Selecting the Electrofusion End Cap Fitting comes down to matching three variables: the dn size of the pipe, the SDR of that pipe, and the joint type. Get those right and the fusion geometry follows on its own.
This page is the decision sequence; the numbers themselves are on the dimensions page.
Step 1: confirm the pipe size and SDR
Measure the pipe outside diameter and read the SDR from the pipe marking. The Electrofusion End Cap Fittings are supplied dn40 to dn315 in SDR11 and SDR17.
| Size band | Wall series | Typical use |
|---|---|---|
| dn40 - dn110 | SDR11 and SDR17 | distribution mains and industrial lines |
| dn125 - dn180 | SDR11 and SDR17 | trunk mains and industrial lines |
| dn200 - dn315 | SDR11 and SDR17 | trunk mains and industrial lines |
If the pipe marking is unreadable, measure the wall at three points round the circumference and divide the outside diameter by the mean wall. For the Electrofusion End Cap Fitting that gives the SDR closely enough to pick the right unit.
Step 2: match the unit to the pipe series
A socket moulded for SDR11 will not close on SDR17 pipe. The socket depth and the fusion zone are set by the wall series, not by the dn size, so the pair has to be matched for the Electrofusion End Cap Fitting.
Where a line mixes series, order the Electrofusion End Cap Fittings against the pipe actually being laid at each joint, not against the nominal size of the run.
Step 3: check the pressure class
Pressure class follows from the wall series and the material grade. Confirm the design pressure of the line before the Electrofusion End Cap Fittings are ordered, because a change of series after moulding is a new tool, not a re-label. The series on offer are SDR11 and SDR17 across dn40 to dn315.
Common selection mistakes
The mistakes below account for most re-quotes on the Electrofusion End Cap Fitting across the dn40 to dn315 range:
- Quoting a dn size without the SDR.
- Mixing unit and pipe from different wall series.
- Assuming one unit suits both electrofusion and butt fusion joints.
- Ordering to an imperial size when the line is metric.
- Choosing on price alone for a line whose design pressure is fixed.
Specifications
Every size held for the HDPE End Cap is listed below with the wall series it is produced in - 11 sizes over dn40 to dn315, SDR 11 only. A dash means that series is not tooled at that size.
| Size (dn) | SDR 11 |
|---|---|
| dn40 | ✓ |
| dn50 | ✓ |
| dn63 | ✓ |
| dn75 | ✓ |
| dn90 | ✓ |
| dn110 | ✓ |
| dn160 | ✓ |
| dn200 | ✓ |
| dn225 | ✓ |
| dn250 | ✓ |
| dn315 | ✓ |
SDR is the outside diameter divided by the wall thickness, so the same dn carries a different wall in each series. SDR 11 only on this product; the pressure classes for PE100 in water service at 20 °C are SDR 9 = PN 20, SDR 11 = PN 16 and SDR 17 = PN 10, and they derate at higher temperatures.
Pressure class by wall series
| SDR | PN at 20 °C, PE100 water | Typical duty |
|---|---|---|
| SDR 11 | PN 16 | standard pressure pipe, gas and water |
Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.
Related pages
Other pages in the Electrofusion End Cap Fitting section, each covering a different angle of the same product family:
-
HDPE Electrofusion Cap
An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range
-
Versatile Electrofusion End Cap
Products Description versatile electrofusion end cap - Main body: One-piece injection molding of PE100 high-density polyethylene, resistant to corrosion and pressure. - Internal: Spiral electric
-
Electrofusion End Cap For Pipe Closure
An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The
-
End Cap
A standard electrofusion end cap for terminating PE pipe simply and reliably. Supplied across a full range of nominal sizes, it welds onto the prepared pipe end with ordinary electrofusion equipment
-
HDPE Electrofusion End Cap 40mm
An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,
-
PE Electrofusion End Cap for Buried Lines
A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to
-
Electrofusion End Cap Sdr11
aling at the...
-
Electrofusion End Cap Pn16
An electrofusion end cap rated to PN16, built to hold a 16 bar working pressure so a dead-end stays sealed during hydrostatic testing and under sustained service load. The cap welds onto the pipe end
-
Electrofusion End Cap Pe100
Products Description electrofusion end cap pe100 Our HDPE electrofusion end caps cover a size range of 40mm-315mm, engineered for reliable sealing of PE pipe systems. Made from premium virgin HDPE,
-
Electrofusion End Cap For Gas
An electrofusion end cap built for gas service, sealing the end of a polyethylene gas main or service without fear of permeation or escaping pockets of fuel. The cap welds to the pipe end with a
-
Electrofusion Test End Cap
An electrofusion test end cap engineered with a blow-out-conscious, vented design that protects crews while a section is placed under test load. Instead of a loose fitting that could shear off under
-
Electrofusion Cap
A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same