Electrofusion End Cap For Pipe Closure
End Cap Dimension Drawing

Sealing the End of a Pipe With an Electrofusion Cap
Every PE line ends somewhere: at a tank, a valve, or a deliberately blanked stub waiting for a future connection. This electrofusion end cap provides that closure, welded directly onto the pipe so the terminal is as strong as the rest of the run.
One Fusion Closes the Line
The cap is slid onto the prepared pipe end and fused in place with standard equipment. The result is a continuous polymer closure with no separate seal ring, clamp or thread that could age, and no path for leakage at the end of the line.
Key features
Welds onto the pipe end for a homogeneous, leak-tight closure.
Suits permanent dead-ends and temporary trial sections.
Barcode-controlled fusion for repeatable, certifiable joints.
Moulded from PE100 for water and gas service.
Applications
Dead-ending a mains run at a chamber or bound.
Blanked branch stubs held ready for later tapping.
Pressure-test closures at the end of a test section.
Temporary sealing during staged installation.
Installation note
Prepare and clean the pipe end, position the cap square to the line, weld, and allow the joint to cool before pressurising or backfilling.
Line Closure Caps, dn40 to dn315
Where a main is capped for good - a spur that will never be extended, or a section taken out of service - the closure is made with a cap at the largest end of the range, because the dead-end load grows with the bore. The four bodies below cover that duty and are all pressed in the heavy wall series, which is what the mains they close are laid in.
| Size | SDR Series | Size | SDR Series | Size | SDR Series |
|---|---|---|---|---|---|
| dn250 | 11 | dn200 | 11 | dn315 | 11 |
| dn225 | 11 |
A permanent closure differs from a temporary one in what it has to resist: the cap takes the full end thrust of the line, so the wall series of the cap has to match the wall series of the pipe and the fusion cycle has to be run to the fitting's own parameters rather than to a shortened cycle for convenience. On the largest two sizes it is worth confirming the anchor arrangement at the dead end, because a capped dn315 main at PN16 develops a thrust that the soil alone will not always hold. The cap itself adds no metal to the line, so a closure made this way needs no cathodic protection and no coating repair. The full range is on the electrofusion end cap page, and the cross-family chart on the specifications page.
Every Electrofusion End Cap For Pipe Closure we ship comes from our own injection lines and is tested in a CNAS-accredited laboratory before despatch. Learn more about our company.
Hot Tags: Electrofusion End Cap For Pipe Closure, Electrofusion End Cap For Pipe Closure dn40-dn315, PE100 electrofusion end cap for pipe closure, electrofusion end cap for pipe closure supplier, HDPE End Cap, End Cap HDPE Pipe, End Cap HDPE, PE PiPE End Cap, Electrofusion Test Cap, HDPE PiPE End Cap