Electrofusion Test Caps are moulded from HDPE and fused to PE pressure pipe. The range covered on this page runs dn40 to dn63 in SDR11 and SDR17. Sizes are quoted as dn, the outside diameter of the pipe in millimetres.
Everything below applies to the Electrofusion Test Cap specifically. The neighbouring pages in this section cover selection, dimensions, installation and the application side separately.
Product range
The Electrofusion Test Cap family covers electrofusion end caps, butt fusion end caps and test caps.
Each type is moulded to the outside diameter of the pipe it joins, so a fitting and its pipe share one fusion geometry. For the Electrofusion Test Cap that means the socket depth and the fusion zone are set by the dn size and the wall series together, not by the fitting type.
Size range and wall series
Sizes for the Electrofusion Test Cap are grouped into bands by the work they do.
| Size band | Wall series | Typical use |
|---|---|---|
| dn40 - dn63 | SDR11 and SDR17 | service and house connections |
Wall series held are SDR11 and SDR17. A unit moulded for one series will not close correctly on pipe of the other, which is the single most common cause of a rejected joint on this product.
Material and marking
Electrofusion Test Caps are moulded from HDPE compound with the lot certificate on file. Each unit carries the dn size, the SDR and the material grade on the body; black compound with a co-extruded stripe is the standard supply.
Do not fuse a Electrofusion Test Cap whose marking cannot be read. If the marking is missing, the unit cannot be matched to a wall series and the joint cannot be qualified.
Applications
Electrofusion Test Caps are used for potable water distribution, gas distribution, industrial process lines, mining dewatering and irrigation. Where the trench is narrow or the pipe cannot be clamped square, this family is chosen over butt fusion because the joint is made from outside the pipe.
For the Electrofusion Test Cap the range that matters in every one of those sectors is dn40 to dn63, and the wall series follows from the design pressure of the line rather than from the sector itself.
Ordering information
Quote the type, the dn size, the SDR of the mating pipe and the destination port. For the Electrofusion Test Cap the size band to state is dn40 to dn63.
Specifications
The table below lists every size held for the HDPE End Cap and the wall series available at each size. The ladder runs dn40 to dn315 - 11 sizes - in SDR 11 only.
| Size (dn) | SDR 11 |
|---|---|
| dn40 | ✓ |
| dn50 | ✓ |
| dn63 | ✓ |
| dn75 | ✓ |
| dn90 | ✓ |
| dn110 | ✓ |
| dn160 | ✓ |
| dn200 | ✓ |
| dn225 | ✓ |
| dn250 | ✓ |
| dn315 | ✓ |
SDR is the outside diameter divided by the wall thickness, so the same dn carries a different wall in each series. SDR 11 only on this product; the pressure classes for PE100 in water service at 20 °C are SDR 9 = PN 20, SDR 11 = PN 16 and SDR 17 = PN 10, and they derate at higher temperatures.
Pressure class by wall series
| Wall series | Pressure class (PE100, water, 20 °C) | Where it is used |
|---|---|---|
| SDR 11 | PN 16 | standard pressure pipe, gas and water |
Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.
Related pages
Other pages in the Electrofusion Test Cap section, each covering a different angle of the same product family:
-
HDPE Electrofusion Cap
An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range
-
Versatile Electrofusion End Cap
Products Description versatile electrofusion end cap - Main body: One-piece injection molding of PE100 high-density polyethylene, resistant to corrosion and pressure. - Internal: Spiral electric
-
Electrofusion End Cap For Pipe Closure
An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The
-
Monolithic End Cap
A monolithic end cap moulded as a single solid piece, so the terminal has no seam, weld line or layer to split apart. The uniform wall thickness and continuous material keep the closure as strong as
-
End Cap
A standard electrofusion end cap for terminating PE pipe simply and reliably. Supplied across a full range of nominal sizes, it welds onto the prepared pipe end with ordinary electrofusion equipment
-
HDPE Electrofusion End Cap 40mm
An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,
-
PE ElectroFusion End Cap
A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to
-
Electrofusion End Cap Sdr11
aling at the...
-
Electrofusion End Cap Pe100
Products Description electrofusion end cap pe100 Our HDPE electrofusion end caps cover a size range of 40mm-315mm, engineered for reliable sealing of PE pipe systems. Made from premium virgin HDPE,
-
Electrofusion End Cap For Gas
An electrofusion end cap built for gas service, sealing the end of a polyethylene gas main or service without fear of permeation or escaping pockets of fuel. The cap welds to the pipe end with a
-
HDPE Electrofusion End Cap
A high-density polyethylene electrofusion end cap that seals the end of PE mains and service lines with a practical balance of strength and low weight. The HDPE construction resists impact from
-
Electrofusion Cap
A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same