnOD (mm)OD (inch)Wall, SDR 17Wall, SDR 11
1/2"2020.00.791.21.9
3/4"2525.00.981.52.3
1"3232.01.261.93.0
1 1/4"4040.01.572.43.7
1 1/2"5050.01.973.04.6
2"6363.02.483.85.8
2 1/2"7575.02.954.56.9
3"9090.03.545.38.2
4"110110.04.336.610.0
5"140140.05.518.312.8
6"160160.06.309.514.6
8"200200.07.8711.918.2
10"250250.09.8414.822.7
12"315315.012.4018.728.6
14"355355.013.9820.932.3
16"400400.015.7523.736.4
18"450450.017.7226.541.0
20"500500.019.6929.645.5
24"630630.024.8037.457.3
28"710710.027.9541.864.6
32"800800.031.5047.172.8
36"900900.035.4353.081.9
40"10001000.039.3758.991.0
48"12001200.047.2470.6109.1
Do not order by the inch figure alone. An IPS 4 inch pipe is 114.3 mm on the outside; a metric dn110 is 110 mm. Both are called 4 inch in different markets and neither will take the other's fittings. If the line already exists, send the measured outside diameter and the wall, and we will match the series from those two numbers.

Why the fitting has to match the SDR

This is a fittings site, so the practical question behind every SDR query is: what do I put on the end of this pipe? Four things change with the series, and three of them are invisible once the joint is made.

What actually changes when the SDR changes
 SDR 11 pipeSDR 17 pipeWhat goes wrong if mismatched
Butt fusion body wall9.1% of OD5.9% of ODThe weld is not full-section on the thinner side; the joint rating follows the thin wall, not the fitting
Heating and cooling timeLongerShorterUsing the SDR 11 chart on SDR 17 pipe overheats it; the bead rolls back and the wall thins at the joint
Electrofusion parameter setOne setAnother setThe coil energy is matched to the melt volume; the wrong set gives a cold or a blown weld
Socket depth and insertion markSet by the seriesSet by the seriesPipe pushed short of the mark leaves an unfused band at the bottom of the socket

Our range is dimensioned for SDR 9, 11 and 17, and each fitting page carries the series in its size table rather than assuming one. If a line mixes series – SDR 17 main with an SDR 11 tie-in, which is common where a new connection meets an old main – the transition is made with a fitting moulded for both, and the rating of the joint is the lower of the two.

Which SDR for which job

ApplicationNormal working pressureSDRWhat to watch
Municipal water distribution4 – 8 barSDR 17Surge on long rising mains
Booster and transmission mains10 – 16 barSDR 11Pump start/stop surge; anchor at bends
Service connections, in-buildingup to 10 barSDR 11Small diameters, tight radii, socket fusion to dn63
Gas distributionup to 4 bar MOPSDR 11 or 17The operator's MOP and test pressure decide it
Irrigation, agriculture2 – 6 barSDR 21UV exposure, valve surge at the end of the line
Gravity sewer, stormwaternilSDR 26Ring stiffness under traffic load and cover depth
Mine slurry, tailings8 – 16 barSDR 11Wear allowance – the wall is the wear life

Where the table gives two series, the deciding factor is usually the network operator's standard rather than the physics. Where it gives one, taking the next series up is a cost decision, not a safety one – the exception is gravity work, where a heavier wall buys stiffness, not pressure.

Frequently asked questions

What does SDR 11 mean?

SDR 11 means the outside diameter is 11 times the wall thickness, so the wall is dn ÷ 11 – 10.0 mm on a dn110 pipe. For PE100 in water service it is the PN 16 class: 232 psi at 20 °C. The same ratio holds at every diameter, which is why one SDR figure can specify a whole network.

Is SDR 11 stronger than SDR 17?

In pressure terms yes: SDR 11 is PN 16 and SDR 17 is PN 10 for PE100 water, because the wall is 9.1% of the outside diameter instead of 5.9%. In stiffness terms the gap is much wider, since ring stiffness follows the cube of the wall. SDR 17 is not a weaker version of the same pipe – it is a different trade-off, buying 8% more bore for six bar of class.

What is the difference between SDR 21 and SDR 26?

Two pressure classes and about 20% of the wall. SDR 21 is PN 8 and is normally irrigation or low-pressure distribution; SDR 26 is PN 6 and is almost always gravity sewer or stormwater, where the pressure rating is not the reason it was chosen. At dn315 the walls are 15.0 mm and 12.2 mm, and the bores are 285.0 mm and 290.6 mm.

Does the SDR change the outside diameter?

No. dn is fixed by the size and the SDR only moves the bore. A dn315 SDR 11 and a dn315 SDR 26 pipe have the same 315 mm outside diameter and fit the same trench, the same clamps and the same outside-diameter fittings – what differs is the wall, the bore and the pressure class.

What is the wall thickness of a 12, 15, 18 or 24 inch HDPE pipe?

In the metric series: 12 inch is dn315 (28.6 mm at SDR 11, 18.7 mm at SDR 17), 18 inch is dn450 (41.0 / 26.5 mm), 24 inch is dn630 (57.3 / 37.4 mm). 15 inch is not a standard size in either the metric or the IPS series – the nearest are dn355 (14 inch) and dn400 (16 inch). The full chart is above.

Can I join SDR 11 pipe to SDR 17 pipe?

Yes, with a fitting moulded for both series, which is most of our water range – the size tables show 17/11/9 where one body covers all three. What you cannot do is assume the joint is PN 16: the rating follows the thinner wall, so an SDR 11 to SDR 17 joint is a PN 10 joint.

How do I convert an HDPE pipe size to inches?

Divide the outside diameter by 25.4. dn110 is 4.33 inch, dn315 is 12.40 inch, dn630 is 24.80 inch. The inch figure people quote is a nominal trade size, not the OD – 4 inch pipe is dn110 in the metric series and 114.3 mm in IPS, and the two are not interchangeable.

What pressure is SDR 17 rated for in gas?

6.3 bar for PE100 – not the PN 10 it carries in water. The gas design coefficient is 2.0 instead of 1.25, so the allowable stress drops from 8.0 to 5.0 MPa and the class with it. The operating limit (MOP) is set by the network operator on top of that, so quote the operator's figure when you order rather than the table value.