Electrofusion Branch Saddle

Electrofusion Branch Saddle

An electrofusion branch saddle for adding a new outlet to an existing network without re-routing any pipe. The branch is fused onto the already-laid main exactly where the new demand appears, so growth is met by extending a lateral rather than digging up and re-ordering a whole run.
Send Inquiry

Electrofusion Branch Saddle

 

Branching an Existing Network Later

Networks rarely stop growing, but they should not have to be re-built to grow. This saddle bolts no-one's schedule: it fixes an outlet where it is needed and lets the network expand branch by branch as demand advances.

Expand Where the Demand Is

Because the branch sits at the load point, the lateral is short, cheaper and easier to bed than if the whole section were reworked.

Key features

Adds an outlet to an in-service main in place.

Sparks expansion without re-routing existing runs.

Short laterals at the exact point of demand.

Applications

Growing districts fed from an existing main.

Brownfield extensions alongside active pipework.

Installation note

Locate the branch at the demand point, fuse the saddle, connect the lateral and commission the new stub.

Branch Saddle Combinations, Main and Outlet

This page lists every moulded branch saddle combination as a main-and-outlet pair, which is the form the workshop needs once the branch diameter has been fixed by the meter or valve on the drawing. The main is named first in each line and the outlet second, and both tooling generations are included with the model stated, so an extension can be matched to what is already in the ground.

Main dnOutlet dnModel
dn63dn20New
dn90dn25New
dn110dn25New
dn160dn63New
dn63dn25New
dn90dn32New
dn110dn32New
dn180dn32New
dn63dn32New
dn90dn63New
dn110dn63New
dn200dn63New
dn90dn20New
dn110dn20New
dn125dn32New
dn225dn63New
dn63dn32Old
dn125dn63Old
dn250dn90Old
dn315dn110Old
dn90dn63Old
dn160dn63Old
dn250dn110Old
dn110dn63Old
dn200dn90Old
dn315dn90Old

The pattern in the list is deliberate: the outlets scale with the main, so a small main takes the smallest branches and the largest body in the family takes the largest. There is no combination where the outlet approaches the main diameter - for a branch that size a tee or a tapping tee is the correct fitting rather than a saddle, because the clamp needs a sound ring of pipe around the outlet to fuse to. On a live line the saddle is welded with the standard cycle and the branch is then cut through the main wall with the tool supplied for the purpose, so the network stays in service throughout. The outlet-first view and the full schedule are on the electrofusion branch saddle page and the specifications page.

As the factory behind this Electrofusion Branch Saddle, Qingfa Industry controls mould design, injection and final inspection in one place in Yuyao, Ningbo, China. Learn more about our company.

Saddle dimensions: the tapping saddle dimension table lists 16 main-by-branch combinations from dn63 x 20 to dn225 x 63 with the body dimensions L1 to L6.

Hot Tags: Electrofusion Branch Saddle, Electrofusion Branch Saddle dn20-dn180, PE100 electrofusion branch saddle, electrofusion branch saddle supplier, IPS ElectroFusion Branch Saddle HDPE, electrofusion saddle, Electrofusion Tapping Saddle Tee, Electrofusion Branch Saddle, EF Tapping Saddle, HDPE Fusion Saddle

Send Inquiry