HDPE Caps are moulded from PE100 and fused to PE pressure pipe. The range covered on this page runs dn40 to dn315 in SDR11 and SDR17. Sizes are quoted as dn, the outside diameter of the pipe in millimetres.

Everything below applies to the HDPE Cap specifically. The neighbouring pages in this section cover selection, dimensions, installation and the application side separately.

Product range

The HDPE Cap family covers electrofusion end caps, butt fusion end caps and test caps.

Each type is moulded to the outside diameter of the pipe it joins, so a fitting and its pipe share one fusion geometry. For the HDPE Cap that means the socket depth and the fusion zone are set by the dn size and the wall series together, not by the fitting type.

Size range and wall series

Sizes for the HDPE Cap are grouped into bands by the work they do.

Size bandWall seriesTypical use
dn40 - dn63SDR11 and SDR17service and house connections
dn75 - dn160SDR11 and SDR17distribution mains
dn180 - dn315SDR11 and SDR17trunk mains and industrial lines

Wall series held are SDR11 and SDR17. A unit moulded for one series will not close correctly on pipe of the other, which is the single most common cause of a rejected joint on this product.

Material and marking

HDPE Caps are moulded from PE100 compound with the lot certificate on file. Each unit carries the dn size, the SDR and the material grade on the body; black compound with a co-extruded stripe is the standard supply.

Do not fuse a HDPE Cap whose marking cannot be read. If the marking is missing, the unit cannot be matched to a wall series and the joint cannot be qualified.

Applications

HDPE Caps are used for potable water distribution, gas distribution, industrial process lines, mining dewatering and irrigation. Where the trench is narrow or the pipe cannot be clamped square, this family is chosen over butt fusion because the joint is made from outside the pipe.

For the HDPE Cap the range that matters in every one of those sectors is dn40 to dn315, and the wall series follows from the design pressure of the line rather than from the sector itself.

Ordering information

Quote the type, the dn size, the SDR of the mating pipe and the destination port. For the HDPE Cap the size band to state is dn40 to dn315.

Related pages

Other pages in the HDPE Cap section, each covering a different angle of the same product family:

Specifications

This is the working specification for the HDPE End Cap: 11 sizes from dn40 to dn315, each listed against the wall series it is actually tooled in. Read the row for the size on the drawing before the enquiry goes out.

dnSDR 11 available
dn40✓
dn50✓
dn63✓
dn75✓
dn90✓
dn110✓
dn160✓
dn200✓
dn225✓
dn250✓
dn315✓

Wall thickness follows from the series, not from the size: wall = dn / SDR. That is why a body tooled in SDR 11 and one tooled in SDR 17 are separate moulds at the same dn. SDR 11 only here; the PN figures quoted are for PE100 in water at 20 °C and need derating for temperature and for gas duty.

Pressure class by wall series

SDRPN at 20 °C, PE100 waterTypical duty
SDR 11PN 16standard pressure pipe, gas and water

Full size and pressure tables for every family are on the specification library, and the derating figures are on the pressure rating page.

  • HDPE Electrofusion End Cap

    A high-density polyethylene electrofusion end cap that seals the end of PE mains and service lines with a practical balance of strength and low weight. The HDPE construction resists impact from

  • Electrofusion End Cap For Pipe Closure

    An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The

  • Monolithic End Cap

    A monolithic end cap moulded as a single solid piece, so the terminal has no seam, weld line or layer to split apart. The uniform wall thickness and continuous material keep the closure as strong as

  • HDPE Electrofusion End Cap 40mm

    An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,

  • PE ElectroFusion End Cap

    A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to

  • Electrofusion End Cap Sdr11

    aling at the...

  • Electrofusion End Cap Pn16

    An electrofusion end cap rated to PN16, built to hold a 16 bar working pressure so a dead-end stays sealed during hydrostatic testing and under sustained service load. The cap welds onto the pipe end

  • Electrofusion End Cap Pe100

    Products Description electrofusion end cap pe100 Our HDPE electrofusion end caps cover a size range of 40mm-315mm, engineered for reliable sealing of PE pipe systems. Made from premium virgin HDPE,

  • Electrofusion End Cap For Gas

    An electrofusion end cap built for gas service, sealing the end of a polyethylene gas main or service without fear of permeation or escaping pockets of fuel. The cap welds to the pipe end with a

  • Electrofusion Test End Cap

    An electrofusion test end cap engineered with a blow-out-conscious, vented design that protects crews while a section is placed under test load. Instead of a loose fitting that could shear off under

  • HDPE Electrofusion Cap

    An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range

  • Electrofusion Cap

    A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same

David Granado star star star star star
Your delivery was very fast and there was no damage in transit!
Catherine Johnston star star star star star
Super honest and good seller! Thank you!
Dan Anthony star star star star star
I received the goods soon, thank you!
Frances Satter star star star star star
We are very happy to meet such a professional and helpful manufacturer. They produced our special custom products in a very short time. Thank you very much!
Katherine Chandler star star star star star
Arrived, their products are affordable, I chose it after comparing many, and I will come back later.
Victor Tapia star star star star star
I can't say enough about this cooperation: we were very satisfied with the reasonable price, the positive attitude towards the problem and the excellent quality of the product! We hope to have a
YIKA 15KV 22KV 33KV 35KV HDPE Cable Spacer …...

It's Hard Materials different from the silicone insulator. Also called:Modified polyethylene cable spacer or High-Density polyethylene cable spacer.It's a new material for transmission line cable...

China HDPE Cable Spacer supplier, factory, wholesale, price, store...

HDPE CABLE SPACER. Wishpower HDPE Cable Spacers are produced of a proprietary track-resistant high density polyethylene. They are designed for use on overhead electrical...

HDPE Cable Spacer -Winning Electrical Co., Limited - Solution …...

Benefits of using HDPE Cable Spacers 1. Lighter Weight; Excellent Hydrophobicity. 2. Easy Installation, Transportation and Storage. 3. Economic, Low Maintenance, Long Life Span. 4....

HDPE Cable Spacer - arnoldcable...

Quick Details Product Name: HDPE Cable Spacer Model NO.: JHW-22/33CS-01 Brand: Ziyong Color: Gray Certification: CCC, CE, ISO9001 Size of Bearing Capacity: 8000n Connection...

HDPE Distribution Cable Spacers | Vanguard Electric | United States...

4 rows · 1 year warranty. HDPE accessories available, please check charts below. Superior moisture and ......

22-33kV HDPE Cable Spacer Modified Polyethylene …...

The product has spacing function between cable, conductor used in 33kV transmission line, it can prevent conductor effectively from wind swing and wind vibration,and has advantages of corona proof,...

HDPE Cap covers dn40 to dn315 in SDR11 and SDR17 on this page. Wall thickness follows the SDR, so the fitting has to be ordered against the same series as the pipe; mixing SDR11 with SDR17 pipe at one joint is the most common ordering mistake on this family. For a quotation, state the fitting type, the dn size, the pipe SDR and the destination port. Related pages on this site: HDPE Electrofusion Cap, HDPE Electrofusion End Cap and HDPE Pipe Cap.

Send Inquiry