Every number on this page is either taken from the standard table or calculated from the two definitions that generate it: the wall is the outside diameter divided by the SDR, and the pressure class comes from the wall. Wall thickness, bore, unit weight and the mm-to-inch conversion sit side by side for dn20 to dn1600, in SDR 11, 17, 21 and 26 – the four series that cover almost every water, gas and irrigation line we quote fittings for.
What SDR means, and what it does not
SDR stands for standard dimension ratio: the outside diameter divided by the wall thickness. It is a ratio, not a measurement, and that single fact explains almost everything else on this page.
dn110 SDR 11: 110 ÷ 11 = 10.0 mm · dn110 SDR 17: 110 ÷ 17 = 6.47, nominal 6.6 mm
Because the ratio is fixed, the same SDR gives the same pressure class at every diameter. A dn315 SDR 11 pipe and a dn110 SDR 11 pipe are both PN 16, even though one wall is nearly three times the other. That is why a line is specified by SDR and not by wall thickness: one figure then covers the whole scheme, from the service connection to the trunk main.
Three things get confused with SDR, and they are not the same:
- PN is the pressure class. It is derived from the SDR, not the other way round.
- SN is ring stiffness, a different property, and it falls much faster than the wall as the SDR rises. An SDR 17 pipe is not just slightly more flexible than SDR 11 – the stiffness goes with the cube of the wall.
- Wall in mm is the number you measure, not the number you specify. Two pipes of the same dn and the same SDR may print a wall figure that differs by 0.1 mm depending on which edition of the table the maker worked from.
What SDR does not change is the outside diameter. dn is fixed; the SDR only moves the bore. That is why fittings are sized on dn and rated on SDR, and why a fitting ordered for the wrong series will still slide onto the pipe and still be wrong.
SDR to pressure rating
The pressure class follows from the wall through the thin-wall (Barlow) relationship, with the material's long-term strength divided by a design coefficient:
PE100, water, C = 1.25 → σ = 8.0 MPa → PN = 16 ÷ (SDR − 1)
PE100, gas, C = 2.0 → σ = 5.0 MPa → PN = 10 ÷ (SDR − 1)
Two consequences catch people out. The first is that gas and water are not the same pipe: the same SDR 11 body is PN 16 in water and PN 10 in gas, because the design coefficient doubles. The second is that PN assumes 20 °C and a 50-year life. Above 20 °C the class derates, and by 40 °C an SDR 11 line is no longer a PN 16 line – if the line runs warm, say so and we quote against the derated figure.
| SDR | Wall as % of OD | PN, water | psi | PN, gas (bar) | Where it is normally used |
|---|---|---|---|---|---|
| SDR 41 | 2.4% | PN 4 | 58 | 2.5 | Large outfalls, low-head gravity |
| SDR 33 | 3.0% | PN 5 | 73 | 3.1 | Very low pressure, gravity only |
| SDR 26 | 3.8% | PN 6 | 87 | 4.0 | Gravity sewers, stormwater |
| SDR 21 | 4.8% | PN 8 | 116 | 5.0 | Irrigation, low-pressure distribution |
| SDR 17 | 5.9% | PN 10 | 145 | 6.3 | Water distribution 4–8 bar; gas |
| SDR 13.6 | 7.4% | PN 12.5 | 181 | 7.9 | Water to 12.5 bar, process lines |
| SDR 11 | 9.1% | PN 16 | 232 | 10.0 | Pressure mains, 10 bar gas, slurry |
| SDR 9 | 11.1% | PN 20 | 290 | 12.5 | High pressure, penstock, industrial |
| SDR 7.4 | 13.5% | PN 25 | 363 | 15.6 | High-pressure industrial, temporary |
| SDR 6 | 16.7% | PN 32 | 464 | 20.0 | Highest pressure, specialist plant |
PN is the nominal class you order; the formula returns 16.0 bar for SDR 11 and 6.4 bar for SDR 26, which is sold as PN 6. Both are right – the class is rounded to the standard step, the calculation is not.
Read the table downwards and the trade-off is obvious: every step down in SDR buys pressure and costs bore. SDR 11 to SDR 17 is six bar of pressure class for about 8% more bore at the same outside diameter.
Wall thickness chart, dn20 to dn1600
The figures below are nominal wall, e = dn ÷ SDR, taken up to the next 0.1 mm – pipe is never rounded down, because a thin wall is a pressure problem and a thick one is only a cost problem. Where a published standard table differs it is by 0.1 mm, from rounding to a different step, and it does not change the SDR you order.
| dn / OD (mm) | SDR 26 | SDR 21 | SDR 17 | SDR 11 |
|---|---|---|---|---|
| 20 | 0.8 | 1.0 | 1.2 | 1.9 |
| 25 | 1.0 | 1.2 | 1.5 | 2.3 |
| 32 | 1.3 | 1.6 | 1.9 | 3.0 |
| 40 | 1.6 | 2.0 | 2.4 | 3.7 |
| 50 | 2.0 | 2.4 | 3.0 | 4.6 |
| 63 | 2.5 | 3.0 | 3.8 | 5.8 |
| 75 | 2.9 | 3.6 | 4.5 | 6.9 |
| 90 | 3.5 | 4.3 | 5.3 | 8.2 |
| 110 | 4.3 | 5.3 | 6.6 | 10.0 |
| 125 | 4.9 | 6.0 | 7.4 | 11.4 |
| 140 | 5.4 | 6.7 | 8.3 | 12.8 |
| 160 | 6.2 | 7.7 | 9.5 | 14.6 |
| 180 | 7.0 | 8.6 | 10.6 | 16.4 |
| 200 | 7.7 | 9.6 | 11.9 | 18.2 |
| 225 | 8.7 | 10.8 | 13.3 | 20.5 |
| 250 | 9.7 | 11.9 | 14.8 | 22.7 |
| 280 | 10.8 | 13.4 | 16.5 | 25.5 |
| 315 | 12.2 | 15.0 | 18.7 | 28.6 |
| 355 | 13.7 | 17.0 | 20.9 | 32.3 |
| 400 | 15.4 | 19.1 | 23.7 | 36.4 |
| 450 | 17.4 | 21.5 | 26.5 | 41.0 |
| 500 | 19.3 | 23.9 | 29.6 | 45.5 |
| 560 | 21.6 | 26.7 | 33.0 | 51.0 |
| 630 | 24.3 | 30.1 | 37.4 | 57.3 |
| 710 | 27.4 | 33.9 | 41.8 | 64.6 |
| 800 | 30.8 | 38.1 | 47.1 | 72.8 |
| 900 | 34.7 | 42.9 | 53.0 | 81.9 |
| 1000 | 38.5 | 47.7 | 58.9 | 91.0 |
| 1200 | 46.2 | 57.2 | 70.6 | 109.1 |
| 1400 | 53.9 | 66.7 | 82.4 | 127.3 |
| 1600 | 61.6 | 76.2 | 94.2 | 145.5 |
Two things worth checking before you use this as a buying table. First, the wall is nominal, and the manufacturing tolerance in EN 12201-2 and ISO 4427-2 is a plus tolerance on that nominal figure – so a pipe measured slightly under nominal on site is normal, and a pipe well under it is not. Second, the chart is arithmetic – e = dn ÷ SDR holds at every diameter, including combinations nobody fuses, such as dn20 at SDR 26 with a 0.8 mm wall. Where the wall gets that thin the joint, not the pressure, is the problem, and the practical range for each series starts higher up.
If what you have is an inch size rather than a dn, the conversion is further down the page – the short version is that the inch figure is a trade name and the outside diameter is the metric one. A 12 inch HDPE pipe is dn315: 28.6 mm wall at SDR 11, 18.7 mm at SDR 17, 15.0 mm at SDR 21.
SDR 21: the low-pressure workhorse
SDR 21 is PN 8 – 116 psi – and it exists for the jobs where the pump head is modest and the pipe run is long: irrigation mains, gravity-fed distribution, low-pressure rural networks. Against SDR 17 it gives up two bar of class and gains only 2.7% of bore at dn315, so nobody chooses it for the flow. The case for it is cost: the wall is 20% thinner, and PE pipe is priced by mass. Against SDR 11 the bore gain is 10.6%, which is where it becomes a hydraulic decision rather than a budget one.
The complication is on the fitting side. A dn110 SDR 21 pipe has a 5.3 mm wall, and a fitting moulded for SDR 17 expects 6.6 mm at the same diameter. The socket still fits – both are dn110 on the outside – but the fusion parameters and the body wall were designed around a thicker pipe. Our standard moulds are dimensioned for SDR 9, 11 and 17, which is the series column you will see on every fitting page; for an SDR 21 line we confirm the body size by size before quoting rather than assume the SDR 17 item will do.
SDR 26: gravity, not pressure
SDR 26 is PN 6, the thinnest wall in common use, and it is almost never chosen for its pressure rating. It is chosen for sewers, stormwater and outfalls, where the line runs full by gravity and the governing requirement is bore per euro of pipe rather than bar. At dn315 the bore is 290.6 mm against 257.8 mm in SDR 11 – 12.7% more diameter and 27% more cross-section for the same trench.
What it gives up is stiffness. Ring stiffness scales with the cube of the wall, so the drop from 28.6 mm to 12.2 mm at dn315 is not a 56% loss of stiffness but closer to 92%. That is fine in a properly bedded sewer and not fine under a road with shallow cover – which is the reason a SDR 26 line under traffic is usually specified with a granular surround or swapped to SDR 21.
Internal diameter: the number that sets flow
Outside diameter is fixed by dn, so every millimetre of wall comes straight out of the bore, and flow capacity goes with the square of the bore. This is where the SDR decision actually shows up in engineering numbers rather than in a pressure class:
| dn (mm) | SDR 26 | SDR 21 | SDR 17 | SDR 11 |
|---|---|---|---|---|
| 20 | 18.4 | 18.0 | 17.6 | 16.2 |
| 25 | 23.0 | 22.6 | 22.0 | 20.4 |
| 32 | 29.4 | 28.8 | 28.2 | 26.0 |
| 40 | 36.8 | 36.0 | 35.2 | 32.6 |
| 50 | 46.0 | 45.2 | 44.0 | 40.8 |
| 63 | 58.0 | 57.0 | 55.4 | 51.4 |
| 75 | 69.2 | 67.8 | 66.0 | 61.2 |
| 90 | 83.0 | 81.4 | 79.4 | 73.6 |
| 110 | 101.4 | 99.4 | 96.8 | 90.0 |
| 125 | 115.2 | 113.0 | 110.2 | 102.2 |
| 140 | 129.2 | 126.6 | 123.4 | 114.4 |
| 160 | 147.6 | 144.6 | 141.0 | 130.8 |
| 180 | 166.0 | 162.8 | 158.8 | 147.2 |
| 200 | 184.6 | 180.8 | 176.2 | 163.6 |
| 225 | 207.6 | 203.4 | 198.4 | 184.0 |
| 250 | 230.6 | 226.2 | 220.4 | 204.6 |
| 280 | 258.4 | 253.2 | 247.0 | 229.0 |
| 315 | 290.6 | 285.0 | 277.6 | 257.8 |
| 355 | 327.6 | 321.0 | 313.2 | 290.4 |
| 400 | 369.2 | 361.8 | 352.6 | 327.2 |
| 450 | 415.2 | 407.0 | 397.0 | 368.0 |
| 500 | 461.4 | 452.2 | 440.8 | 409.0 |
| 560 | 516.8 | 506.6 | 494.0 | 458.0 |
| 630 | 581.4 | 569.8 | 555.2 | 515.4 |
| 710 | 655.2 | 642.2 | 626.4 | 580.8 |
| 800 | 738.4 | 723.8 | 705.8 | 654.4 |
| 900 | 830.6 | 814.2 | 794.0 | 736.2 |
| 1000 | 923.0 | 904.6 | 882.2 | 818.0 |
| 1200 | 1107.6 | 1085.6 | 1058.8 | 981.8 |
| 1400 | 1292.2 | 1266.6 | 1235.2 | 1145.4 |
| 1600 | 1476.8 | 1447.6 | 1411.6 | 1309.0 |
At dn315, SDR 17 gives a 277.6 mm bore against 257.8 mm in SDR 11. That is 7.7% more diameter and 16% more cross-section – the same pump then moves the same flow at a lower velocity, and the friction loss over a kilometre drops by roughly a quarter. On a line where the pump is the expensive item, SDR 17 pays for itself; on a line where the pressure surge is the risk, it does not.
Unit weight, kg per metre
Weight is a freight and handling figure, and for PE it has a second use: the material is lighter than water at 0.95 g/cm³, so an empty pipe floats. On a submerged or high-water-table outfall the weight per metre is the starting point for the ballast calculation.
| dn (mm) | SDR 21 | SDR 17 | SDR 11 |
|---|---|---|---|
| 20 | 0.06 | 0.07 | 0.10 |
| 25 | 0.09 | 0.11 | 0.16 |
| 32 | 0.15 | 0.17 | 0.26 |
| 40 | 0.23 | 0.27 | 0.40 |
| 50 | 0.34 | 0.42 | 0.62 |
| 63 | 0.54 | 0.67 | 0.99 |
| 75 | 0.77 | 0.95 | 1.40 |
| 90 | 1.10 | 1.34 | 2.00 |
| 110 | 1.66 | 2.04 | 2.98 |
| 125 | 2.13 | 2.60 | 3.87 |
| 140 | 2.67 | 3.26 | 4.86 |
| 160 | 3.50 | 4.27 | 6.34 |
| 180 | 4.40 | 5.36 | 8.01 |
| 200 | 5.46 | 6.68 | 9.88 |
| 225 | 6.90 | 8.40 | 12.5 |
| 250 | 8.46 | 10.4 | 15.4 |
| 280 | 10.7 | 13.0 | 19.4 |
| 315 | 13.4 | 16.5 | 24.4 |
| 355 | 17.1 | 20.8 | 31.1 |
| 400 | 21.7 | 26.6 | 39.5 |
| 450 | 27.5 | 33.5 | 50.0 |
| 500 | 34.0 | 41.6 | 61.7 |
| 560 | 42.5 | 51.9 | 77.5 |
| 630 | 53.9 | 66.1 | 97.9 |
| 710 | 68.4 | 83.4 | 124.4 |
| 800 | 86.6 | 105.8 | 158.0 |
| 900 | 109.7 | 134.0 | 200.0 |
| 1000 | 135.6 | 165.4 | 246.9 |
| 1200 | 195.1 | 238.0 | 355.2 |
| 1400 | 265.4 | 324.0 | 483.5 |
| 1600 | 346.5 | 423.3 | 631.6 |
The figures are pipe only, calculated from the annulus area. A joint adds the fitting, a flange adds the steel ring, and water in the line adds about 1 kg per metre for every 1000 mm² of bore – which for a dn315 line is 60 kg/m against 16.5 kg/m of pipe. A flooded line weighs nearly four times what the pipe weighs, which is why a buoyancy check is done flooded and not empty.
mm and inches: the conversion, and the trap in it
Half the enquiries we get quote an inch size and half quote a dn, and they do not convert exactly. The inch figure is a nominal trade size; the outside diameter is the metric one in the table below. A 4 inch HDPE pipe is dn110, whose outside diameter is 110 mm – 4.33 inches, not 4.00.
| Nominal size | Metric dn | OD (mm) | OD (inch) | Wall, SDR 17 | Wall, SDR 11 |
|---|---|---|---|---|---|
| 1/2" | 20 | 20.0 | 0.79 | 1.2 | 1.9 |
| 3/4" | 25 | 25.0 | 0.98 | 1.5 | 2.3 |
| 1" | 32 | 32.0 | 1.26 | 1.9 | 3.0 |
| 1 1/4" | 40 | 40.0 | 1.57 | 2.4 | 3.7 |
| 1 1/2" | 50 | 50.0 | 1.97 | 3.0 | 4.6 |
| 2" | 63 | 63.0 | 2.48 | 3.8 | 5.8 |
| 2 1/2" | 75 | 75.0 | 2.95 | 4.5 | 6.9 |
| 3" | 90 | 90.0 | 3.54 | 5.3 | 8.2 |
| 4" | 110 | 110.0 | 4.33 | 6.6 | 10.0 |
| 5" | 140 | 140.0 | 5.51 | 8.3 | 12.8 |
| 6" | 160 | 160.0 | 6.30 | 9.5 | 14.6 |
| 8" | 200 | 200.0 | 7.87 | 11.9 | 18.2 |
| 10" | 250 | 250.0 | 9.84 | 14.8 | 22.7 |
| 12" | 315 | 315.0 | 12.40 | 18.7 | 28.6 |
| 14" | 355 | 355.0 | 13.98 | 20.9 | 32.3 |
| 16" | 400 | 400.0 | 15.75 | 23.7 | 36.4 |
| 18" | 450 | 450.0 | 17.72 | 26.5 | 41.0 |
| 20" | 500 | 500.0 | 19.69 | 29.6 | 45.5 |
| 24" | 630 | 630.0 | 24.80 | 37.4 | 57.3 |
| 28" | 710 | 710.0 | 27.95 | 41.8 | 64.6 |
| 32" | 800 | 800.0 | 31.50 | 47.1 | 72.8 |
| 36" | 900 | 900.0 | 35.43 | 53.0 | 81.9 |
| 40" | 1000 | 1000.0 | 39.37 | 58.9 | 91.0 |
| 48" | 1200 | 1200.0 | 47.24 | 70.6 | 109.1 |
Why the fitting has to match the SDR
This is a fittings site, so the practical question behind every SDR query is: what do I put on the end of this pipe? Four things change with the series, and three of them are invisible once the joint is made.
| SDR 11 pipe | SDR 17 pipe | What goes wrong if mismatched | |
|---|---|---|---|
| Butt fusion body wall | 9.1% of OD | 5.9% of OD | The weld is not full-section on the thinner side; the joint rating follows the thin wall, not the fitting |
| Heating and cooling time | Longer | Shorter | Using the SDR 11 chart on SDR 17 pipe overheats it; the bead rolls back and the wall thins at the joint |
| Electrofusion parameter set | One set | Another set | The coil energy is matched to the melt volume; the wrong set gives a cold or a blown weld |
| Socket depth and insertion mark | Set by the series | Set by the series | Pipe pushed short of the mark leaves an unfused band at the bottom of the socket |
Our range is dimensioned for SDR 9, 11 and 17, and each fitting page carries the series in its size table rather than assuming one. If a line mixes series – SDR 17 main with an SDR 11 tie-in, which is common where a new connection meets an old main – the transition is made with a fitting moulded for both, and the rating of the joint is the lower of the two.
Which SDR for which job
| Application | Normal working pressure | SDR | What to watch |
|---|---|---|---|
| Municipal water distribution | 4 – 8 bar | SDR 17 | Surge on long rising mains |
| Booster and transmission mains | 10 – 16 bar | SDR 11 | Pump start/stop surge; anchor at bends |
| Service connections, in-building | up to 10 bar | SDR 11 | Small diameters, tight radii, socket fusion to dn63 |
| Gas distribution | up to 4 bar MOP | SDR 11 or 17 | The operator's MOP and test pressure decide it |
| Irrigation, agriculture | 2 – 6 bar | SDR 21 | UV exposure, valve surge at the end of the line |
| Gravity sewer, stormwater | nil | SDR 26 | Ring stiffness under traffic load and cover depth |
| Mine slurry, tailings | 8 – 16 bar | SDR 11 | Wear allowance – the wall is the wear life |
Where the table gives two series, the deciding factor is usually the network operator's standard rather than the physics. Where it gives one, taking the next series up is a cost decision, not a safety one – the exception is gravity work, where a heavier wall buys stiffness, not pressure.
Frequently asked questions
What does SDR 11 mean?
SDR 11 means the outside diameter is 11 times the wall thickness, so the wall is dn ÷ 11 – 10.0 mm on a dn110 pipe. For PE100 in water service it is the PN 16 class: 232 psi at 20 °C. The same ratio holds at every diameter, which is why one SDR figure can specify a whole network.
Is SDR 11 stronger than SDR 17?
In pressure terms yes: SDR 11 is PN 16 and SDR 17 is PN 10 for PE100 water, because the wall is 9.1% of the outside diameter instead of 5.9%. In stiffness terms the gap is much wider, since ring stiffness follows the cube of the wall. SDR 17 is not a weaker version of the same pipe – it is a different trade-off, buying 8% more bore for six bar of class.
What is the difference between SDR 21 and SDR 26?
Two pressure classes and about 20% of the wall. SDR 21 is PN 8 and is normally irrigation or low-pressure distribution; SDR 26 is PN 6 and is almost always gravity sewer or stormwater, where the pressure rating is not the reason it was chosen. At dn315 the walls are 15.0 mm and 12.2 mm, and the bores are 285.0 mm and 290.6 mm.
Does the SDR change the outside diameter?
No. dn is fixed by the size and the SDR only moves the bore. A dn315 SDR 11 and a dn315 SDR 26 pipe have the same 315 mm outside diameter and fit the same trench, the same clamps and the same outside-diameter fittings – what differs is the wall, the bore and the pressure class.
What is the wall thickness of a 12, 15, 18 or 24 inch HDPE pipe?
In the metric series: 12 inch is dn315 (28.6 mm at SDR 11, 18.7 mm at SDR 17), 18 inch is dn450 (41.0 / 26.5 mm), 24 inch is dn630 (57.3 / 37.4 mm). 15 inch is not a standard size in either the metric or the IPS series – the nearest are dn355 (14 inch) and dn400 (16 inch). The full chart is above.
Can I join SDR 11 pipe to SDR 17 pipe?
Yes, with a fitting moulded for both series, which is most of our water range – the size tables show 17/11/9 where one body covers all three. What you cannot do is assume the joint is PN 16: the rating follows the thinner wall, so an SDR 11 to SDR 17 joint is a PN 10 joint.
How do I convert an HDPE pipe size to inches?
Divide the outside diameter by 25.4. dn110 is 4.33 inch, dn315 is 12.40 inch, dn630 is 24.80 inch. The inch figure people quote is a nominal trade size, not the OD – 4 inch pipe is dn110 in the metric series and 114.3 mm in IPS, and the two are not interchangeable.
What pressure is SDR 17 rated for in gas?
6.3 bar for PE100 – not the PN 10 it carries in water. The gas design coefficient is 2.0 instead of 1.25, so the allowable stress drops from 8.0 to 5.0 MPa and the class with it. The operating limit (MOP) is set by the network operator on top of that, so quote the operator's figure when you order rather than the table value.
- PE100 fittings catalogue 2026 - the same reference tables, printed, with every family size table
- ISO 4437 and EN 1555 for gas – the standard behind a gas order, part by part, with the design coefficient that separates gas from water
- SDR 11 HDPE fittings – every family we mould at SDR 11, with the sizes and size pairs
- HDPE pipe fittings specifications – all 65 families on one page, with the wall series for each
- How the fittings are grouped by jointing method – the index page
- Dimension charts – tee · elbow · reducer · flange adaptor · end cap
- Applications – water supply · gas · irrigation · drainage and stormwater · mining
- How HDPE pipes are joined – and which method each series needs