Every HDPE pipe fitting we mould, in one place: 65 families and 1,366 size entries from dn20 to dn1600, grouped by the way the joint is made rather than by the shape of the part. If the joint method is already decided, the group is one table down. If it is not, start with the selection table, because it is the decision that sets the price.

65mould families
1,366size entries
dn20–dn1600size range
SDR 9/11/17wall series

The range, sorted by the joint and not by the shape

An HDPE pipe fitting is not one product. The same 90° elbow exists as an electrofusion body with a heating coil moulded into the socket, as a plain butt fusion body matched to the pipe wall, and as a socket fusion body with two female sockets for a heating iron. Three different parts, three different tools, three different prices, and on any given site only one of them can actually be installed.

That is why this catalogue is sorted by joint method rather than by shape. A page that lists "elbows" as a category tells a buyer nothing, because the shape is the last thing that decides the order and the joint is the first.

Everything we mould is on these tables: 65 families and 1,366 size entries, dn20 to dn1600, all PE100. A size is either something we hold a mould for or it is not on the page. We do not sell pipe, so the range stops at the fitting: what goes into each joint is a pipe end of the matching outside diameter and wall series.

Choosing the joint, which is where the price is decided

Most enquiries arrive with the diameter fixed and the joint method left open. That is the wrong way round. At any given diameter the joint method changes the cost per joint by a factor of two or three, and it changes who is able to make the joint at all.

The four ways a PE fitting is joined to a pipe, and what each one asks of the site
MethodWorking rangeWins whenCosts you whenWhat it needs on site
Socket fusiondn20–dn63Small bore with many joints, in a pit or indoors. There is no coil in the fitting, so the fitting is the cheapest per piece of the three.The iron has to reach all the way round the joint, and the range stops at dn63. Not accepted for gas in most markets.Heating iron, reamer, alignment jig
Electrofusiondn20–dn1400Tie-ins, repairs, and any joint where the pipe cannot be moved. Often the only method that works in a narrow wet trench.Every joint needs a scraped surface, a control box and a power supply. The coil is inside the fitting, so the piece price is the highest of the three.Control box, scraper, clamp
Butt fusiondn20–dn1600New work on open ground, and the only method above dn1400. Cheapest per joint once the diameter is large enough to amortise the machine.Needs clear room along the pipe axis and a two-man crew; impossible against a wall, in a flooded trench, or on a line that cannot be pulled back.Machine, facer, heating plate, crane above dn630
Flanged or mechanicaldn25–dn1600Joining to steel, valves, pumps, meters and plant. It is also the one break in a line that can be opened again.A gasket and bolts are a maintenance item, and the flange is the point where a buried line is most likely to weep.Torque wrench, gasket, steel backing ring

The crossover from electrofusion to butt fusion is not a diameter, it is a site condition. On 400 m of dn315 main across a field, butt fusion is cheaper per joint and faster. On the same main, ten metres from a wall in a trench with water in it, a butt fusion machine cannot be set up at all, and the electrofusion coupling that costs three times as much per piece is the only thing that will close the line.

So the useful question is not which fitting is cheapest. It is how many of these joints can be made with the equipment that will actually be on site, and what the other joints cost when they cannot.

One elbow, three bodies: what actually changes

The 90° elbow sits in every one of our mould sets. Put the three versions side by side at the same nominal size and they differ in everything except the angle.

Three 90° elbows, indicative for SDR 11 PE100
Socket fusion, dn63Electrofusion, dn315Butt fusion, dn315
BodyTwo female sockets moulded to socket depthSocket with a resistance coil wound inside and two terminals on the outsidePlain ends, moulded to match the pipe wall
How the joint is madeBoth parts heated on an iron, then pushed together and heldCurrent through the coil heats fitting and pipe from the interface outwardsBoth ends faced flat, heated on a plate, then pressed together and held
Joint cycleThe shortest: heating plus a cooling holdThe middle: the box runs the cycle, then a cooling hold before the clamp comes offThe longest: facing, heating, changeover, then a pressure hold
EquipmentIron and jigControl box and scraperMachine, facer and crane
Access neededAll the way round the jointOne side is enoughAlong the axis, both sides
Pressure ratingThe pipe's, if the SDR matchesThe sameThe same
Typical failureA cold joint from too short a heatA wet or unscraped surface, or the wrong cycle for the sizeA misaligned facer, or the clamp released before the hold is over

Notice what does not change: the pressure rating. All three carry the same PN as the pipe they join. What changes is the risk profile, and the risk profile is what a tender should be written around.

The catalogue, family by family

Six groups below, in the order they appear on the summary table. Each row is a mould family, so the size range and the number of entries are what we actually run rather than a nominal capability. The full dimension table for any family is on the specifications page; this is the index to it.

The whole range in one table: 65 mould families, 1,366 size entries
GroupFamiliesSize rangeEntriesMoulded forWhat it covers
Electrofusion fittings9dn20–dn1400282SDR 9 / 11 / 17Couplings, elbows, tees, reducers, flange adaptors and end caps for water and general pressure lines.
Electrofusion saddles5dn63–dn31551SDR 11Bypass, clamp and end plug outlets that take a branch off a main without cutting it.
Butt fusion fittings9dn20–dn1600356SDR 11 / 17Reducers, elbows, tees, lateral tees, end caps, flange adaptors and rings; the range that reaches dn1600.
Socket fusion fittings13dn20–dn6396SDR 11Small-bore couplings, elbows, tees, end caps and six threaded adaptors, dn20 to dn63.
PE100 gas electrofusion11dn20–dn400213SDR 11The separate gas mould set: couplings, tees, elbows, caps, saddles and flange adaptors to dn400.
PE100 gas butt fusion9dn20–dn630225SDR 11 / 17Gas butt fusion to dn630, including the condensate trap and the cross.
PE ball valves3Ø32–Ø35527fusion endStandard and vented ball valves, Ø32 to Ø355, with a PE spigot on both ends.
Steel-to-PE transitions6dn25–dn355116SDR 11 / 17Straight and bent transitions, plain or threaded steel end, for pumps, meters and steel mains.

Electrofusion fittings, dn20 to dn1400

Nine families and 282 size entries, moulded for SDR 9, 11 and 17 with the series listed per size. This is the group that carries the awkward joints: the tie-in at the end of a day's laying, the repair in a trench that is already full of water, the branch nobody could reach with a machine.

The straight coupling is the widest electrofusion body we mould at dn1400. The equal tee stops at dn630, not because a larger tee is impossible but because the coil and terminal layout stops being practical above it, which is why every large tee in this catalogue is a butt fusion part.

Electrofusion fittings: nine families, SDR 9, 11 and 17
BodySize rangeSize entriesWhat it is for
Straight couplingdn20–dn140032The workhorse: a straight joint between two pipe ends, in the full size range.
90° elbowdn25–dn90027A moulded long-radius body. A bent pipe thins at the outside of the bend; a moulded elbow does not.
45° elbowdn25–dn90026Half the turn of the 90, and the usual choice for a line following ground contour.
Reducing couplingdn32–dn45045Steps the line down in one joint instead of a reducer and a spool piece.
Equal teedn25–dn63025Splits a main into two identical legs. Stops at dn630.
Reducing teedn25–dn63079The largest family in the electrofusion range. The branch size is always listed second, dn110 × 63 for a dn110 run.
Flange adaptordn50–dn80019PE on one end, a machined flange face on the other. Always used with the steel ring below.
End capdn40–dn31511Closes a line for a pressure test, or terminates a branch that will be extended later.
Flange steel ringdn50–dn80018The coated steel ring that backs the adaptor. Sold as a pair with it, because a PE flange is never complete on its own.

Saddles, dn63 to dn315

A saddle takes a branch off a main without cutting it: the outlet is fusion-welded onto the outside, the hole is drilled through it, and the main keeps running. That is the only way to add a branch to a line that is already in service, and it is the reason saddles are specified by the size of the main first and the branch second.

Five families, and the old and new model moulds are listed separately on purpose. The two models have different dimensions, so a tender that names one cannot be satisfied with the other, and a mixed delivery of both models will not sit at the same height on the same main.

Electrofusion saddles: old and new model moulds
BodySize rangeSize entriesWhat it is for
Bypass saddle, old modeldn63–dn31510Outlet closed by a plug, so the branch can be drilled and capped and connected whenever the taker is ready.
Bypass saddle, new modeldn63–dn22516The same function on the later mould, with a shallower body.
Clamp saddle, old modeldn63–dn3159Two-part clamp with the outlet moulded into the upper half, for a main with no room to move.
Clamp saddle, new modeldn63–dn2259The later clamp body, same purpose, different stack height.
Saddle end plugdn63–dn3157Seals an outlet that will not be used, or a hole where the branch was cancelled after drilling.

Butt fusion fittings, dn20 to dn1600

Nine families and 356 size entries, in SDR 11 and 17. This is the group that reaches the sizes a transmission main needs, and it is also the group that carries the small sizes: the 90° elbow starts at dn20, so a butt fusion line does not have to change method at the bottom of the range.

The reducing tee is the largest single family in the whole catalogue at 102 combinations, which says something about how lines are actually built: most of the fitting count on a real project is branches, not joints.

Butt fusion fittings: nine families, SDR 11 and 17
BodySize rangeSize entriesWhat it is for
Reducerdn50–dn63078Concentric reducer. Above dn630 a reduction is normally machined or fabricated rather than moulded.
90° elbowdn20–dn160031From dn20 upwards, so the small sizes of a butt fusion system are covered.
45° elbowdn50–dn160027The same body geometry as the 90 with half the turn, up to dn1600.
Equal teedn40–dn160027Full size on all three ends, dn40 to dn1600.
Reducing teedn50–dn1600102The largest family in the catalogue. Branch size listed second, always.
Lateral tee, 45°dn63–dn1606A branch that leaves at 45° rather than 90°: lower loss, better pigging, and a smoother flow into the branch. dn63 to dn160 only.
End capdn20–dn160031The largest end cap we mould, to dn1600. Used for a test closure or a staged extension.
Flange adaptordn40–dn160028To dn1600, with the flange face machined after moulding so the bolt circle is true.
Flange steel ringdn40–dn120026The backing ring for the adaptor. Its size follows the flange standard, not the pipe.

Socket fusion fittings, dn20 to dn63

Thirteen families, all in SDR 11, and all at the small end. Socket fusion is the cheapest way to make a joint in this range, and the only one that needs nothing more than a heating iron and a jig.

The six threaded families are what turns socket fusion into a system rather than a set of joints: they are how a PE line ends at a brass valve, a steel riser or a filter housing without a separate transition fitting. A female threaded coupling takes a male thread, a male threaded coupling goes into a female one, and the same split exists for elbows and tees, which is why there are six of them.

Socket fusion fittings: thirteen families, SDR 11
BodySize rangeSize entriesWhat it is for
Couplingdn20–dn636Straight joint, both ends socket.
Reducing couplingdn25–dn6315Steps the line down within the small-bore range.
Tee, equal and reducingdn20–dn6321Equal and reducing tees in the same mould set; the reducing version lists the branch second.
45° elbowdn20–dn636For a line following a trench bend without a joint every half metre.
90° elbowdn20–dn636The standard turn at a chamber wall or a riser.
End capdn20–dn636Terminates a small branch, or closes a line for a test.
Threaded adaptors, female and maledn20–dn6336Couplings, elbows and tees with a BSP thread on one end. Six families, because female and male are separate moulds for each shape.

The PE100 gas range, dn20 to dn630

Twenty families and 438 size entries, in a separate mould set. The fittings have the same nominal sizes as the water range and look similar, but they are moulded, tested and recorded as gas product, and they are listed in their own tables because a gas line is specified and audited differently.

Two facts shape this group. The electrofusion gas range stops at dn400, so a gas main above that is butt fusion; and the gas range is SDR 11 throughout, with SDR 17 on part of the butt fusion list only. Where a water line can choose its pressure class by changing series, a gas line usually cannot: the series is fixed by the operating pressure band in the local code.

Two bodies exist only in the gas range. The condensate trap is a tee with the branch closed and a sump below the run, for the low points where a gas main picks up moisture. The cross is a four-way body in dn63 to dn90, for a compact manifold where two tees would not fit.

The PE100 gas range: twenty families in a separate mould set
BodySize rangeSize entriesWhat it is for
Electrofusion straight couplingdn20–dn40020Straight joint to dn400. One dn400 entry is also listed in SDR 17.
Electrofusion reducing couplingdn32–dn40039Steps a gas line down without a spool piece.
Electrofusion tee, equal and reducingdn25–dn40072Branches on an electrofusion gas main, to dn400.
Electrofusion elbow, 90° and 45°dn25–dn40032The two turns, same body geometry as the water range.
Electrofusion end capdn50–dn31510Test closure and branch termination.
Electrofusion saddle, clamp, bypass and end plugdn63–dn40033Service tees off a live gas main, plus the plug that seals an unused outlet.
Electrofusion flange adaptordn110–dn4007Where the PE line meets a steel valve or a regulator.
Butt fusion reducerdn75–dn40055The gas reduction range, dn75 to dn400.
Butt fusion elbow, 90° and 45°dn75–dn40026Turns on a gas main laid by machine.
Butt fusion tee, equal and reducingdn50–dn63088The branch count on a gas distribution main, equal to dn630 and reducing to dn400.
Butt fusion stub enddn40–dn63018The PE half of a flanged joint; the steel backing ring is shared with the water range.
Butt fusion end capdn20–dn63024Closure to dn630.
Condensate trapdn63–dn40011A tee with a sump: the low point of a gas main, where the moisture collects and is drawn off.
Butt fusion crossdn63–dn903Four-way body in dn63 to dn90, for a manifold where two tees will not fit.

Isolation and transitions, dn25 to dn355

Nine families that are not fittings in the strict sense, but that a PE line cannot be finished without: the valves that isolate a branch, and the transitions that hand the line over to steel at a pump, a meter or a steel main.

The ball valves have a PE spigot at both ends, so they are fused into the line like any other fitting and there is no flange to leak. The vented versions have a port that relieves the cavity between the two seats, which is a gas-network requirement rather than a water one: a liquid cannot be compressed into that cavity, a gas can.

The transitions are supplied as straight or bent, with a plain steel end for welding or a threaded end for screwing. The bent versions are the ones that take the line from a buried depth up to a meter or a riser in one piece, with the steel length stated in the family name so there is no argument on site about what arrives.

Ball valves and steel-to-PE transitions
BodySize rangeSize entriesWhat it is for
Standard ball valveØ32–Ø35511Fusion ends, full bore, for isolation on a water or gas branch.
Ball valve, single ventØ63–Ø3558One vent port to relieve the body cavity; the usual gas specification.
Ball valve, double ventØ63–Ø3558Two vent ports, for a valve that may be drained or vented from either side.
Straight transition, plain steel, SDR 11dn25–dn35536PE socket on one end, bare steel on the other, for welding into a steel main or a pump flange.
Straight transition, plain steel, SDR 17dn90–dn35517The same on a thinner wall, for a low-pressure line.
Bent transition, plain steel, 1.1 mdn25–dn6316Steel length 0.3 m up plus 0.8 m out; the standard riser for a buried service.
Bent transition, threaded, 1.1 mdn25–dn6314The same bend with a screwed steel end, for a meter or a small valve.
Bent transition, plain steel, 1.5 mdn25–dn6319Steel length 0.3 m up plus 1.2 m out, for a deeper burial or a taller riser.
Bent transition, threaded, 1.5 mdn25–dn6314The long bend with a screwed end.

Pressure class: a fitting has no rating of its own

A PE fitting does not carry a pressure rating the way a valve does. It inherits the rating of the pipe it is fused to, and it inherits it only when the wall series matches. An SDR 11 fitting on an SDR 17 pipe is not a stronger joint, it is a mismatched one, and the mismatch shows up as a step on the bore and a stress concentration at the fusion interface.

SDR is the outside diameter divided by the wall thickness, so a lower number means a thicker wall. At dn110 in PE100 water at 20 °C, SDR 17 is a 6.6 mm wall at PN 10, SDR 11 is 10 mm at PN 16 and SDR 9 is 12.3 mm at PN 20. Those ratings fall away with temperature and with the design factor a code imposes, which is why a gas line is specified by SDR and by an operating pressure band rather than by a PN number.

The series covered differ by group, and that is a real constraint rather than a footnote. Socket fusion is moulded in SDR 11 only, so a socket fusion line is a PN 16 line and nothing else. The water electrofusion range covers SDR 9, 11 and 17 in the sizes where each is made. The butt fusion range carries 11 and 17 across most of its size list. The gas electrofusion range is SDR 11 throughout. The SDR column on the summary table is therefore the first thing to check against your pipe schedule, before the size.

Two numbers, both needed. A "dn315 fitting" is not an order. A dn315 SDR 11 coupling and a dn315 SDR 17 coupling are different parts with different weights and different prices, and one will not fuse correctly to the other's pipe. Quote both.

If you are converting between SDR, PN and wall thickness, our SDR to PN converter does the arithmetic for PE100 at the service temperature you enter.

Where the range stops, and what to do instead

A catalogue that claims everything is no use for tendering. These are the ceilings in our own tooling, listed so that a specification can be written around them rather than into them.

  • Socket fusion stops at dn63. Above that the socket depth and the iron size make it impractical; the joint becomes electrofusion.
  • Electrofusion equal tees stop at dn630, but the straight coupling reaches dn1400. A dn800 tee is a butt fusion part. There is no electrofusion version and there is not going to be one.
  • Butt fusion crosses are gas-series only, dn63 to dn90. Above that a cross is two tees, or a fabricated spool.
  • 45° lateral tees stop at dn160. A larger lateral is a reducing tee with an elbow, or a fabricated assembly.
  • Ball valves stop at Ø355. Above that the isolation is a flanged valve with a PE stub end and a steel ring.
  • Steel-to-PE transitions stop at dn355. Above that the usual detail is a PE flange adaptor bolted to a steel flange, which is two standard parts rather than one special.
  • Water saddles stop at a dn315 main; gas saddles at dn400. A larger branch is a tee cut into the line, not a saddle onto it.
  • Electrofusion reducing couplings stop at dn450. Above that a reduction is butt fusion.

None of these is a limit of polyethylene, and most of them are a limit of the mould. If a project needs a size outside the list, say so: machined and fabricated options exist, and they are quoted as specials rather than read off a table. What we will not do is put a size on a quotation that we cannot actually mould.

Standards, marking, and what a certificate covers

Fittings are specified by the part of a standard that covers fittings, not the part that covers pipe, and confusing the two is the most common mistake in a tender document. ISO 4427-2 is pipe and ISO 4427-3 is fittings; EN 12201-3 is the European fittings part; GB/T 13663.3 is the Chinese one. A certificate for the pipe is not a certificate for the fitting.

For gas the equivalent set is ISO 4437-3 and EN 1555-3, with GB 15558.2, and ISO 8085 where a specifier cites the moulded-fitting requirements instead. The families differ in their test lists more than in their dimensions, which is why a fitting can carry a CE mark and still fail a tender that names EN 12201-3 clause by clause. If your document names a standard, send us the clause and we will confirm against it before quoting rather than after.

Every fitting is permanently marked with the nominal size, the SDR series, the material designation, our name and a traceability reference. On a gas order the batch record travels with the delivery, because a fusion log is only worth keeping if it can be tied back to a batch of fittings.

Which certificates we hold, and for which families, is on the certificate page. The clause-by-clause comparison of ISO, EN and GB is on the standards comparison page.

If you already know the size

This page is organised by joint method, which is the right order for a new line and the wrong one for a tender that already says dn315. The size charts are the other way in:

What moves the price of a fitting

Four things, in this order: the weight of the part, the size of the mould it comes out of, the quantity, and the paperwork.

Weight. Fittings are sold by the kilogram at heart. The wall at SDR 9 is nearly twice the wall at SDR 17 on the same diameter, so a dn110 SDR 9 elbow carries close to twice the material of the SDR 17 version and is priced accordingly. A PE100-RC compound, or a gas grade with its own test regime, costs more per kilogram than the standard water compound, before any fitting is moulded.

The mould. Price per piece is not linear in diameter. A dn800 tee comes off a machine of a different order of size from a dn63 coupling, runs a few hundred pieces a year rather than a few hundred thousand, and has to pay back a mould that may have cost more than the machine time on it. That is why the largest sizes on these tables are quoted per order rather than listed.

Quantity and packing. Most fittings ship in cartons on a pallet, and the carton quantity is set by the mould and by the weight a carton can take. Homogeneous pallets cost less to pick than mixed ones, and a full container is a different price from a part container.

Paperwork. A gas order carries batch traceability, a fusion protocol and often a third-party inspection. That is real cost, and it is not in the list price.

List price is a starting point, not a quote. Our published lists are RMB per piece at ex-works quantities. A quotation depends on the quantity, the compound, the packing and the port. Send the item, the size and the quantity and we will price it; the 2026 gas and water price lists are on the download page in Excel and PDF if you want to see the shape of the numbers first.

What to put in an enquiry

Six lines are enough for us to quote a mixed order without a second round of questions:

  1. The application: gas, potable water, irrigation, effluent or industrial. It decides the compound and the test regime, not only the price.
  2. The joint method for each item, or "cheapest for this diameter" if you would rather we chose.
  3. The size and the SDR, per item. A size without a series is half a specification.
  4. The quantity per size, and whether the order will repeat.
  5. The standard the project cites, and whether a certificate pack is needed with the delivery.
  6. The destination port, because it decides the packing and whether a full container is being planned.

If you have a bill of quantities in Excel, send it as it is. We will come back with the gaps marked rather than with a request to retype it in our format. For the packing side, the container loading calculator gives you the carton and pallet counts before the order is placed.

Frequently asked questions

Are HDPE pipe fittings the same as PE fittings?

In practice yes. HDPE is high-density polyethylene, and PE100, which is what every fitting on these tables is moulded from, is a high-density grade. PE100 is a classification rather than a brand: it means a minimum required strength of 10 MPa at 50 years and 20 °C, tested to ISO 12162. PE80 exists and is still used on older gas networks, but it is not in this catalogue.

Do the fitting and the pipe have to be the same SDR?

Yes, for a fusion joint. The fitting is moulded to accept a specific wall, and an SDR 11 fitting on an SDR 17 pipe leaves a step on the bore and a stress concentration where the two walls meet. The pressure rating of a joint comes from the pipe, so a thicker fitting does not raise it; it only makes the joint wrong. The SDR column on the summary table is the first thing to check.

Which joint method is cheapest?

It depends on the diameter and on the site, not on the fitting alone. Socket fusion is cheapest per joint at dn63 and below. Above about dn315 on open ground, butt fusion wins because the machine is amortised over the diameter. Electrofusion is the most expensive per piece and often the cheapest overall, because it is the only method that works in a tight trench or on a line that cannot be moved.

What is the largest HDPE fitting you make?

dn1600, as a butt fusion elbow, tee, end cap and flange adaptor. Above that the line is usually joined by a PE flange adaptor bolted to a steel flange. Electrofusion reaches dn1400 on the straight coupling and dn630 on the tee, because the coil arrangement stops being practical above those sizes.

Can water fittings be used on a gas line?

Not on a line governed by a gas code. Our gas range comes from a separate mould set, is tested to the gas standard and is recorded as gas product, and the two ranges are listed and shipped separately. Whether a water-marked fitting may be used in gas service is decided by the code that governs the line, and in most markets the answer is no.

Do you supply the fusion equipment as well?

Yes. There are three families of welding machine in the catalogue, for socket, electrofusion and butt fusion, and they are listed with the same size ranges as the fittings they join. A buyer taking a complete system usually takes the machine with the first order, because the joint procedure and the fitting are specified together.

Can I mix fittings from different manufacturers?

Within one standard and one SDR the dimensions are standardised, so the parts will go together and a joint can be made. What does not mix is the responsibility: if two suppliers' parts fail at the same joint, neither will own it. System certification is issued to a pipe and fitting combination, not to a fitting alone, which is the practical reason to keep one source for a whole line.