End Cap

End Cap

A standard electrofusion end cap for terminating PE pipe simply and reliably. Supplied across a full range of nominal sizes, it welds onto the prepared pipe end with ordinary electrofusion equipment and provides a smooth, flush closure for trial sections, permanent dead-ends or temporarily blanked outlets.
Send Inquiry

The Reliable Way to Terminate an Electrofusion Line

A pipe that stops needs a proper end, and the end cap is the straightforward answer. Sized to match standard PE fittings, it closes the run with a weld-on cap that needs no threading, no gasket and no special tooling beyond the fusion machine already on site.

Simple by Design

Fewer choices means fewer mistakes. With a clean socket profile and standard fusion interface, the cap installs predictably, so crews spend less time at a dead-end and more time advancing the pipe run.

Key features

Full range of nominal sizes for mains and service lines.

Welds on with standard electrofusion equipment.

Smooth external profile, easy to bed and backfill.

Consistent material and dimensions across the range.

Applications

Trial and pressure-test closures.

Dead-ends on distribution and service lines.

Blanked stubs awaiting a future outlet.

Installation note

Fit onto a cleanly cut pipe end, weld, cool, and the cap is ready for backfill or testing.

End Cap Dimension Drawing

End Cap

 

End Cap Sizes, Electrofusion Range

An end cap ordered under the short name usually means the moulded electrofusion body rather than the fabricated butt fusion one, and the two do not share a size range. The electrofusion cap is pressed from dn40 to dn315 and takes the standard welding cycle; the butt fusion cap is a different fitting, pressed in both wall series and running much further up the range. The moulded sizes are listed below for the short-form enquiry.

SizeSDR SeriesSizeSDR SeriesSizeSDR SeriesSizeSDR Series
dn5011dn6311dn7511dn9011
dn11011dn16011dn20011dn22511
dn25011dn31511

Two facts settle most orders at this point. The cap is moulded in the heavy wall series only - no light-series tool exists for this body at all - so an SDR17 line is closed with the butt fusion version instead. And the fusion socket is machined to match the pipe it closes, wall included, so the cap is bought against the pipe in front of you rather than against a nominal size: the same diameter in a different series needs a different body, and the two will not interchange however alike they look. The full eleven-size range, which runs down to dn40, and the butt fusion closure beside it, are on the electrofusion end cap page and the specifications page.

As the factory behind this End Cap, Qingfa Industry controls mould design, injection and final inspection in one place in Yuyao, Ningbo, China. Explore our PE100 fitting production.

Cap dimensions: the electrofusion end cap dimension table gives the outside diameter D, socket depth L1 and overall length L for dn75 to dn315, and names the four sizes the drawing does not cover.

Hot Tags: End Cap, End Cap dn40-dn315, End Cap SDR17, End Cap dn40-dn315 SDR17, PE100 end cap, end cap supplier, HDPE End Cap, End Cap HDPE Pipe, End Cap HDPE, PE PiPE End Cap, Electrofusion Test Cap, HDPE PiPE End Cap

Send Inquiry