The 12 Inch HDPE Electrofusion Cap covers one size of the Electrofusion Cap family: 12 in, quoted as dn315, the outside diameter of the pipe in millimetres.

This page covers a single size of the Electrofusion Cap family rather than the whole range, so the specification below is narrowed to 12 in.

Product range

The Electrofusion Cap family covers electrofusion end caps and test caps used to close a run.

This page covers the 12 in electrofusion cap specifically. The dn ladder, the wall series and the fusion geometry are the family's; what separates one variant from the next is the description it is ordered under and the sizes stocked against it.

Each type is moulded to the outside diameter of the pipe it joins, so a fitting and its pipe share one fusion geometry. For the 12 in electrofusion cap that means the socket depth and the fusion zone are set by the dn size and the wall series together, not by the fitting type.

Size range and wall series

The 12 Inch HDPE Electrofusion Cap is held as a single size, so the table below states the parameters directly rather than in bands.

Item12 in
Wall series heldSDR11 and SDR17
Fusion typeelectrofusion, embedded resistance wire
Typical usetrunk mains and industrial lines

Wall series held are SDR11 and SDR17. A unit moulded for one series will not close correctly on pipe of the other, which is the single most common cause of a rejected joint on the 12 Inch HDPE Electrofusion Cap.

Material and marking

Units in the 12 Inch HDPE Electrofusion Cap range are moulded from PE100 compound with the lot certificate on file. Each unit carries the dn size, the SDR and the material grade on the body; black compound with a co-extruded stripe is the standard supply.

Do not fuse a 12 Inch HDPE Electrofusion Cap whose fusion zone is contaminated, scratched or out of round. Scrape the oxide layer, clean the socket and the pipe end, and keep the joint immobile until the cycle is complete and the cooling time has run.

Applications

Electrofusion caps close the end of a run without moving the line, which makes them the standard choice for repairs, tie-ins and any joint where a butt fusion machine cannot be positioned: water distribution, gas distribution, industrial process lines, mining dewatering and irrigation.

For the 12 Inch HDPE Electrofusion Cap the size that matters in every one of those sectors is 12 in, and the wall series follows from the design pressure of the line rather than from the sector itself.

Ordering information

Quote the type, the dn size, the SDR of the mating pipe and the destination port. For the 12 Inch HDPE Electrofusion Cap the size to state is 12 in.

Related pages

Catalogue pages worth reading alongside the 12 Inch HDPE Electrofusion Cap:

  • HDPE Electrofusion End Cap

    A high-density polyethylene electrofusion end cap that seals the end of PE mains and service lines with a practical balance of strength and low weight. The HDPE construction resists impact from

  • Versatile Electrofusion End Cap

    Products Description versatile electrofusion end cap - Main body: One-piece injection molding of PE100 high-density polyethylene, resistant to corrosion and pressure. - Internal: Spiral electric

  • Electrofusion End Cap For Pipe Closure

    An electrofusion end cap for closing off the end of a PE pipe run, whether for a permanent dead-end, a temporary condition during installation or a shut outlet kept ready for future connection. The

  • Monolithic End Cap

    A monolithic end cap moulded as a single solid piece, so the terminal has no seam, weld line or layer to split apart. The uniform wall thickness and continuous material keep the closure as strong as

  • HDPE Electrofusion End Cap 40mm

    An HDPE electrofusion end cap sized at 40mm for terminating small-diameter PE service lines and temporary trial sections. The compact cap welds onto a 40mm pipe end with a standard fusion cycle,

  • PE ElectroFusion End Cap

    A PE electrofusion end cap whose material choice does the hard work: polyethylene is chemically resistant, corrosion-free and durable for decades underground. The cap welds onto the PE pipe end to

  • Electrofusion End Cap Sdr11

    aling at the...

  • Electrofusion End Cap Pn16

    An electrofusion end cap rated to PN16, built to hold a 16 bar working pressure so a dead-end stays sealed during hydrostatic testing and under sustained service load. The cap welds onto the pipe end

  • Electrofusion End Cap For Gas

    An electrofusion end cap built for gas service, sealing the end of a polyethylene gas main or service without fear of permeation or escaping pockets of fuel. The cap welds to the pipe end with a

  • Electrofusion Test End Cap

    An electrofusion test end cap engineered with a blow-out-conscious, vented design that protects crews while a section is placed under test load. Instead of a loose fitting that could shear off under

  • HDPE Electrofusion Cap

    An HDPE electrofusion cap offered across a broad size range, so one dependable fitting family covers dead-ends, temporary blanking, transport protection and test closures. Keeping a single cap range

  • Electrofusion Cap

    A versatile electrofusion cap that fits standard PE pipe and welds with ordinary electrofusion equipment, closing a terminal in minutes for dead-ends, protection or tests. Because it uses the same

Michael Wilfong star star star star star
The after-sales staff is very responsible, I am very satisfied!
Fred Cuevas star star star star star
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
Bettina Allard star star star star star
Their team is knowledgeable and willing to help others, with his help, after-sales problems of our products have been solved easily.
Ralph Mahon star star star star star
Come and have a look at this shop. I have recommended it to my friends, classmates, teachers and relatives. The products in this store are of good quality, with a wide variety of products and fast
Van Hudson star star star star star
Their products have harmonious colors and multiple crafts to choose from, which is perfect for me.
Carl Maul star star star star star
This thing is well designed and any quality control measures they use will show up in the final product. I would also be happy to recommend these products to my friends around me.
On this page the end cap that closes a pipe end runs dn315 in SDR11 and SDR17. Every unit carries the dn size, the SDR and the material grade on the body, and a unit whose marking cannot be read cannot be matched to a wall series, which is the usual cause of a rejected joint. Ordering is by type, dn, the SDR of the mating pipe and the destination port. Related pages on this site: Electrofusion End Cap Fitting, End Cap For HDPE Pipe and Electrofusion End Cap.