The Electrofusion Test End Cap range covers the electrofusion caps used to seal the end of a section while it is pressure tested, moulded from PE100. The range covered on this page runs dn20 to dn160 in SDR11 and SDR17. Sizes are quoted as dn, the outside diameter of the pipe in millimetres.

This page stands on its own rather than covering a size or a variant of another family, so the specification below is complete for the Electrofusion Test End Cap.

Product range

The electrofusion test cap family covers the caps used to seal a section while it is held under test pressure.

This page covers the Electrofusion Test End Cap specifically. The dn ladder, the wall series and the fusion geometry are the family's; what separates one variant from the next is the description it is ordered under and the sizes stocked against it.

Each type is moulded to the outside diameter of the pipe it seals, so a cap and its pipe share one fusion geometry. For the Electrofusion Test End Cap that means the socket depth and the fusion zone are set by the dn size and the wall series together, not by the fitting type.

Size range and wall series

Sizes for the Electrofusion Test End Cap are grouped into bands by the work they do.

Size bandWall seriesTypical use
dn20 - dn63SDR11 and SDR17pressure test plugs on new sections
dn75 - dn160SDR11 and SDR17hydrostatic test sealing on distribution mains

Wall series held are SDR11 and SDR17. A unit moulded for one series will not close correctly on pipe of the other, which is the single most common cause of a rejected joint on the Electrofusion Test End Cap.

Material and marking

Units in the Electrofusion Test End Cap range are moulded from PE100 compound with the lot certificate on file. Each unit carries the dn size, the SDR and the material grade on the body; black compound with a co-extruded stripe is the standard supply.

Do not fuse a Electrofusion Test End Cap whose fusion zone is contaminated, scratched or out of round. Scrape the oxide layer, clean the socket and the pipe end, and keep the joint immobile until the cycle is complete and the cooling time has run.

Applications

Test end caps seal a new section while it is held under pressure, which keeps the test quick to set up on water and gas distribution networks and on industrial process lines.

For the Electrofusion Test End Cap the range that matters in every one of those sectors is dn20 to dn160, and the wall series follows from the design pressure of the line rather than from the sector itself.

Ordering information

Quote the type, the dn size, the SDR of the mating pipe and the test pressure. For the Electrofusion Test End Cap the size band to state is dn20 to dn160.

Specifications

The table below lists every size held for the HDPE End Cap and the wall series available at each size. The ladder runs dn40 to dn315 - 11 sizes - in SDR 11 only.

Nominal sizeSDR 11
dn40✓
dn50✓
dn63✓
dn75✓
dn90✓
dn110✓
dn160✓
dn200✓
dn225✓
dn250✓
dn315✓

Because SDR sets the wall, each series is a separate tool even at the same dn. SDR 11 only in this range. The classes given are PE100, water, 20 °C - see the pressure rating page for the derating factors used on gas and hot-water lines.

Pressure class by wall series

Wall seriesPressure class (PE100, water, 20 °C)Where it is used
SDR 11PN 16standard pressure pipe, gas and water

Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.

Related pages

Catalogue pages worth reading alongside the Electrofusion Test End Cap:

  • Electrofusion Test End Cap

    An electrofusion test end cap engineered with a blow-out-conscious, vented design that protects crews while a section is placed under test load. Instead of a loose fitting that could shear off under

  • Versatile Electrofusion End Cap

    Products Description versatile electrofusion end cap - Main body: One-piece injection molding of PE100 high-density polyethylene, resistant to corrosion and pressure. - Internal: Spiral electric

  • Electrofusion End Cap For Pipe Closure

    An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The

  • Monolithic End Cap

    A monolithic end cap moulded as a single solid piece, so the terminal has no seam, weld line or layer to split apart. The uniform wall thickness and continuous material keep the closure as strong as

  • End Cap

    A standard electrofusion end cap for terminating PE pipe simply and reliably. Supplied across a full range of nominal sizes, it welds onto the prepared pipe end with ordinary electrofusion equipment

  • HDPE Electrofusion End Cap 40mm

    An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,

  • PE ElectroFusion End Cap

    A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to

  • Electrofusion End Cap Sdr11

    aling at the...

  • Electrofusion End Cap Pe100

    Products Description electrofusion end cap pe100 Our HDPE electrofusion end caps cover a size range of 40mm-315mm, engineered for reliable sealing of PE pipe systems. Made from premium virgin HDPE,

  • Electrofusion End Cap For Gas

    An electrofusion end cap built for gas service, sealing the end of a polyethylene gas main or service without fear of permeation or escaping pockets of fuel. The cap welds to the pipe end with a

  • HDPE Electrofusion Cap

    An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range

  • Electrofusion Cap

    A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same

Glenda Williams star star star star star
A company can't go far without a firm belief. The company's belief is to be the industry leader. In order to achieve this goal, they continue to optimize their products' service customers.
Juan Price star star star star star
If it wasn't for my friend's recommendation, I couldn't know such a good supplier.
Debra Ashmore star star star star star
The items arrived really fast, they are great value for money, and I feel the deal is worth it.
Estella Parker star star star star star
High quality service and product quality have to satisfy me!
Jerry Bolin star star star star star
Their products have harmonious colors and multiple crafts to choose from, which is perfect for me.
Daniel Young star star star star star
We have been working with you for many years, you are a trustworthy company and you are innovative and good at learning!
Electrofusion Test End Cap is an end cap that closes a pipe end. Stock sizes run dn20 to dn160 in SDR11 and SDR17. Wall thickness follows the SDR, so the fitting has to be ordered against the same series as the pipe; mixing SDR11 with SDR17 pipe at one joint is the most common ordering mistake on this family. Ordering is by type, dn, the SDR of the mating pipe and the destination port. Related pages on this site: HDPE End Cap 63Mm, HDPE Electrofusion Cap and HDPE Electrofusion End Cap.

Send Inquiry