The End Caps are heat fused. The sequence below is the standard procedure for the End Cap HDPE Pipe; the welding machine manual takes precedence wherever the two differ.
Most joint failures trace back to preparation rather than to the fusion cycle, so the preparation steps carry as much weight as the timed ones.
| Size band | Wall series | Typical use |
|---|---|---|
| dn40 - dn50 | SDR11 and SDR17 | service and house connections |
| dn63 - dn50 | SDR11 and SDR17 | service and house connections |
| dn63 | SDR11 and SDR17 | service and house connections |
Before you start
Prepare the pipe before the End Cap HDPE Pipe joint is opened: these are the checks that decide whether the fusion cycle will be worth running.
- Cut the pipe square and remove the burrs.
- Scrape the oxidation layer off the fusion zone over the full socket depth.
- Mark the insertion depth on the pipe with a marker.
- Keep the pipe ends and the units dry and clean.
- Check that the marking matches the pipe SDR.
The scrape is the step most often skipped when installing the End Cap HDPE Pipe. PE oxidises in daylight, and a joint fused through an oxide layer looks sound and still fails under sustained pressure.
Fusion procedure
- Clamp the pipe in the welding machine.
- Face both ends until they are parallel and clean.
- Match the fusion parameters to the dn size and the SDR.
- Bring the faces to temperature and hold the specified heating time.
- Remove the heater and bring the joint together inside the changeover time.
- Hold under pressure for the full cooling time before moving the pipe.
Changeover time is the window between removing the heater and the faces meeting. It is short by design, so everything needed for the next step of the End Cap HDPE Pipe joint should be within reach before the heater comes out.
Inspection after fusion
On a End Cap HDPE Pipe joint, check that the insertion marks are still visible at the socket edge and that the bead is continuous and even all the way round. A bead that is thin on one side means the faces were not parallel.
Common defects and causes
These are the failures that recur on end cap hdpe pipe installations across the dn40 to dn63 range:
- Cold joint: heating time too short, or changeover time exceeded.
- Brittle bead: material overheated or contaminated.
- Offset joint: pipe not clamped square in the machine.
- Insufficient insertion: depth mark not checked before cooling.
- Contaminated fusion zone: scraping skipped or done with a dirty blade.
Specifications
Sizes and wall series for the HDPE End Cap, taken from the production list rather than from a catalogue summary: 11 sizes across dn40 to dn315, in SDR 11 only.
| Nominal size | SDR 11 |
|---|---|
| dn40 | ✓ |
| dn50 | ✓ |
| dn63 | ✓ |
| dn75 | ✓ |
| dn90 | ✓ |
| dn110 | ✓ |
| dn160 | ✓ |
| dn200 | ✓ |
| dn225 | ✓ |
| dn250 | ✓ |
| dn315 | ✓ |
Because SDR sets the wall, each series is a separate tool even at the same dn. SDR 11 only in this range. The classes given are PE100, water, 20 °C - see the pressure rating page for the derating factors used on gas and hot-water lines.
Pressure class by wall series
| Wall series | Pressure class (PE100, water, 20 °C) | Where it is used |
|---|---|---|
| SDR 11 | PN 16 | standard pressure pipe, gas and water |
Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.
Related pages
Other pages in the End Cap HDPE Pipe section, each covering a different angle of the same product family:
-
Electrofusion Test End Cap
An electrofusion test end cap engineered with a blow-out-conscious, vented design that protects crews while a section is placed under test load. Instead of a loose fitting that could shear off under
-
Versatile Electrofusion End Cap
Products Description versatile electrofusion end cap - Main body: One-piece injection molding of PE100 high-density polyethylene, resistant to corrosion and pressure. - Internal: Spiral electric
-
Electrofusion End Cap For Pipe Closure
An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The
-
End Cap
A standard electrofusion end cap for terminating PE pipe simply and reliably. Supplied across a full range of nominal sizes, it welds onto the prepared pipe end with ordinary electrofusion equipment
-
HDPE Electrofusion End Cap 40mm
An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,
-
PE ElectroFusion End Cap
A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to
-
Electrofusion End Cap Sdr11
aling at the...
-
Electrofusion End Cap Pn16
An electrofusion end cap rated to PN16, built to hold a 16 bar working pressure so a dead-end stays sealed during hydrostatic testing and under sustained service load. The cap welds onto the pipe end
-
Electrofusion End Cap Pe100
Products Description electrofusion end cap pe100 Our HDPE electrofusion end caps cover a size range of 40mm-315mm, engineered for reliable sealing of PE pipe systems. Made from premium virgin HDPE,
-
HDPE Electrofusion End Cap
A high-density polyethylene electrofusion end cap that seals the end of PE mains and service lines with a practical balance of strength and low weight. The HDPE construction resists impact from
-
HDPE Electrofusion Cap
An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range
-
Electrofusion Cap
A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same