Reading An Electrofusion Fitting Nameplate: Voltage, Time And Stages

Nov 03, 2026

Leave a message

Electrofusion · Nameplate
Reading An Electrofusion Fitting Nameplate: Voltage, Time And Stages

A fitting label carries a dozen numbers. Four of them matter, and one of those is the one most often read wrong: the mode.

Reading the label is a five-minute skill, but it decides whether the cycle delivers the heat the fitting was designed for. The sequence the label feeds into is in electrofusion welding procedure.

4
Values that decide the cycle
39.5 V
Common PE100 default
0.5 V
Permitted output deviation
Values

The Four Values To Read

Value Where it appears What you do with it
Fusion mode V or A beside the voltage or current column Select constant voltage or constant current
Voltage or current for example 39.5 V, or 3.0 A Enter exactly as printed
Time per stage for example 70 s, 200 s Enter per stage, not as a total
Cooling time for example 15 min Governs handling and testing, not the melt cycle
Number of stages Number of parameter rows Set the stage count before entering values

If a label shows no voltage, 39.5 V is the common default for PE100 electrofusion fittings, but confirm with the fitting manufacturer before welding gas pipe.

Mode

Constant Voltage Or Constant Current

  • V means constant voltage. The machine holds voltage across the wire regardless of resistance. This is the standard for PE electrofusion fittings.
  • A means constant current. The machine holds current. Used on some steel-reinforced and specialised fittings.

Selecting the wrong mode is not a small error. Constant voltage on a constant-current fitting drives the current high and can burn the wire through; constant current on a constant-voltage fitting under-heats and produces a joint that looks complete and is not fused. Because nothing on the fitting changes outwardly, the mistake is only found by cutting a joint open.

Stages

One Stage Or Several

Single-stage fittings are typical for plain PE sockets, couplers and saddles. Multi-stage fittings appear on steel-reinforced skeleton fittings and larger diameters, where the wire is wound in separate zones and each zone needs its own voltage and time.

Count the parameter rows on the label: three rows means three stages. Enter the stage count before entering values, because on most machines changing the stage count resets the parameter table.

Checks

Three Practical Checks Before You Start

  • Is the fitting voltage inside your machine's output range? A 3.5 kW unit covers most fittings to dn315, 8 kW to dn630, 12 kW for 1 m and above. A fitting needing 48 V cannot be welded on a machine that tops out at 40 V, whatever the label says.
  • Is the barcode readable? Scanning removes transcription errors and is the default on gas work. A worn barcode means manual entry, which means a second person reading the numbers back.
  • Does the label match the fitting in your hand? Mixing a label from one size onto another is rare, but it happens in site stores.

Machine capability against fitting range is the pairing that goes wrong most often on multi-diameter sites: electrofusion machines from 3.5 kW to 12 kW cover the range, and the output tolerance is what decides whether the label can be honoured.

Specification

Reading The Label As A Specification

Each row is a promise from the fitting manufacturer: at this voltage, for this time, the wire delivers enough heat to fuse the stated pipe SDR. Your job is to reproduce the electrical conditions.

If the machine cannot hold the setpoint within 0.5 V, the fitting is not being welded to its specification, whatever the indicator shows. That condition is diagnosed in electrofusion output open circuit.

FAQ

Frequently Asked Questions

What if the label says 39.5 V and my machine reads 38.9 V?

0.6 V is outside the 0.5 V window. Check supply voltage stability first, then the output cable and terminals. Do not weld and hope.

Can I extend the welding time if it is very cold?

Only within limits set by the fitting manufacturer. Some allow a small percentage increase, many specify a temperature-compensated machine function instead. Do not improvise on gas fittings.

What is the cooling time for?

Removing clamps and handling. The joint must cool undisturbed, and the label value is a minimum, not a target.